Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 181

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

In vivo diffusion tensor MRI of the human heart: Reproducibility of breath‐hold and navigator‐based approaches

Open access
Nielles‐Vallespin, Sonia, Mekkaoui, Choukri, Gatehouse, Peter, Reese, Timothy G., Keegan, Jennifer, Ferreira, Pedro F., Collins, Steve, Speier, Peter, Feiweier, Thorsten, de Silva, Ranil, Jackowski, Marcel P., Pennell, Dudley J., Sosnovik, David E., Firmin, David · 2013 · Magnetic Resonance in Medicine

Abstract

The aim of this study was to implement a quantitative in vivo cardiac diffusion tensor imaging (DTI) technique that was robust, reproducible, and feasible to perform in patients with cardiovascular disease. A stimulated‐echo single‐shot echo‐planar imaging (EPI) sequence with zonal excitation and parallel imaging was implemented, together with a novel modification of the prospective navigator (NAV) technique combined with a biofeedback mechanism. Ten volunteers were scanned on two different days, each time with both multiple breath‐hold (MBH) and NAV multislice protocols. Fractional anisotropy (FA), mean diffusivity (MD), and helix angle (HA) fiber maps were created. Comparison of initial and repeat scans showed good reproducibility for both MBH and NAV techniques for FA (P > 0.22), MD (P > 0.15), and HA (P > 0.28). Comparison of MBH and NAV FA (FA MBHday1 = 0.60 ± 0.04, FA NAVday1 = 0.60 ± 0.03, P = 0.57) and MD (MD MBHday1 = 0.8 ± 0.2 × 10−3 mm 2/s, MD NAVday1 = 0.9 ± 0.2 × 10−3 mm 2/s, P = 0.07) values showed no significant differences, while HA values (HA MBHday1Endo = 22 ± 10°, HA MBHday1Mid‐Endo = 20 ± 6°, HA MBHday1Mid‐Epi = −1 ± 6°, HA MBHday1Epi = −17 ± 6°, HA NAVday1Endo = 7 ± 7°, HA NAVday1Mid‐Endo = 13 ± 8°, HA NAVday1Mid‐Epi = −2 ± 7°, HA NAVday1Epi = −14 ± 6°) were significantly different. The scan duration was 20% longer with the NAV approach. Currently, the MBH approach is the more robust in normal volunteers. While the NAV technique still requires resolution of some bulk motion sensitivity issues, these preliminary experiments show its potential for in vivo clinical cardiac diffusion tensor imaging and for delivering high‐resolution in vivo 3D DTI tractography of the heart. Magn Reson Med 70:454–465, 2013. © 2012 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.24488

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Nielles‐Vallespin, S., Mekkaoui, C., Gatehouse, P., Reese, T. G., Keegan, J., Ferreira, P. F., Collins, S., Speier, P., Feiweier, T., de Silva, R., Jackowski, M. P., Pennell, D. J., Sosnovik, D. E., & Firmin, D.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2012-09-21
Volume
70
Issue
2
Pages
454-465
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2122430680
Cited by
181
References
2
FWCI
11.35
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.