Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 186

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Effects of image reconstruction on fiber orientation mapping from multichannel diffusion MRI: Reducing the noise floor using SENSE

Open access
Sotiropoulos, S. N., Moeller, S., Jbabdi, S., Xu, J., Andersson, J. L., Auerbach, E. J., Yacoub, E., Feinberg, D., Setsompop, K., Wald, L. L., Behrens, T. E. J., Ugurbil, K., Lenglet, C.·2013·Magnetic Resonance in Medicine

Abstract

Purpose: To examine the effects of the reconstruction algorithm of magnitude images from multichannel diffusion MRI on fiber orientation estimation. Theory and Methods: It is well established that the method used to combine signals from different coil elements in multichannel MRI can have an impact on the properties of the reconstructed magnitude image. Using a root‐sum‐of‐squares approach results in a magnitude signal that follows an effective noncentral‐χ distribution. As a result, the noise floor, the minimum measurable in the absence of any true signal, is elevated. This is particularly relevant for diffusion‐weighted MRI, where the signal attenuation is of interest. Results: In this study, we illustrate problems that such image reconstruction characteristics may cause in the estimation of fiber orientations, both for model‐based and model‐free approaches, when modern 32‐channel coils are used. We further propose an alternative image reconstruction method that is based on sensitivity encoding (SENSE) and preserves the Rician nature of the single‐channel, magnitude MR signal. We show that for the same k‐space data, root‐sum‐of‐squares can cause excessive overfitting and reduced precision in orientation estimation compared with the SENSE‐based approach. Conclusion: These results highlight the importance of choosing the appropriate image reconstruction method for tractography studies that use multichannel receiver coils for diffusion MRI acquisition. Magn Reson Med 70:1682–1689, 2013. © 2013 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.24623

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 186

Metadata

Authors
Sotiropoulos, S. N., Moeller, S., Jbabdi, S., Xu, J., Andersson, J. L., Auerbach, E. J., Yacoub, E., Feinberg, D., Setsompop, K., Wald, L. L., Behrens, T. E. J., Ugurbil, K., & Lenglet, C.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2013-02-07
Volume
70
Issue
6
Pages
1682-1689
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1529887509
Cited by
186
References
4
FWCI
9.98
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of image reconstruction on fiber orientation mapping from multichannel diffusion MRI: Reducing the noise floor using SENSE. https://app.cochat.ai/papers/10.1002/mrm.24623
The paper
Sotiropoulos, S. N., Moeller, S., Jbabdi, S., Xu, J., Andersson, J. L., Auerbach, E. J., Yacoub, E., Feinberg, D., Setsompop, K., Wald, L. L., Behrens, T. E. J., Ugurbil, K., & Lenglet, C. (2013). Effects of image reconstruction on fiber orientation mapping from multichannel diffusion MRI: Reducing the noise floor using SENSE. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24623

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.