Myelin water mapping by spatially regularized longitudinal relaxographic imaging at high magnetic fields
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Purpose: Magnetic resonance T1‐weighted images are routinely used for human brain segmentation, brain parcellation, and clinical diagnosis of demyelinating diseases. Myelin is thought to influence the longitudinal relaxation commonly described by a mono‐exponential recovery, although reports of bi‐exponential longitudinal relaxation have been published. The purpose of this work was to investigate if a myelin water T1 contribution could be separated in geometrically sampled Look‐Locker trains of low flip angle gradient echoes. Methods: T1 relaxograms from normal human brain were computed by a spatially regularized inverse Laplace transform after estimating the apparent inversion efficiency. Results: With sufficiently long inversion‐time sampling (ca. 5 × T1 of cerebrospinal fluid), the T1 relaxogram revealed a short‐T1 peak (106–225 ms). The apparent fraction of this water component increased in human brain white matter from 8.3% at 3 T, to 11.3% at 4 T and 15.0% at 7 T. The T2* of the short‐T1 peak at 3 T was shorter, 27.9 ± 13.0 ms, than that of the long‐T1 peak, 51.3 ± 5.6 ms. Conclusion: The short‐T1 fraction is interpreted as the water resident in myelin. Its detection is facilitated by longer T1 of axoplasmic water at higher magnetic field. Magn Reson Med 71:375–387, 2014. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oligodendroglia metabolically support axons and contribute to neurodegeneration
Lee, Y., Morrison, B. M., Li, Y., Lengacher, S., Farah, M. H., Hoffman, P. N., Liu, Y., Tsingalia, A., Jin, L., Zhang, P.-W., et al. (2012) · Nature · doi:10.1038/nature11314 · Cited by 1,664
Mechanisms of axon ensheathment and myelin growth
Sherman, D. L., & Brophy, P. J. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1743 · Cited by 668 · cited 1×
“[2] and [3]): (a) 24-channel coil; (b) 8-channel coil; (c) 12-channel coil.”
The energetics of CNS white matter
Harris, J. J., & Attwell, D. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.3430-11.2012 · Cited by 505
Central nervous system myelin: structure, synthesis and assembly
Aggarwal, S., Yurlova, L., & Simons, M. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.06.004 · Cited by 301
Cited by
Myelin and iron concentration in the human brain: a quantitative study of MRI contrast
Stüber, C., Morawski, M., Schäfer, A., Labadie, C., Wähnert, M., Leuze, C., Streicher, M., Barapatre, N., Reimann, K., Geyer, S., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.02.026 · Cited by 635
Self-citationQuantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L. J., Helms, G., Mohammadi, S., & Kirilina, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 300
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin
MacKay, A. L., & Laule, C. (2016) · Brain Plasticity · doi:10.3233/bpl-160033 · Cited by 284
Iron, myelin, and the brain: neuroimaging meets neurobiology
Möller, H. E., Bossoni, L., Connor, J. R., Crichton, R. R., Does, M. D., Ward, R. J., Zecca, L., Zucca, F. A., & Ronen, I. (2019) · Trends in Neurosciences · doi:10.1016/j.tins.2019.03.009 · Cited by 207
Self-citation
Metadata
- Authors
- Labadie, C., Lee, J., Rooney, W. D., Jarchow, S., Aubert‐Frécon, M., Springer, C. S., & Möller, H. E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2013-03-06
- Volume
- 71
- Issue
- 1
- Pages
- 375-387
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1851169357
- Cited by
- 126
- References
- 4
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.