Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Combined saturation/inversion recovery sequences for improved evaluation of scar and diffuse fibrosis in patients with arrhythmia or heart rate variability

Open access
Weingärtner, Sebastian, Akçakaya, Mehmet, Basha, Tamer, Kissinger, Kraig V., Goddu, Beth, Berg, Sophie, Manning, Warren J., Nezafat, Reza·2014·Magnetic Resonance in Medicine

Abstract

Purpose: To develop arrhythmia‐insensitive inversion recovery sequences for improved visualization of myocardial scar and quantification of diffuse fibrosis. Methods: A novel preparation pre‐pulse, called saturation pulse prepared heart‐rate‐independent inversion recovery, is introduced, which consists of a combination of saturation and inversion pulses to remove the magnetization history in each heartbeat in late gadolinium enhancement (LGE) imaging and eliminate the need for rest periods in T1 mapping. The proposed LGE and T1 mapping sequences were evaluated against conventional LGE and modified Look‐Locker inversion sequences using numerical simulations, phantom and imaging in healthy subjects and patients with suspected or known cardiovascular disease. Results: Simulations and phantom experiments show that the saturation pulse prepared heart‐rate‐independent inversion recovery pre‐pulse in LGE reduces ghosting artifacts and results in perfect nulling of the healthy myocardium in the presence of arrhythmia. In T1 mapping, saturation pulse prepared heart‐rate‐independent inversion recovery results in (a) reduced scan time (17 vs. 9 heartbeats), (b) insensitivity to heart rate for long T1, and (c) increased signal homogeneity for short T1. LGE images in a patient in atrial fibrillation during the scan show improved myocardial nulling. In vivo T1 maps demonstrate increased signal homogeneity in blood pools and myocardium. Conclusion: The proposed sequences are insensitive to heart rate variability, yield improved LGE images in the presence of arrhythmias, as well as T1 mapping with shorter scan times. Magn Reson Med 71:1024–1034, 2014. © 2013 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.24761

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 177

Metadata

Authors
Weingärtner, S., Akçakaya, M., Basha, T., Kissinger, K. V., Goddu, B., Berg, S., Manning, W. J., & Nezafat, R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2013-05-06
Volume
71
Issue
3
Pages
1024-1034
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1941558189
Cited by
177
References
2
FWCI
11.17
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.