Magnetic susceptibility induced white matter MR signal frequency shifts—experimental comparison between Lorentzian sphere and generalized Lorentzian approaches
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose: The nature of the remarkable phase contrast in high‐field gradient echo MRI studies of human brain is a subject of intense debates. The generalized Lorentzian approach (He and Yablonskiy, Proc Natl Acad Sci USA 2009;106:13558–13563) provides an explanation for the anisotropy of phase contrast, the near absence of phase contrast between white matter and cerebrospinal fluid, and changes of phase contrast in multiple sclerosis. In this study, we experimentally validate the generalized Lorentzian approach. Theory and Methods: The Generalized Lorentzian Approach suggests that the local contribution to frequency shifts in white matter does not depend on the average tissue magnetic susceptibility (as suggested by Lorentzian sphere approximation), but on the distribution and symmetry of magnetic susceptibility inclusions at the cellular level. We use ex vivo rat optic nerve as a model system of highly organized cellular structure containing longitudinally arranged myelin and neurofilaments. The nerve's cylindrical shape allowed accurate measurement of its magnetic susceptibility and local frequency shifts. Results: We found that the volume magnetic susceptibility difference between nerve and water is −0.116 ppm, and the magnetic susceptibilities of longitudinal components are −0.043 ppm in fresh nerve, and −0.020 ppm in fixed nerve. Conclusion: The frequency shift observed in the optic nerve as a representative of white matter is consistent with generalized Lorentzian approach but inconsistent with Lorentzian sphere approximation. Magn Reson Med 71:1251–1263, 2014. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Layer-specific variation of iron content in cerebral cortex as a source of MRI contrast
Fukunaga, M., Li, T.-Q., van Gelderen, P., de Zwart, J. A., Shmueli, K., Yao, B., Lee, J., Maric, D., Aronova, M. A., Zhang, G., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911177107 · Cited by 408 · cited 2×
“[7] (usually up to second order) for all r and u.”
BackgroundIn vivo assessment of myelination by phase imaging at high magnetic field
Lodygensky, G. A., Marques, J. P., Maddage, R., Perroud, E., Sizonenko, S. V., Hüppi, P. S., & Gruetter, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.057 · Cited by 91
Cited by
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Wisnieff, C., Ramanan, S., Olesik, J., Gauthier, S., Wang, Y., & Pitt, D. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25420 · Cited by 245
“A susceptibility tensor (23,24) can be used to model susceptibility anisotropy observed in ordered myelin that induces orientation dependence of R2*(25), phase (26,27) and apparent susceptibility(23,28–31).”
BackgroundLiu, Z., Spincemaille, P., Yao, Y., Zhang, Y., & Wang, Y. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26946 · Cited by 218
Contributions to magnetic susceptibility of brain tissue
Duyn, J. H., & Schenck, J. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3546 · Cited by 212
Quantitative susceptibility mapping: Report from the 2016 reconstruction challenge
Langkammer, C., Schweser, F., Shmueli, K., Kames, C., Li, X., Guo, L., Milovic, C., Kim, J., Wei, H., Bredies, K., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26830 · Cited by 183
Metadata
- Authors
- Luo, J., He, X., & Yablonskiy, D. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2013-05
- Volume
- 71
- Issue
- 3
- Pages
- 1251-1263
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2098507435
- Cited by
- 48
- References
- 2
- FWCI
- 4.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.