The DOI matches its Crossref record.
Mapping of amide, amine, and aliphatic peaks in the CEST spectra of murine xenografts at 7 T: CEST Mapping in Murine Cancer Xenografts at 7T
Open accessAbstract
PURPOSE: To evaluate the performance of endogenous chemical exchange saturation transfer (CEST) spectra and derived maps in a longitudinal study of tumor xenografts to ascertain the role of CEST parameters in describing tumor progression and in distinguishing between tumor, muscle, and necrosis. METHODS: CEST spectra of 24 mice with tumor xenografts (20 LLC and 4 MDA) were acquired at three time-points. We employed a novel method of decomposing the CEST spectrum into a sum of four Lorentzian shapes, each with a corresponding measured amplitude, width and frequency offset. This semi-quantitative method is an improvement over techniques which simply assess the asymmetry in the spectrum for the presence of CEST, due to the fact that it is not confounded by CEST peaks on opposing sides of the direct effect. The CEST images were compared to several other commonly employed contrast mechanisms: T1 relaxation, T2 relaxation, diffusion (ADC), and magnetization transfer (MT). RESULTS: Tumor spectra had distinct CEST peaks corresponding to the presence of hydrogen exchange between free water and amide, amine, and aliphatic groups. All three CEST peaks (amide, amine, and aliphatic) were larger in the tumor tissue as compared with the adjacent healthy muscle. CONCLUSIONS: CEST contrast (particularly the amine peak amplitude) performed especially well in distinguishing areas of apoptosis and/or necrosis from actively progressing tumor, as validated by histology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
APT‐weighted MRI: Techniques, current neuro applications, and challenging issues
Zhou, J., Heo, H., Knutsson, L., van Zijl, P. C. M., & Jiang, S. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26645 · Cited by 345
van Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
Self-citationZaiss, M., & Bachert, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/r221 · Cited by 323
Magnetic resonance imaging techniques for monitoring glioma response to chemoradiotherapy
Lawrence, L. S. P., Maralani, P. J., Das, S., Sahgal, A., Stanisz, G. J., & Lau, A. Z. (2025) · Journal of Neuro-Oncology · doi:10.1007/s11060-024-04856-3 · Cited by 4
Self-citation
Metadata
- Authors
- Desmond, K. L., Moosvi, F., & Stanisz, G. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2013-06-25
- Volume
- 71
- Issue
- 5
- Pages
- 1841-1853
- ISSN
- 0740-3194 (ISSN-L)
- OpenAlex
- W1592935930
- Cited by
- 198
- References
- 0
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.