Magnetization transfer from inhomogeneously broadened lines: A potential marker for myelin
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Purpose: To characterize a new approach to magnetization transfer (MT) imaging with improved specificity for myelinated tissues relative to conventional MT. Methods: Magnetization transfer preparation sequences were implemented with all radiofrequency power centered on a single frequency and also with power evenly divided between positive and negative frequencies. Dual frequency saturation was achieved both with short, alternating frequency pulses and with sinusoidal modulation of continuous irradiation. Images following preparation were acquired with a single shot fast spin echo sequence. Single and dual frequency preparation should achieve similar saturation of molecules except for those with inhomogenously broadened lines. Inhomogenous MT (IHMT) images were generated by subtraction of dual from single frequency prepared images. IHMT imaging was performed with different power and frequency in the brains of normal volunteers. Results: The IHMT method demonstrated a greater white/gray matter ratio than conventional MT and virtual elimination of signal in scalp and other unmyelinated tissues. IHMT exceeded 5% of the fully relaxed magnetization in white matter. A broad frequency spectrum and signs of axonal angular dependence at high frequency were observed that are consistent with dipolar broadening. Conclusion: IHMT shows promise for myelin‐specific imaging. Further study of physical mechanisms and diagnostic sensitivity are merited. Magn Reson Med 73:614–622, 2015. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cholesterol metabolism in the brain
Dietschy, J. M., & Turley, S. D. (2001) · Current Opinion in Lipidology · doi:10.1097/00041433-200104000-00003 · Cited by 906 · cited 1×
“Myelinated WM has an exceptionally high membrane lipid content (35,36), with 2.”
BackgroundLipid composition of the normal human brain: gray matter, white matter, and myelin
O'Brien, J. S., & Sampson, E. L. (1965) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)39619-x · Cited by 848
Membrane Protein Topology Probed by 1H Spin Diffusion from Lipids Using Solid-State NMR Spectroscopy
Huster, D., Yao, X., & Hong, M. (2002) · Journal of the American Chemical Society · doi:10.1021/ja017001r · Cited by 178
Cited by
The development of brain white matter microstructure
Lebel, C., & Deoni, S. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.097 · Cited by 602
“An extension of MT is inhomogeneous MT (ihMT) (Varma et al., 2015), which exploits a difference between the positive and negative offset signal to improve the sensitivity and selectivity to lipid (e.g., myelin) protons. ihMT contrast within brain white matter is driven by dipolar coupling in lipid…”
BackgroundMagnetic Resonance of Myelin Water: An in vivo Marker for Myelin
MacKay, A. L., & Laule, C. (2016) · Brain Plasticity · doi:10.3233/bpl-160033 · Cited by 284
An interactive meta-analysis of MRI biomarkers of myelin
Mancini, M., Karakuzu, A., Cohen-Adad, J., Cercignani, M., Nichols, T. E., & Stikov, N. (2020) · eLife · doi:10.7554/elife.61523 · Cited by 168
So You Want to Image Myelin Using MRI: An Overview and Practical Guide for Myelin Water Imaging
Lee, J., Hyun, J., Lee, J., Choi, E., Shin, H., Min, K., Nam, Y., Kim, H. J., & Oh, S. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27059 · Cited by 134
“Recently, another type of MT imaging, inhomogeneous MT, has been proposed, targeting myelin.(118) In particular, a new filtering method of inhomogeneous MT that improves specificity to long T1D myelinated structures has shown potential.”
BackgroundPromise and pitfalls of g-ratio estimation with MRI
Campbell, J. S. W., Leppert, I. R., Narayanan, S., Boudreau, M., Duval, T., Cohen-Adad, J., Pike, G. B., & Stikov, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.038 · Cited by 129
Metadata
- Authors
- Varma, G., Duhamel, G., de Bazelaire, C., & Alsop, D. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2014-03-06
- Volume
- 73
- Issue
- 2
- Pages
- 614-622
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1928361585
- Cited by
- 149
- References
- 3
- FWCI
- 6.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetization transfer from inhomogeneously broadened lines: A potential marker for myelin. https://app.cochat.ai/papers/10.1002/mrm.25174
- The paper
- Varma, G., Duhamel, G., de Bazelaire, C., & Alsop, D. C. (2015). Magnetization transfer from inhomogeneously broadened lines: A potential marker for myelin. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.25174
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.