Purpose: The maternal microvasculature of the primate placenta is organized into 10–20 perfusion domains that are functionally optimized to facilitate nutrient exchange to support fetal growth. This study describes a dynamic contrast‐enhanced magnetic resonance imaging method for identifying vascular domains and quantifying maternal blood flow in them. Methods: A rhesus macaque on the 133rd day of pregnancy (G133, term = 165 days) underwent Doppler ultrasound procedures, dynamic contrast‐enhanced magnetic resonance imaging and Cesarean‐section delivery. Serial T 1‐weighted images acquired throughout intravenous injection of a contrast reagent bolus were analyzed to obtain contrast reagent arrival time maps of the placenta. Results: Watershed segmentation of the arrival time map identified 16 perfusion domains. The number and location of these domains corresponded to anatomical cotyledonary units observed following delivery. Analysis of the contrast reagent wave front through each perfusion domain enabled determination of volumetric flow, which ranged from 9.03 to 44.9 mL/s (25.2 ± 10.3 mL/s). These estimates are supported by Doppler ultrasound results. Conclusions: The dynamic contrast‐enhanced magnetic resonance imaging analysis described here provides quantitative estimates of the number of maternal perfusion domains in a primate placenta and estimates flow within each domain. Anticipated extensions of this technique are to the study placental function in non‐human primate models of obstetric complications. Magn Reson Med 73:1570–1578, 2015. © 2014 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.25264

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 64

Metadata

Authors
Frias, A. E., Schabel, M. C., Roberts, V. H. J., Tudorica, A., Grigsby, P. L., Oh, K. Y., & Kroenke, C. D.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2014-04-18
Volume
73
Issue
4
Pages
1570-1578
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1855943475
Cited by
64
References
3
FWCI
4.57
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Using dynamic contrast‐enhanced MRI to quantitatively characterize maternal vascular organization in the primate placenta. https://app.cochat.ai/papers/10.1002/mrm.25264
The paper
Frias, A. E., Schabel, M. C., Roberts, V. H. J., Tudorica, A., Grigsby, P. L., Oh, K. Y., & Kroenke, C. D. (2015). Using dynamic contrast‐enhanced MRI to quantitatively characterize maternal vascular organization in the primate placenta. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.25264

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.