The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Zero TEMR bone imaging in the head
Open accessAbstract
Purpose: To investigate proton density (PD)‐weighted zero TE (ZT) imaging for morphological depiction and segmentation of cranial bone structures. Methods: A rotating ultra‐fast imaging sequence (RUFIS) type ZT pulse sequence was developed and optimized for 1) efficient capture of short T 2 bone signals and 2) flat PD response for soft‐tissues. An inverse logarithmic image scaling (i.e., −log(image)) was used to highlight bone and differentiate it from surrounding soft‐tissue and air. Furthermore, a histogram‐based bias‐correction method was developed for subsequent threshold‐based air, soft‐tissue, and bone segmentation. Results: PD‐weighted ZT imaging in combination with an inverse logarithmic scaling was found to provide excellent depiction of cranial bone structures. In combination with bias correction, also excellent segmentation results were achieved. A two‐dimensional histogram analysis demonstrates a strong, approximately linear correlation between inverse log‐scaled ZT and low‐dose CT for Hounsfield units (HU) between −300 HU and 1,500 HU (corresponding to soft‐tissue and bone). Conclusions: PD‐weighted ZT imaging provides robust and efficient depiction of bone structures in the head, with an excellent contrast between air, soft‐tissue, and bone. Besides structural bone imaging, the presented method is expected to be of relevance for attenuation correction in positron emission tomography (PET)/MR and MR‐based radiation therapy planning. Magn Reson Med 75:107–114, 2016. © 2015 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Samarin, A., Burger, C., Wollenweber, S. D., Crook, D. W., Burger, I. A., Schmid, D. T., von Schulthess, G. K., & Kuhn, F. P. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2113-0 · Cited by 251
Cited by
Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y.-D., Dong, Z., Wang, S.-H., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramirez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 453
Aide, N., Lasnon, C., Veit-Haibach, P., Sera, T., Sattler, B., & Boellaard, R. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3740-2 · Cited by 344
Self-citationPET/MRI: Where might it replace PET/CT?
Ehman, E. C., Johnson, G. B., Villanueva‐Meyer, J. E., Cha, S., Leynes, A. P., Larson, P. E. Z., & Hope, T. A. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25711 · Cited by 271
Mehranian, A., Arabi, H., & Zaidi, H. (2016) · Medical Physics · doi:10.1118/1.4941014 · Cited by 152
Epelbaum, S., Burgos, N., Canney, M., Matthews, D., Houot, M., Santin, M. D., Desseaux, C., Bouchoux, G., Stroer, S., Martin, C., et al. (2022) · Alzheimer's Research & Therapy · doi:10.1186/s13195-022-00981-1 · Cited by 72
Metadata
- Authors
- Wiesinger, F., Sacolick, L. I., Menini, A., Kaushik, S. S., Ahn, S., Veit‐Haibach, P., Delso, G., & Shanbhag, D. D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2015-01-16
- Volume
- 75
- Issue
- 1
- Pages
- 107-114
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1589035167
- Cited by
- 242
- References
- 2
- FWCI
- 17.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Zero TEMR bone imaging in the head. https://app.cochat.ai/papers/10.1002/mrm.25545
- The paper
- Wiesinger, F., Sacolick, L. I., Menini, A., Kaushik, S. S., Ahn, S., Veit‐Haibach, P., Delso, G., & Shanbhag, D. D. (2016). Zero TEMR bone imaging in the head. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.25545
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.