CoChat

Test‐retest reproducibility of neurochemical profiles with short‐echo, single‐voxel MR spectroscopy at 3T and 7T

Open access
Terpstra, Melissa, Cheong, Ian, Lyu, Tianmeng, Deelchand, Dinesh K., Emir, Uzay E., Bednařík, Petr, Eberly, Lynn E., Öz, Gülin · 2016 · Magnetic Resonance in Medicine
Cited by 161

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose: To determine the test‐retest reproducibility of neurochemical concentrations obtained with a highly optimized, short‐echo, single‐voxel proton MR spectroscopy (MRS) pulse sequence at 3T and 7T using state‐of‐the‐art hardware. Methods: A semi‐LASER sequence (echo time = 26–28 ms) was used to acquire spectra from the posterior cingulate and cerebellum at 3T and 7T from six healthy volunteers who were scanned four times weekly on both scanners. Spectra were quantified with LCModel. Results: More neurochemicals were quantified with mean Cramér‐Rao lower bounds (CRLBs) ≤20% at 7T than at 3T despite comparable frequency‐domain signal‐to‐noise ratio. Whereas CRLBs were lower at 7T (P < 0.05), between‐session coefficients of variance (CVs) were comparable at the two fields with 64 transients. Five metabolites were quantified with between‐session CVs ≤5% at both fields. Analysis of subspectra showed that a minimum achievable CV was reached with a lower number of transients at 7T for multiple metabolites and that between‐session CVs were lower at 7T than at 3T with fewer than 64 transients. Conclusion: State‐of‐the‐art MRS methodology allows excellent reproducibility for many metabolites with 5‐min data averaging on clinical 3T hardware. Sensitivity and resolution advantages at 7T are important for weakly represented metabolites, short acquisitions, and small volumes of interest. Magn Reson Med 76:1083–1091, 2016. © 2015 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.26022

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • The role of the posterior cingulate cortex in cognition and disease

    Leech, R., & Sharp, D. J. (2014) · Brain · doi:10.1093/brain/awt162 · Cited by 2,247 · cited 1×

    “We focused on two brain regions that are of interest for neurological diseases and that present different levels of technical challenges for MRS: the posterior cingulate, a key node in the default mode network (25), which is affected in a number of neurological and psychiatric disorders (26,27), and the cerebellum, wh…”
    Background
  • Default-mode brain dysfunction in mental disorders: A systematic review

    Broyd, S. J., Demanuele, C., Debener, S., Helps, S. K., James, C. J., & Sonuga-Barke, E. J. S. (2009) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2008.09.002 · Cited by 1,675 · cited 1×

    “We focused on two brain regions that are of interest for neurological diseases and that present different levels of technical challenges for MRS: the posterior cingulate, a key node in the default mode network (25), which is affected in a number of neurological and psychiatric disorders (26,27), and the cerebellum, wh…”
    Background

Cited by

See all 161

Metadata

Authors
Terpstra, M., Cheong, I., Lyu, T., Deelchand, D. K., Emir, U. E., Bednařík, P., Eberly, L. E., & Öz, G.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2015-10-26
Volume
76
Issue
4
Pages
1083-1091
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1840945875
Cited by
161
References
2
FWCI
8.13
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.