Feasibility of quantitative regional ventilation and perfusion mapping with phase‐resolved functional lung (PREFUL) MRI in healthy volunteers and COPD, CTEPH, and CF patients
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Purpose: In this feasibility study, a phase‐resolved functional lung imaging postprocessing method for extraction of dynamic perfusion (Q) and ventilation (V) parameters using a conventional 1H lung MRI Fourier decomposition acquisition is introduced. Methods: Time series of coronal gradient‐echo MR images with a temporal resolution of 288 to 324 ms of two healthy volunteers, one patient with chronic thromboembolic hypertension, one patient with cystic fibrosis, and one patient with chronic obstructive pulmonary disease were acquired at 1.5 T. Using a sine model to estimate cardiac and respiratory phases of each image, all images were sorted to reconstruct full cardiac and respiratory cycles. Time to peak (TTP), V/Q maps, and fractional ventilation flow‐volume loops were calculated. Results: For the volunteers, homogenous ventilation and perfusion TTP maps (V‐TTP, Q‐TTP) were obtained. The chronic thromboembolic hypertension patient showed increased perfusion TTP in hypoperfused regions in visual agreement with dynamic contrast‐enhanced MRI, which improved postpulmonary endaterectomy surgery. Cystic fibrosis and chronic obstructive pulmonary disease patients showed a pattern of increased V‐TTP and Q‐TTP in regions of hypoventilation and decreased perfusion. Fractional ventilation flow‐volume loops of the chronic obstructive pulmonary disease patient were smaller in comparison with the healthy volunteer, and showed regional differences in visual agreement with functional small airways disease and emphysema on CT. Conclusions: This study shows the feasibility of phase‐resolved functional lung imaging to gain quantitative information regarding regional lung perfusion and ventilation without the need for ultrafast imaging, which will be advantageous for future clinical translation. Magn Reson Med 79:2306–2314, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
He, K., Sun, J., & Tang, X. (2013) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2012.213 · Cited by 5,546
A reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796
Nadaraya, E. A. (1964) · Theory of Probability & Its Applications · doi:10.1137/1109020 · Cited by 3,462
Watson, G. S. (1964) · PUB – Publications at Bielefeld University (Bielefeld University) · Cited by 2,661
Galbán, C. J., Han, M. K., Boes, J. L., Chughtai, K. A., Meyer, C. R., Johnson, T. D., Galbán, S., Rehemtulla, A., Kazerooni, E. A., Martinez, F. J., et al. (2012) · Nature Medicine · doi:10.1038/nm.2971 · Cited by 813
Stahl, M., Wielpütz, M. O., Graeber, S. Y., Joachim, C., Sommerburg, O., Kauczor, H.-U., Puderbach, M., Eichinger, M., & Mall, M. A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0893oc · Cited by 213
Hueper, K., Vogel-Claussen, J., Parikh, M. A., Austin, J. H. M., Bluemke, D. A., Carr, J., Choi, J., Goldstein, T. A., Gomes, A. S., Hoffman, E. A., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201411-2120oc · Cited by 179
Self-citationZapke, M., Topf, H., Zenker, M., Kuth, R., Deimling, M., Kreisler, P., Rauh, M., Chefd’hotel, C., Geiger, B., & Rupprecht, T. (2006) · Respiratory Research · doi:10.1186/1465-9921-7-106 · Cited by 114 · cited 2×
“The FV for each time point during the respiratory cycle is calculated according to Equation [4]; and 8.”
MethodFischer, A., Weick, S., Ritter, C. O., Beer, M., Wirth, C., Hebestreit, H. U., Jakob, P. M., Hahn, D., Bley, T. A., & Köstler, H. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3134 · Cited by 103
Léderlin, M., Bauman, G., Eichinger, M., Dinkel, J., Brault, M., Biederer, J., & Puderbach, M. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.12.003 · Cited by 71
Cited by
Hatabu, H., Ohno, Y., Gefter, W. B., Parraga, G., Madore, B., Lee, K. S., Altes, T. A., Lynch, D. A., Mayo, J. R., Seo, J. B., et al. (2020) · Radiology · doi:10.1148/radiol.2020201138 · Cited by 198
Metadata
- Authors
- Voskrebenzev, A., Gutberlet, M., Klimeš, F., Kaireit, T. F., Schönfeld, C., Rotärmel, A., Wacker, F., & Vogel‐Claussen, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2017-08-30
- Volume
- 79
- Issue
- 4
- Pages
- 2306-2314
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2751039798
- Cited by
- 233
- References
- 17
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Feasibility of quantitative regional ventilation and perfusion mapping with phase‐resolved functional lung (PREFUL) MRI in healthy volunteers and COPD, CTEPH, and CF patients. https://app.cochat.ai/papers/10.1002/mrm.26893
- The paper
- Voskrebenzev, A., Gutberlet, M., Klimeš, F., Kaireit, T. F., Schönfeld, C., Rotärmel, A., Wacker, F., & Vogel‐Claussen, J. (2018). Feasibility of quantitative regional ventilation and perfusion mapping with phase‐resolved functional lung (PREFUL) MRI in healthy volunteers and COPD, CTEPH, and CF patients. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.26893
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.