Localized bioimpedance analysis in the evaluation of neuromuscular disease
The DOI matches its Crossref record.
Abstract
Localized bioimpedance analysis is a novel, noninvasive technique with potential application to neuromuscular disease. In this procedure, high‐frequency alternating current is passed through muscle, and parameters related to the consequent voltage pattern are evaluated. Currents flowing perpendicular to muscle fibers encounter many more cell membranes than do currents flowing parallel to them, producing surface voltage patterns that are altered by disease. Using this technique, 45 normal subjects and 25 patients with various neuromuscular diseases were studied, including 4 with amyotrophic lateral sclerosis, 4 with inflammatory myopathy, and 11 with inclusion‐body myositis. Two parameters, the spatially averaged phase and the effective longitudinal resistivity, were altered in patients with neuromuscular disease. Reductions in phase correlated to disease progression, whereas normalization of phase correlated with disease remission. In patients with inclusion‐body myositis, a unique pattern of reduced phase and elevated resistivity was identified. These findings suggest that localized bioimpedance analysis has the potential of playing a substantial role in the diagnostic and therapeutic evaluation of neuromuscular disease. © 2002 Wiley Periodicals, Inc. Muscle Nerve 25: 000–000, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
“K yle et al. 1444 A R TIC LE IN PR ES S Desport et al.97 ALS 20 TBW100 18O Vache et al.119 Analycor3 0.7671.85 Acceptable estimation of TBW for TBW100; less accurate and concordant at TBW50 B TBW50 1.2171.89 Rutkove et al.98 Neuro-muscular disease 45 cont, 25 pt RJL Phase angle reductions correlated with disease progr…”
BackgroundInfluentialKhalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
“[61], introduced localized bioimpedance analysis as a trending diagnostic tool for neuromuscular disorders.”
BackgroundMeasurement of muscle mass in sarcopenia: from imaging to biochemical markers
Tosato, M., Marzetti, E., Cesari, M., Savera, G., Miller, R. R., Bernabei, R., Landi, F., & Calvani, R. (2017) · Aging Clinical and Experimental Research · doi:10.1007/s40520-016-0717-0 · Cited by 320
Lukaski, H. C. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.149 · Cited by 303
Metadata
- Authors
- Rutkove, S. B., Aaron, R., & Shiffman, C. A.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 2002-02-19
- Volume
- 25
- Issue
- 3
- Pages
- 390-397
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W2104105823
- Cited by
- 149
- References
- 0
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Localized bioimpedance analysis in the evaluation of neuromuscular disease. https://app.cochat.ai/papers/10.1002/mus.10048
- The paper
- Rutkove, S. B., Aaron, R., & Shiffman, C. A. (2002). Localized bioimpedance analysis in the evaluation of neuromuscular disease. Muscle & Nerve. https://doi.org/10.1002/mus.10048
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.