Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 406

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Processed allografts and type I collagen conduits for repair of peripheral nerve gaps

Whitlock, Elizabeth L., Tuffaha, Sami H., Luciano, Janina P., Yan, Ying, Hunter, Daniel A., Magill, Christina K., Moore, Amy M., Tong, Alice Y., Mackinnon, Susan E., Borschel, Gregory H.·2009·Muscle & Nerve

Abstract

Autografting is the gold standard in the repair of peripheral nerve injuries that are not amenable to end‐to‐end coaptation. However, because autografts result in donor‐site defects and are a limited resource, an effective substitute would be valuable. In a rat model, we compared isografts with Integra NeuraGen® (NG) nerve guides, which are a commercially available type I collagen conduit, with processed rat allografts comparable to AxoGen's Avance® human decellularized allograft product. In a 14‐mm sciatic nerve gap model, isograft was superior to processed allograft, which was in turn superior to NG conduit at 6 weeks postoperatively (P < 0.05 for number of myelinated fibers both at midgraft and distal to the graft). At 12 weeks, these differences were no longer apparent. In a 28‐mm graft model, isografts again performed better than processed allografts at both 6 and 22 weeks; regeneration through the NG conduit was often insufficient for analysis in this long graft model. Functional tests confirmed the superiority of isografts, although processed allografts permitted successful reinnervation of distal targets not seen in the NG conduit groups. Processed allografts were inherently non‐immunogenic and maintained some internal laminin structure. We conclude that, particularly in a long gap model, nerve graft alternatives fail to confer the regenerative advantages of an isograft. However, AxoGen processed allografts are superior to a currently available conduit‐style nerve guide, the Integra NeuraGen®. They provide an alternative for reconstruction of short nerve gaps where a conduit might otherwise be used. Muscle Nerve, 2008

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mus.21220

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 406

Metadata

Authors
Whitlock, E. L., Tuffaha, S. H., Luciano, J. P., Yan, Y., Hunter, D. A., Magill, C. K., Moore, A. M., Tong, A. Y., Mackinnon, S. E., & Borschel, G. H.
Venue
Muscle & Nerve
Publisher
Wiley
Published
2009-03-16
Volume
39
Issue
6
Pages
787-799
ISSN
  • 0148-639X (ISSN-L)
  • 1097-4598
OpenAlex
W1968542406
Cited by
406
References
33
FWCI
9.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Processed allografts and type I collagen conduits for repair of peripheral nerve gaps. https://app.cochat.ai/papers/10.1002/mus.21220
The paper
Whitlock, E. L., Tuffaha, S. H., Luciano, J. P., Yan, Y., Hunter, D. A., Magill, C. K., Moore, A. M., Tong, A. Y., Mackinnon, S. E., & Borschel, G. H. (2009). Processed allografts and type I collagen conduits for repair of peripheral nerve gaps. Muscle & Nerve. https://doi.org/10.1002/mus.21220

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.