Reliability of panoramic ultrasound imaging to simultaneously examine muscle size and quality of the medial gastrocnemius
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Introduction: In this study we examined the test–retest reliability of panoramic brightness‐mode ultrasound (US) imaging to simultaneously measure both muscle size and quality from a single US image. Methods: Sixteen healthy, recreationally active men (age = 20.9 ± 2.5 years) volunteered for this investigation. Test–retest reliability was evaluated using intraclass correlation coefficients (ICCs) and the standard error of measurement as a percentage of the mean (SEM%). Muscle size [cross‐sectional area (CSA)], and muscle quality [echo intensity (EI)] of the medial gastrocnemius were examined on 2 separate days. Results: These measures demonstrated acceptable reliability between assessment days with ICCs and SEM% of 0.914 and 0.720 and 5.830 and 3.680 for CSA and EI, respectively. Conclusions: These results suggest that panoramic US imaging may be a reliable technique for simultaneous assessment of both muscle size and quality from a single US scan. Muscle Nerve 49: 736–740, 2014
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635 · cited 2×
“Model 2,1 was used to calculate ICCs, because it has been suggested that the ICCs generated with this model can be generalized to other laboratories and testers.24 The SEM for model 2,1 was calculated from the equation presented by Hopkins.25 All data were analyzed using a custom-written software program (Microsoft Ex…”
MethodLongitudinal study of muscle strength, quality, and adipose tissue infiltration
Delmonico, M. J., Harris, T. B., Visser, M., Park, S. W., Conroy, M. B., Velasquez-Mieyer, P., Boudreau, R., Manini, T. M., Nevitt, M., Newman, A. B., et al. (2009) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2009.28047 · Cited by 1,446
Goodpaster, B. H., Kelley, D. E., Thaete, F. L., He, J., & Ross, R. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.1.104 · Cited by 947
Skeletal muscle sonography: a correlative study of echogenicity and morphology
Reimers, K., Reimers, C. D., Wagner, S., Paetzke, I., & Pongratz, D. E. (1993) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1993.12.2.73 · Cited by 385
Lang, T., Cauley, J. A., Tylavsky, F., Bauer, D., Cummings, S., & Harris, T. B. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.090807 · Cited by 371
Cited by
Imaging of sarcopenia: old evidence and new insights
Albano, D., Messina, C., Vitale, J., & Sconfienza, L. M. (2020) · European Radiology · doi:10.1007/s00330-019-06573-2 · Cited by 400
Sarcopenia: Current Concepts and Imaging Implications
Boutin, R. D., Yao, L., Canter, R. J., & Lenchik, L. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.15.14635 · Cited by 323
Application of ultrasound for muscle assessment in sarcopenia: towards standardized measurements
Perkisas, S., Baudry, S., Bauer, J., Beckwée, D., De Cock, A.-M., Hobbelen, H., Jager-Wittenaar, H., Kasiukiewicz, A., Landi, F., Marco, E., et al. (2018) · European Geriatric Medicine · doi:10.1007/s41999-018-0104-9 · Cited by 255
Damas, F., Libardi, C. A., & Ugrinowitsch, C. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3792-9 · Cited by 254
Fragala, M. S., Kenny, A. M., & Kuchel, G. A. (2015) · Sports Medicine · doi:10.1007/s40279-015-0305-z · Cited by 246
“Ultrasound has been shown to be a reliable tool for assessing muscle quality as echo intensity [143, 144] (a proxy of muscle composition), which may be considered an index of muscle quality.”
Method
Metadata
- Authors
- Rosenberg, J. G., Ryan, E. D., Sobolewski, E. J., Scharville, M. J., Thompson, B. J., & King, G. E.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 2014-04-16
- Volume
- 49
- Issue
- 5
- Pages
- 736-740
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W2136563421
- Cited by
- 106
- References
- 6
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.