The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Measurement of intramuscular fat by muscle echo intensity
Open accessAbstract
Introduction: The aim of this study was to compare ultrasound echo intensity (EI) with high‐resolution T 1‐weighted MRI and to establish calibration equations to estimate percent intramuscular fat from EI. Methods: Thirty‐one participants underwent both ultrasound and MRI testing of 4 muscles: rectus femoris (RF); biceps femoris (BF); tibialis anterior (TA); and medial gastrocnemius (MG). Results: Strong correlations were found between MRI percent fat and muscle EI after correcting for subcutaneous fat thickness (r = 0.91 in RF, r = 0.80 in BF, r = 0.80 in TA, r = 0.76 in MG). Three types of calibration equations were established. Conclusions: Muscle ultrasound is a practical and reproducible method that can be used as an imaging technique for examination of percent intramuscular fat. Future ultrasound studies are needed to establish equations for other muscle groups to enhance its use in both research and clinical settings. Muscle Nerve 52: 963–971, 2015
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Poirier, P., Giles, T. D., Bray, G. A., Hong, Y., Stern, J. S., Pi-Sunyer, F. X., & Eckel, R. H. (2006) · Circulation · doi:10.1161/circulationaha.106.171016 · Cited by 3,165
Obesity, Regional Body Fat Distribution, and the Metabolic Syndrome in Older Men and Women
Goodpaster, B. H., Krishnaswami, S., Harris, T. B., Katsiaras, A., Kritchevsky, S. B., Simonsick, E. M., Nevitt, M., Holvoet, P., & Newman, A. B. (2005) · Archives of Internal Medicine · doi:10.1001/archinte.165.7.777 · Cited by 637
Skeletal muscle sonography: a correlative study of echogenicity and morphology
Reimers, K., Reimers, C. D., Wagner, S., Paetzke, I., & Pongratz, D. E. (1993) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1993.12.2.73 · Cited by 385
Cited by
Advances in muscle health and nutrition: A toolkit for healthcare professionals
Prado, C. M., Landi, F., Chew, S. T. H., Atherton, P. J., Molinger, J., Ruck, T., & Gonzalez, M. C. (2022) · Clinical Nutrition · doi:10.1016/j.clnu.2022.07.041 · Cited by 237
Damas, F., Phillips, S. M., Lixandrão, M. E., Vechin, F. C., Libardi, C. A., Roschel, H., Tricoli, V., & Ugrinowitsch, C. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-015-3243-4 · Cited by 202
Skeletal Muscle Assessment Using Quantitative Ultrasound: A Narrative Review
Ashir, A., Jerban, S., Barrère, V., Wu, Y., Shah, S. B., Andre, M. P., & Chang, E. Y. (2023) · Sensors · doi:10.3390/s23104763 · Cited by 57
Komforti, D., Joffe, C., Magras, A., Peller, A., Garbe, E., Garib, R., Trapuzzano, A., Dawson, N., & Stock, M. S. (2021) · Aging Clinical and Experimental Research · doi:10.1007/s40520-020-01596-y · Cited by 25
The double-edged role of FASII regulator FabT in Streptococcus pyogenes infection
Lambert, C., Gaillard, M., Wongdontree, P., Bachmann, C., Hautcoeur, A., Gloux, K., Guilbert, T., Méhats, C., Prost, B., Solgadi, A., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-52637-3 · Cited by 8
Metadata
- Authors
- Young, H., Jenkins, N. T., Zhao, Q., & Mccully, K. K.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 2015-09-07
- Volume
- 52
- Issue
- 6
- Pages
- 963-971
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W1571673129
- Cited by
- 446
- References
- 3
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of intramuscular fat by muscle echo intensity. https://app.cochat.ai/papers/10.1002/mus.24656
- The paper
- Young, H., Jenkins, N. T., Zhao, Q., & Mccully, K. K. (2015). Measurement of intramuscular fat by muscle echo intensity. Muscle & Nerve. https://doi.org/10.1002/mus.24656
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.