Microneurography for the recording and selective stimulation of afferents: An assessment
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to examine whether a microneurography electrode could record from and then selectively stimulate the same afferent fiber in cat sural and tibial nerves. Fiber activity was recorded distally with microneurography needle electrodes and proximally with hook electrodes. Records from the hook electrodes allowed the waveform shape and latency following natural stimulation to be compared with that produced by electrical stimuli delivered through the needle electrode. The action potentials from approximately 50% of the recorded fibers failed to propagate beyond the needle electrode. When propagation did occur and the comparison could be made, only 25% of the afferents recorded could be selectively stimulated. This relatively low success rate suggests that a typical microneurography needle is not particularly good for selectively stimulating identified afferents. Thus in human experiments, attempts to microstimulate identified afferents may often include stimulation of unidentified alternative, or additional, afferent fibers at thresholds of sensory perception.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
Vallbo, A. B., Hagbarth, K. E., Torebjork, H. E., & Wallin, B. G. (1979) · Physiological Reviews · doi:10.1152/physrev.1979.59.4.919 · Cited by 1,507
Johansson, R. S., & Vallbo, A. B. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012619 · Cited by 1,291
Ochoa, J., & Torebjörk, E. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014873 · Cited by 467
Discharge characteristics of human muscle afferents during muscle stretch and contraction
Hagbarth, K.-E., & Vallbo, Å. B. (1968) · Experimental Neurology · doi:10.1016/0014-4886(68)90156-8 · Cited by 204
Cited by
SENSE AND THE SINGLE NEURON: Probing the Physiology of Perception
Parker, A. J., & Newsome, W. T. (1998) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.21.1.227 · Cited by 801
Does the nervous system use equilibrium-point control to guide single and multiple joint movements?
Bizzi, E., Hogan, N., Mussa-Ivaldi, F. A., & Giszter, S. (1992) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00072538 · Cited by 465
Does the nervous system depend on kinesthetic information to control natural limb movements?
Gandevia, S. C., & Burke, D. (1992) · Behavioral and Brain Sciences · doi:10.1017/s0140525x0007254x · Cited by 359
The representation of egocentric space in the posterior parietal cortex
Stein, J. F. (1992) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00072605 · Cited by 339
Macefield, G., Gandevia, S. C., & Burke, D. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp018247 · Cited by 274
Metadata
- Authors
- Calancie, B. M., & Stein, R. B.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 1988-06
- Volume
- 11
- Issue
- 6
- Pages
- 638-644
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W2040421903
- Cited by
- 49
- References
- 4
- FWCI
- 0.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microneurography for the recording and selective stimulation of afferents: An assessment. https://app.cochat.ai/papers/10.1002/mus.880110617
- The paper
- Calancie, B. M., & Stein, R. B. (1988). Microneurography for the recording and selective stimulation of afferents: An assessment. Muscle & Nerve. https://doi.org/10.1002/mus.880110617
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.