Acoustic and surface EMG diagnosis of pediatric muscle disease
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The ratio of acoustic myography (AMG) amplitude to surface electromyography (EMG) amplitude is proposed as a measure of mechanical output compared with electrical activity of the contractile system. AMG to EMG ratios were measured from 16 children with muscle disease diagnosed by clinical criteria, EMG, and/or muscle biopsy. These were compared with the ratios from 11 normal volunteers spanning the same age range (7‐16 years). AMG to EMG ratios were significantly (P > 0.01) different for the two populations. Using a linear discriminant function to define the normal range for AMG to EMG ratios yielded a sensitivity of 82% (13 of 16 abnormals diagnosed) and a specificity of 91% (10 of 11 normals). These findings suggest that surface recordings may provide significant diagnostic information in muscle disease. The accuracy may be improved further by using additional muscles (e.g., paraspinals) and evoked twitches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acoustic myography: A noninvasive monitor of motor unit fatigue
Barry, D. T., Geiringer, S. R., & Ball, R. D. (1985) · Muscle & Nerve · doi:10.1002/mus.880080303 · Cited by 208
Self-citation
Cited by
Coordination of mastication and swallowing
Palmer, J. B., Rudin, N. J., Lara, G., & Crompton, A. W. (1992) · Dysphagia · doi:10.1007/bf02493469 · Cited by 430
Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces
Saponas, T. S., Tan, D. S., Morris, D., & Balakrishnan, R. (2008) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1357054.1357138 · Cited by 275
Muscle fatigue measured with evoked muscle vibrations
Barry, D. T., Hill, T., & Im, D. (1992) · Muscle & Nerve · doi:10.1002/mus.880150308 · Cited by 62
Self-citationFacilitating Bodily Insights Using Electromyography-Based Biofeedback during Physical Activity
Karolus, J., Bachmann, F., Kosch, T., Schmidt, A., & Woźniak, P. W. (2021) · Proceedings of the 23rd International Conference on Mobile Human-Computer Interaction · doi:10.1145/3447526.3472027 · Cited by 25
“While EMG has its main area of application in clinical settings for diagnostics and prosthetic control [5, 30], the last two decades have shown the feasibility of interactive systems leveraging EMG-based interaction in the domain on human-computer interaction (HCI).”
BackgroundImprecise but Fun: Playful Interaction Using Electromyography
Karolus, J., Thanheiser, S., Peterson, D., Viot, N., Kosch, T., Schmidt, A., & Wozniak, P. W. (2022) · Proceedings of the ACM on Human-Computer Interaction · doi:10.1145/3546725 · Cited by 11
Metadata
- Authors
- Barry, D. T., Gordon, K. E., & Hinton, G. G.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 1990-04
- Volume
- 13
- Issue
- 4
- Pages
- 286-290
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W2139685000
- Cited by
- 124
- References
- 1
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acoustic and surface EMG diagnosis of pediatric muscle disease. https://app.cochat.ai/papers/10.1002/mus.880130403
- The paper
- Barry, D. T., Gordon, K. E., & Hinton, G. G. (1990). Acoustic and surface EMG diagnosis of pediatric muscle disease. Muscle & Nerve. https://doi.org/10.1002/mus.880130403
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.