The DOI matches its Crossref record.
Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces
Abstract
We explore the feasibility of muscle-computer interfaces (muCIs): an interaction methodology that directly senses and decodes human muscular activity rather than relying on physical device actuation or user actions that are externally visible or audible. As a first step towards realizing the mu-CI concept, we conducted an experiment to explore the potential of exploiting muscular sensing and processing technologies for muCIs. We present results demonstrating accurate gesture classification with an off-the-shelf electromyography (EMG) device. Specifically, using 10 sensors worn in a narrow band around the upper forearm, we were able to differentiate position and pressure of finger presses, as well as classify tapping and lifting gestures across all five fingers. We conclude with discussion of the implications of our results for future muCI designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 22
- Barry , D.T. , Gordon , K.E. & Hinton , G.G. ( 1990 ). Acoustic and surface EMG diagnosis of pediatric muscle disease. Muscle & ; Nerve , 13(4), 286--290. Barry, D.T., Gordon, K.E. & Hinton, G.G. (1990). Acoustic and surface EMG diagnosis of pediatric muscle disease. Muscle & Nerve, 13(4), 286--290.
- Basmajian , J.V. , & De Luca , C.J. ( 1985 ). Muscles alive: Their functions revealed by electromyography , 5 th edition. Williams & Wilkins : Fort Worth, Texas . Basmajian, J.V., & De Luca, C.J. (1985). Muscles alive: Their functions revealed by electromyography, 5th edition. Williams & Wilkins: Fort Worth, Texas.
- 10.1023/A:1009715923555 · DOI · Paper page
- 10.1145/1054972.1055039 · DOI
- 10.1145/1240624.1240747 · DOI
- 10.1023/B:JOCM.0000025279.27084.39 · doi:10.1023/b:jocm.0000025279.27084.39
- 10.1155/2006/741851 · doi:10.1155/2006/741851
- 10.1145/800182.810395 · doi:10.1145/800182.810395
- Jiang , M.W. , Wang , R.C. , Wang , J.Z. , & Jin , D.W. ( 2005 ). A method of recognizing finger motion using wavelet transform of surface EMG signal . Intl Conf. of the IEEE EMBS , 1 ( 7 ), 2672 -- 2674 . Jiang, M.W., Wang, R.C., Wang, J.Z., & Jin, D.W. (2005). A method of recognizing finger motion using wavelet transform of surface EMG signal. Intl Conf. of the IEEE EMBS, 1(7), 2672--2674.
- 10.1109/TFUZZ.2004.832525 · DOI · Paper page
- 10.1109/CCECE.2004.1345029 · doi:10.1109/ccece.2004.1345029
- 10.1145/1166253.1166268 · DOI · Paper page
- 10.1109/IEMBS.2003.1280776 · doi:10.1109/iembs.2003.1280776
- 10.1145/1124772.1124926 · DOI · Paper page
- 10.1002/0471678384 · DOI · Paper page
- 10.1177/036354659202000206 · DOI · Paper page
- Naik , G.R. , Kumar , D.K. , Singh , V.P. , & Palaniswami , M. ( 2006 ). Hand gestures for HCI using ICA of EMG . HCSNet Workshop on the Use of Vision in HCI, 67--72 . Naik, G.R., Kumar, D.K., Singh, V.P., & Palaniswami, M. (2006). Hand gestures for HCI using ICA of EMG. HCSNet Workshop on the Use of Vision in HCI, 67--72.
- 10.1109/TNSRE.2002.806831 · DOI
- 10.1251/bpo115 · DOI · Paper page
- 10.1523/JNEUROSCI.15-01-00284.1995 · DOI · Paper page
- 10.1109/MPRV.2003.1203754 · DOI
- Witten , I.H. , & Frank , E. ( 2005 ). Data mining: Practical machine learning tools and techniques , 2 nd Ed., Morgan Kaufmann : San Francisco . Witten, I.H., & Frank, E. (2005). Data mining: Practical machine learning tools and techniques, 2nd Ed., Morgan Kaufmann: San Francisco.
Cited by
Surface EMG-Based Inter-Session Gesture Recognition Enhanced by Deep Domain Adaptation
Du, Y., Jin, W., Wei, W., Hu, Y., & Geng, W. (2017) · Sensors · doi:10.3390/s17030458 · Cited by 363
Lu, Z., Chen, X., Li, Q., Zhang, X., & Zhou, P. (2014) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2014.2302794 · Cited by 294
Tomo: Wearable, Low-Cost Electrical Impedance Tomography for Hand Gesture Recognition
Zhang, Y., & Harrison, C. (2015) · Proceedings of the 28th Annual ACM Symposium on User Interface Software & Technology · doi:10.1145/2807442.2807480 · Cited by 283
Artificial Intelligence and Biosensors in Healthcare and Its Clinical Relevance: A Review
(2023) · doi:10.1109/access.2023.3285596 · Cited by 205
Hand Gesture Recognition Based Omnidirectional Wheelchair Control Using IMU and EMG Sensors
Kundu, A. S., Mazumder, O., Lenka, P. K., & Bhaumik, S. (2018) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-017-0725-0 · Cited by 152
Metadata
- Authors
- Saponas, T. S., Tan, D. S., Morris, D., & Balakrishnan, R.
- Venue
- Proceedings of the SIGCHI Conference on Human Factors in Computing Systems
- Publisher
- ACM
- Published
- 2008-04-06
- Pages
- 515-524
- OpenAlex
- W2152528000
- Cited by
- 275
- References
- 0
- FWCI
- 27.63
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces. https://app.cochat.ai/papers/10.1145/1357054.1357138
- The paper
- Saponas, T. S., Tan, D. S., Morris, D., & Balakrishnan, R. (2008). Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces. Proceedings of the SIGCHI Conference on Human Factors in Computing Systems. https://doi.org/10.1145/1357054.1357138
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.