Transfer function analysis of respiratory sinus arrhythmia: A measure of autonomic function in diabetic neuropathy
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Standard techniques measuring heart rate (HR) variability do not account for its dependence on the rate and depth of respiration or measure the time relationship between changes in lung volume and HR. We used transfer function analysis to determine the magnitude and time relationship of the HR response to a known change in lung volume in controls and diabetics. This technique demonstrated significant differences between controls and diabetics with varying degrees of autonomic dysfunction. Specifically, reduced supine vagal and increased supine sympathetic HR modulation was found with progression of the autonomic neuropathy. In response to postural change the normal diabetics displayed impaired sympathetic HR modulation. Transfer function analysis yields new insight into the sequence of changes that occur with diabetic autonomic neuropathy and provides an accurate, easily comprehensible measurement of respiratory induced HR variability.© 1995 John Wiley &Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876
Self-citationRespiratory sinus arrhythmia in humans: how breathing pattern modulates heart rate
Hirsch, J. A., & Bishop, B. (1981) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1981.241.4.h620 · Cited by 1,105
Human sinus arrhythmia as an index of vagal cardiac outflow.
Eckberg, D. L. (1983) · Journal of Applied Physiology · doi:10.1152/jappl.1983.54.4.961 · Cited by 633
Respiratory sinus arrhythmia: a frequency dependent phenomenon
Angelone, A., & Coulter, N. A. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.3.479 · Cited by 441 · cited 1×
“The pattern of transfer magnitude changes for the mild and severe diabetic groups is similar to the controls, but of much lower magnitude and for the most part accompanied by steeply negative phase slopes indicating that these groups: (1) have less parasympathetic modulation to withdraw; and (2) despite an attempt to…”
BackgroundSpectral analysis of heart rate variability in the assessment of autonomic diabetic neuropathy
Pagani, M., Malfatto, G., Pierini, S., Casati, R., Masu, A. M., Poli, M., Guzzetti, S., Lombardi, F., Cerutti, S., & Malliani, A. (1988) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(88)90078-1 · Cited by 378
Cited by
Vinik, A. I., Maser, R. E., Mitchell, B. D., & Freeman, R. (2003) · Diabetes Care · doi:10.2337/diacare.26.5.1553 · Cited by 2,044
Self-citationThe many metrics of cardiac chronotropy: A pragmatic primer and a brief comparison of metrics
Allen, J. J. B., Chambers, A. S., & Towers, D. N. (2007) · Biological Psychology · doi:10.1016/j.biopsycho.2006.08.005 · Cited by 491
“A variant of this method calculates the transfer magnitude (e.g., Freeman et al., 1995), which expresses the gain between heart rate (in beats per minute) per liter of lung volume, with a large gain indicating that relatively small changes in lung volume result in sizable changes in heart rate.”
MethodAssessment of cardiovascular autonomic function
Freeman, R. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.09.027 · Cited by 262
Self-citationRespiratory sinus arrhythmia, cardiac vagal control, and daily activity.
Grossman, P., Wilhelm, F. H., & Spoerle, M. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00825.2003 · Cited by 197
“Used in previous research (12, 15, 32, 45, 51, 53), this parameter is the transfer function, or gain, of RSA in milliseconds per milliliter of tidal volume change.”
Transfer Function Analysis of Cerebral Autoregulation Dynamics in Autonomic Failure Patients
Blaber, A. P., Bondar, R. L., Stein, F., Dunphy, P. T., Moradshahi, P., Kassam, M. S., & Freeman, R. (1997) · Stroke · doi:10.1161/01.str.28.9.1686 · Cited by 181
Self-citation
Metadata
- Authors
- Freeman, R., Cohen, R. J., & Saul, J. P.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 1995-01
- Volume
- 18
- Issue
- 1
- Pages
- 74-84
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W2009796166
- Cited by
- 38
- References
- 5
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transfer function analysis of respiratory sinus arrhythmia: A measure of autonomic function in diabetic neuropathy. https://app.cochat.ai/papers/10.1002/mus.880180111
- The paper
- Freeman, R., Cohen, R. J., & Saul, J. P. (1995). Transfer function analysis of respiratory sinus arrhythmia: A measure of autonomic function in diabetic neuropathy. Muscle & Nerve. https://doi.org/10.1002/mus.880180111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.