Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 267

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Pelvic floor muscle exercise for the treatment of female stress urinary incontinence: II. Validity of vaginal pressure measurements of pelvic floor muscle strength and the necessity of supplementary methods for control of correct contraction

Bø, Kari, Kvarstein, Bernt, Hagen, Rolf R., Larsen, Stig·1990·Neurourology and Urodynamics

Abstract

The present investigation comprises three methodological studies concerning vaginal pressure measurements of pelvic floor muscle (PFM) strength. Vaginal pressure was measured by a balloon (6.7 ± 1.7 cm) connected by a catheter to a pressure transducer. The balloon was placed with the middle of the balloon 3.5 cm inside the introitus vagina. In fourty‐seven women, mean age 44.9 years (24–64), observation of movement of the vaginal catheter during PFM contraction verified 7 inconclusive results from perineovaginal palpation and was the most valid way to distinguish between correct and incorrect PFM contraction. Vaginal pressure rise was obtained regardless of correct or incorrect PFM contraction, showing that vaginal pressure is not specific for PFM contraction. However, as the action of the PFM is elevation, a simultaneous inward movement of the vaginal catheter is present only during correct PFM contraction. Degree of influence of various muscle groups on vaginal pressure was investigated in 14 women using two different balloons, one having a silicone reinforcement of the tip. It was found that the median contraction value of muscles other than the PFM did not exceed contraction of PFM alone. No significant difference was observed using the two types of balloons. In three physical therapists EMG activity of the lower m. rectus abdominis was recorded during maximal PFM contractions. A rise in EMG activity always occurred during maximal contractions even if the women actively tried to relax the abdominal muscles. It is concluded that vaginal pressure measurement of PFM strength is valid with simultaneous observation of inward movement of the balloon catheter. Vaginal pressure rise due to simultaneous contraction of other muscles is probably not larger than pressure rise due to intended PFM contraction. Reinforced balloon tip will not change pressure recording, and rise in EMG activity of lower abdominal muscles seems unavoidable during maximal PFM contraction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nau.1930090504

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 267

Metadata

Authors
Bø, K., Kvarstein, B., Hagen, R. R., & Larsen, S.
Venue
Neurourology and Urodynamics
Publisher
Wiley
Published
1990-01
Volume
9
Issue
5
Pages
479-487
ISSN
  • 0733-2467 (ISSN-L)
  • 1520-6777
OpenAlex
W2077210857
Cited by
267
References
8
FWCI
2.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pelvic floor muscle exercise for the treatment of female stress urinary incontinence: II. Validity of vaginal pressure measurements of pelvic floor muscle strength and the necessity of supplementary methods for control of correct contraction. https://app.cochat.ai/papers/10.1002/nau.1930090504
The paper
Bø, K., Kvarstein, B., Hagen, R. R., & Larsen, S. (1990). Pelvic floor muscle exercise for the treatment of female stress urinary incontinence: II. Validity of vaginal pressure measurements of pelvic floor muscle strength and the necessity of supplementary methods for control of correct contraction. Neurourology and Urodynamics. https://doi.org/10.1002/nau.1930090504

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.