CoChat

The evaluation of pelvic floor muscle strength in women with pelvic floor dysfunction: A reliability and correlation study

Open access
Navarro Brazález, Beatriz, Torres Lacomba, María, de la Villa, Pedro, Sánchez Sánchez, Beatriz, Prieto Gómez, Virginia, Asúnsolo del Barco, Ángel, McLean, Linda · 2018 · Neurourology and Urodynamics
Cited by 126

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Aims: The purposes of this study were: (i) to evaluate the reliability of vaginal palpation, vaginal manometry, vaginal dynamometry; and surface (transperineal) electromyography (sEMG), when evaluating pelvic floor muscle (PFM) strength and/or activation; and (ii) to determine the associations among PFM strength measured using these assessments. Methods: One hundred and fifty women with pelvic floor disorders participated on one occasion, and 20 women returned for the same investigations by two different raters on 3 different days. At each session, PFM strength was assessed using palpation (both the modified Oxford Grading Scale and the Levator ani testing), manometry, and dynamometry; and PFM activation was assessed using sEMG. Results: The interrater reliability of manometry, dynamometry, and sEMG (both root‐mean‐square [RMS] and integral average) was high (Lin's Concordance Correlation Coefficient [CCC] = 0.95, 0.93, 0.91, 0.86, respectively), whereas the interrater reliability of both palpation grading scales was low (Cohen's Kappa [ k ] = 0.27‐0.38). The intrarater reliability of manometry (CCC = 0.96), and dynamometry (CCC = 0.96) were high, whereas intrarater reliability of both palpation scales ( k = 0.78 for both), and of sEMG (CCC = 0.79 vs 0.80 for RMS vs integral average) was moderate. The Bland‐Altman plot showed good inter and intrarater agreement, with little random variability for all instruments. The correlations among palpation, manometry, and dynamometry were moderate (coefficient of determination [ r 2 ] ranged from 0.52 to 0.75), however, transperineal sEMG amplitude was only weakly correlated with all measures of strength ( r 2 = 0.23‐0.30). Conclusions: Manometry and dynamometry are more reliable tools than vaginal palpation for the assessment of PFM strength in women with pelvic floor disorders, especially when different raters are involved. The different PFM strength measures used clinically are moderately correlated; whereas, PFM activation recorded using transperineal sEMG is only weakly correlated with PFM strength. Results from perineal sEMG should not be interpreted in the context of reporting PFM strength.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nau.23287

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 126

Metadata

Authors
Navarro Brazález, B., Torres Lacomba, M., de la Villa, P., Sánchez Sánchez, B., Prieto Gómez, V., Asúnsolo del Barco, Á., & McLean, L.
Venue
Neurourology and Urodynamics
Publisher
Wiley
Published
2017-04-28
Volume
37
Issue
1
Pages
269-277
ISSN
  • 0733-2467 (ISSN-L)
  • 1520-6777
OpenAlex
W2607868411
Cited by
126
References
3
FWCI
6.44
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.