Initial experience using a novel nerve stimulator for the management of pudendal neuralgia
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Aims: In patients with pudendal neuralgia, prior studies have shown efficacy in chronic stimulation with Interstim® (Medtronic, Inc.). This feasibility study reports on the initial experience of using a wireless system to power an implanted lead at the pudendal nerve, StimWave®, to treat pudendal neuralgia. Methods: Retrospective chart review identified patients with a lead placed at the pudendal nerve for neuralgia and powered wirelessly. Clinical outcomes were assessed at Postoperative visits and phone calls. Administered non‐validated follow‐up questionnaire evaluated the Global Response Assessment, percentage of pain improvement, satisfaction with device, and initial and current settings of the device (h/day of stimulation). Results: Thirteen patients had the StimWave® lead placed at the pudendal nerve, 12 (92%) female and 1 (7.6%) male. Mean age was 50 years (range: 20–58). Failed prior therapies include medical therapy (100%), pelvic floor physical therapy (92%), pudendal nerve blocks (85%), pelvic floor muscle trigger point injections (69%), neuromodulation (30.7%), or surgeries for urogenital pain (23.1%). After the trial period, 10/13 (76.9%) had >50% improvement in pain with 6/13 (46.1%) reporting 100% pain improvement. Nine underwent permanent lead placement. At last postoperative visit (range, 6–83 days), 5/9 patients reported >50% pain improvement. Seven patients reached for phone calls (22–759 days) reported symptoms to be “markedly improved” (n = 2), “moderately improved” (n = 4), or “slightly improved” (n = 1). At follow up, complications included lead migration (n = 2), broken wire (n = 1), or nonfunctioning antenna (n = 2). Conclusion: Complex patients with pudendal neuralgia may benefit from pudendal nerve stimulation via StimWave®.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“After the initial phase 10/13 (76.9%) reported a > 50% reduction in pain with 6/13 (46.1%) reporting complete pain relief; 9/10 chose to have long-term Stimwave therapyAt last post-operative visit, 5/9 (55.6%) reported continued benefit with long-term Stimwave. Two patients chose to have their device explanted at this stageSeven patients responded to phone call at 1 year, of which 100% reported”
From The Diagnosis and Management of Pudendal Neuralgia (2026) · cites this paper as [31]
In the citing paper
“At the initial phase, ten of the 13 patients reported a > 50% reduction in pain.”
From The Diagnosis and Management of Pudendal Neuralgia (2026) · cites this paper as [31]
In the citing paper
“Nine of these ten patients elected to have a permanent stimulator inserted post-initial phase of which seven of nine patients reported a maintained > 50% reduction in pain at the final follow-up.”
From The Diagnosis and Management of Pudendal Neuralgia (2026) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostic criteria for pudendal neuralgia by pudendal nerve entrapment (Nantes criteria)
Labat, J., Riant, T., Robert, R., Amarenco, G., Lefaucheur, J., & Rigaud, J. (2008) · Neurourology and Urodynamics · doi:10.1002/nau.20505 · Cited by 500
Robert, R., Labat, J.-J., Bensignor, M., Glemain, P., Deschamps, C., Raoul, S., & Hamel, O. (2005) · European Urology · doi:10.1016/j.eururo.2004.09.003 · Cited by 222
Research works printed but not linked: 14
- 10.1007/s00345-005-0502-8 · doi:10.1007/s00345-005-0502-8
- 10.1097/00006123-199708000-00015 · doi:10.1097/00006123-199708000-00015
- 10.1002/nau.20823 · DOI · Paper page
- Perryman LT, 2018, Spinal cord stimulation costs and complications can be reduced by wireless nanotechnology. A review of traditional equipment expenses compared to wireless stimulation, Am J Anesth Clin Res, 19
- 10.1097/01.spv.0000200406.08673.b8 · DOI
- 10.1007/s00384-011-1394-2 · DOI
- 10.1111/ner.12032 · DOI · Paper page
- 10.1111/j.1094-7159.2004.04018.x · doi:10.1111/j.1094-7159.2004.04018.x
- 10.1016/S0022-5347(05)67010-3 · DOI · Paper page
- 10.1016/j.juro.2011.04.059 · doi:10.1016/j.juro.2011.04.059
- 10.1016/j.ejpain.2008.01.014 · DOI · Paper page
- 10.1007/s10151-009-0554-7 · DOI
- 10.1002/nau.20118 · DOI · Paper page
- 10.1007/s00345-014-1304-7 · DOI
Cited by
The Diagnosis and Management of Pudendal Neuralgia
Ahmed, M., Zavridis, P., Hadjiconstanti, D., & Zis, P. (2026) · Pain and Therapy · doi:10.1007/s40122-025-00803-w · Cited by 7
Metadata
- Authors
- Hoang Roberts, L., Vollstedt, A., Volin, J., McCartney, T., & Peters, K. M.
- Venue
- Neurourology and Urodynamics
- Publisher
- Wiley
- Published
- 2021-06-30
- Volume
- 40
- Issue
- 6
- Pages
- 1670-1677
- ISSN
- 0733-2467
- 1520-6777
- Cited by
- 14
- References
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Initial experience using a novel nerve stimulator for the management of pudendal neuralgia. https://app.cochat.ai/papers/10.1002/nau.24735
- The paper
- Hoang Roberts, L., Vollstedt, A., Volin, J., McCartney, T., & Peters, K. M. (2021). Initial experience using a novel nerve stimulator for the management of pudendal neuralgia. Neurourology and Urodynamics. https://doi.org/10.1002/nau.24735
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.