The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Liver fibrosis: non‐invasive assessment with MR elastography
Open accessAbstract
The aim of this study was to assess the feasibility of using non‐invasive MR elastography for determining the stage of liver fibrosis. Twenty‐five consecutive patients who had liver biopsy for suspicion of chronic liver disease were included in the study. The stage of fibrosis on the biopsies was assessed according to the METAVIR scoring system from F0, no fibrosis, to F4, cirrhosis. MR elastography was performed by transmitting low‐frequency (65 Hz) mechanical waves into the liver with a transducer placed at the back of the patients. The MR pulse sequence was a motion‐sensitized spin‐echo sequence, phase‐locked to the mechanical excitation. The phase maps were processed to obtain shear elasticity and shear viscosity maps. The mean hepatic shear elasticity increased with increasing stage of fibrosis. The mean elasticity was 2.24 ± 0.23 kPa in the 11 patients without substantial fibrosis (F0–F1 grades), 2.56 ± 0.24 kPa in the four patients with substantial fibrosis (F2–F3) and 4.68 ± 1.61 kPa in the 10 patients with cirrhosis (F4). The differences between groups were statistically significant (p ≤ 0.05). The mean shear viscosity was significantly higher in the patients with cirrhosis (5.19 ± 1.85 Pa · s) than in the patients without cirrhosis (2.39 ± 0.86 Pa · s in F0–F1 and 2.27 ± 0.38 Pa · s in F2–F3 patients). It is concluded that non‐invasive MR elastography is a feasible method to assess the stage of liver fibrosis. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bataller, R., & Brenner, D. A. (2005) · Journal of Clinical Investigation · doi:10.1172/jci24282 · Cited by 4,958
Liver fibrosis – from bench to bedside
Friedman, S. L. (2003) · Journal of Hepatology · doi:10.1016/s0168-8278(02)00429-4 · Cited by 1,780
Cited by
Assessment of Hepatic Fibrosis With Magnetic Resonance Elastography
Yin, M., Talwalkar, J. A., Glaser, K. J., Manduca, A., Grimm, R. C., Rossman, P. J., Fidler, J. L., & Ehman, R. L. (2007) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2007.06.012 · Cited by 948
Xiao, G., Zhu, S., Xiao, X., Yan, L., Yang, J., & Wu, G. (2017) · Hepatology · doi:10.1002/hep.29302 · Cited by 895
Magnetic Resonance Elastography for the Noninvasive Staging of Liver Fibrosis
Huwart, L., Sempoux, C., Vicaut, E., Salameh, N., Annet, L., Danse, E., Peeters, F., ter Beek, L. C., Rahier, J., Sinkus, R., et al. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.03.076 · Cited by 731
Self-citationQuantifying Hepatic Shear Modulus In Vivo Using Acoustic Radiation Force
Palmeri, M. L., Wang, M. H., Dahl, J. J., Frinkley, K. D., & Nightingale, K. R. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.10.009 · Cited by 683
Magnetic resonance elastography of liver: Technique, analysis, and clinical applications
Venkatesh, S. K., Yin, M., & Ehman, R. L. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23731 · Cited by 659
Metadata
- Authors
- Huwart, L., Peeters, F., Sinkus, R., Annet, L., Salameh, N., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2006-03-06
- Volume
- 19
- Issue
- 2
- Pages
- 173-179
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2016706835
- Cited by
- 417
- References
- 2
- FWCI
- 21.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liver fibrosis: non‐invasive assessment with MR elastography. https://app.cochat.ai/papers/10.1002/nbm.1030
- The paper
- Huwart, L., Peeters, F., Sinkus, R., Annet, L., Salameh, N., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E. (2006). Liver fibrosis: non‐invasive assessment with MR elastography. NMR in Biomedicine. https://doi.org/10.1002/nbm.1030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.