The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Liver fibrosis: non‐invasive assessment with MR elastography
Open accessAbstract
The aim of this study was to assess the feasibility of using non‐invasive MR elastography for determining the stage of liver fibrosis. Twenty‐five consecutive patients who had liver biopsy for suspicion of chronic liver disease were included in the study. The stage of fibrosis on the biopsies was assessed according to the METAVIR scoring system from F0, no fibrosis, to F4, cirrhosis. MR elastography was performed by transmitting low‐frequency (65 Hz) mechanical waves into the liver with a transducer placed at the back of the patients. The MR pulse sequence was a motion‐sensitized spin‐echo sequence, phase‐locked to the mechanical excitation. The phase maps were processed to obtain shear elasticity and shear viscosity maps. The mean hepatic shear elasticity increased with increasing stage of fibrosis. The mean elasticity was 2.24 ± 0.23 kPa in the 11 patients without substantial fibrosis (F0–F1 grades), 2.56 ± 0.24 kPa in the four patients with substantial fibrosis (F2–F3) and 4.68 ± 1.61 kPa in the 10 patients with cirrhosis (F4). The differences between groups were statistically significant (p ≤ 0.05). The mean shear viscosity was significantly higher in the patients with cirrhosis (5.19 ± 1.85 Pa · s) than in the patients without cirrhosis (2.39 ± 0.86 Pa · s in F0–F1 and 2.27 ± 0.38 Pa · s in F2–F3 patients). It is concluded that non‐invasive MR elastography is a feasible method to assess the stage of liver fibrosis. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bataller, R., & Brenner, D. A. (2005) · Journal of Clinical Investigation · doi:10.1172/jci24282 · Cited by 4,958
An Algorithm for the Grading of Activity in Chronic Hepatitis C
Bedossa, P., & Poynard, T. (1996) · Hepatology · doi:10.1002/hep.510240201 · Cited by 4,088
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Castéra, L., Vergniol, J., Foucher, J., Le Bail, B., Chanteloup, E., Haaser, M., Darriet, M., Couzigou, P., & de Lédinghen, V. (2005) · Gastroenterology · doi:10.1053/j.gastro.2004.11.018 · Cited by 2,487
Sampling Variability of Liver Fibrosis in Chronic Hepatitis C
Bedossa, P., Dargère, D., & Paradis, V. (2003) · Hepatology · doi:10.1016/j.hep.2003.09.022 · Cited by 2,376
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection
Regev, A., Berho, M. E., Jeffers, L. J., Milikowski, C., Molina, E. G., Pyrsopoulos, N., Feng, Z.-Z., Reddy, K. R., & Schiff, E. R. (2002) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(02)04396-4 · Cited by 2,093
Bravo, A. A., Sheth, S. G., & Chopra, S. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102153440706 · Cited by 2,041
Bedossa, P. (1994) · Hepatology · doi:10.1002/hep.1840200104 · Cited by 2,003
Liver fibrosis – from bench to bedside
Friedman, S. L. (2003) · Journal of Hepatology · doi:10.1016/s0168-8278(02)00429-4 · Cited by 1,780
Cited by
Assessment of Hepatic Fibrosis With Magnetic Resonance Elastography
Yin, M., Talwalkar, J. A., Glaser, K. J., Manduca, A., Grimm, R. C., Rossman, P. J., Fidler, J. L., & Ehman, R. L. (2007) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2007.06.012 · Cited by 948
Xiao, G., Zhu, S., Xiao, X., Yan, L., Yang, J., & Wu, G. (2017) · Hepatology · doi:10.1002/hep.29302 · Cited by 895
Magnetic Resonance Elastography for the Noninvasive Staging of Liver Fibrosis
Huwart, L., Sempoux, C., Vicaut, E., Salameh, N., Annet, L., Danse, E., Peeters, F., ter Beek, L. C., Rahier, J., Sinkus, R., et al. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.03.076 · Cited by 731
Self-citationQuantifying Hepatic Shear Modulus In Vivo Using Acoustic Radiation Force
Palmeri, M. L., Wang, M. H., Dahl, J. J., Frinkley, K. D., & Nightingale, K. R. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.10.009 · Cited by 683
Magnetic resonance elastography of liver: Technique, analysis, and clinical applications
Venkatesh, S. K., Yin, M., & Ehman, R. L. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23731 · Cited by 659
Increased stiffness of the rat liver precedes matrix deposition: implications for fibrosis
Georges, P. C., Hui, J.-J., Gombos, Z., McCormick, M. E., Wang, A. Y., Uemura, M., Mick, R., Janmey, P. A., Furth, E. E., & Wells, R. G. (2007) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00032.2007 · Cited by 577
Singh, S., Venkatesh, S. K., Wang, Z., Miller, F. H., Motosugi, U., Low, R. N., Hassanein, T., Asbach, P., Godfrey, E. M., Yin, M., et al. (2015) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2014.09.046 · Cited by 547
Shearwave dispersion ultrasound vibrometry (SDUV) for measuring tissue elasticity and viscosity
Chen, S., Urban, M., Pislaru, C., Kinnick, R., Zheng, Y., Yao, A., & Greenleaf, J. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1005 · Cited by 522
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savery, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 510
Quantitative Assessment of Normal Soft-Tissue Elasticity Using Shear-Wave Ultrasound Elastography
Arda, K., Ciledag, N., Aktas, E., Arıbas, B. K., & Köse, K. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5449 · Cited by 467
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Muller, M., Gennisson, J.-L., Deffieux, T., Tanter, M., & Fink, M. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.08.018 · Cited by 400
Diagnosis and Quantitation of Fibrosis
Manning, D. S., & Afdhal, N. H. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.03.001 · Cited by 399
Huwart, L., Sempoux, C., Salameh, N., Jamart, J., Annet, L., Sinkus, R., Peeters, F., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E. (2007) · Radiology · doi:10.1148/radiol.2452061673 · Cited by 365
Self-citationMechanical properties of whole-body soft human tissues: a review
Singh, G., & Chanda, A. (2021) · Biomedical Materials · doi:10.1088/1748-605x/ac2b7a · Cited by 364
Palmeri, M. L., Wang, M. H., Rouze, N. C., Abdelmalek, M. F., Guy, C. D., Moser, B., Diehl, A. M., & Nightingale, K. R. (2011) · Journal of Hepatology · doi:10.1016/j.jhep.2010.12.019 · Cited by 344
Klatt, D., Hamhaber, U., Asbach, P., Braun, J., & Sack, I. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/24/006 · Cited by 333
The management of portal hypertension: Rational basis, available treatments and future options
Bosch, J., Berzigotti, A., Garcia-Pagan, J. C., & Abraldes, J. G. (2008) · Journal of Hepatology · doi:10.1016/j.jhep.2008.01.021 · Cited by 319
Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastography
Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., & Braun, J. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1189 · Cited by 316
Magnetic resonance imaging of hepatic fibrosis: Emerging clinical applications
Talwalkar, J. A., Yin, M., Fidler, J. L., Sanderson, S. O., Kamath, P. S., & Ehman, R. L. (2008) · Hepatology · doi:10.1002/hep.21972 · Cited by 314
MR Elastography of Liver Tumors: Preliminary Results
Venkatesh, S. K., Yin, M., Glockner, J. F., Takahashi, N., Araoz, P. A., Talwalkar, J. A., & Ehman, R. L. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3123 · Cited by 312
Hepatic MR Elastography: Clinical Performance in a Series of 1377 Consecutive Examinations
Yin, M., Glaser, K. J., Talwalkar, J. A., Chen, J., Manduca, A., & Ehman, R. L. (2016) · Radiology · doi:10.1148/radiol.2015142141 · Cited by 276
Diffusion-weighted magnetic resonance imaging for the assessment of fibrosis in chronic hepatitis C
Lewin, M., Poujol-Robert, A., Boëlle, P.-Y., Wendum, D., Lasnier, E., Viallon, M., Guéchot, J., Hoeffel, C., Arrivé, L., Tubiana, J.-M., et al. (2007) · Hepatology · doi:10.1002/hep.21747 · Cited by 265
Assessment of liver viscoelasticity using multifrequency MR elastography
Asbach, P., Klatt, D., Hamhaber, U., Braun, J., Somasundaram, R., Hamm, B., & Sack, I. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21636 · Cited by 264
Singh, S., Venkatesh, S. K., Loomba, R., Wang, Z., Sirlin, C., Chen, J., Yin, M., Miller, F. H., Low, R. N., Hassanein, T., et al. (2016) · European Radiology · doi:10.1007/s00330-015-3949-z · Cited by 252
Nonalcoholic fatty liver disease
Erickson, S. K. (2009) · Journal of Lipid Research · doi:10.1194/jlr.r800089-jlr200 · Cited by 194
General review of magnetic resonance elastography
Low, G. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i1.59 · Cited by 123
Osman, K. T., Maselli, D. B., Idilman, I. S., Rowan, D. J., Viehman, J. K., Harmsen, W. S., Harnois, D. M., Carey, E. J., Gossard, A. A., LaRusso, N. F., et al. (2021) · Journal of Clinical Gastroenterology · doi:10.1097/mcg.0000000000001433 · Cited by 64
Metadata
- Authors
- Huwart, L., Peeters, F., Sinkus, R., Annet, L., Salameh, N., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2006-03-06
- Volume
- 19
- Issue
- 2
- Pages
- 173-179
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2016706835
- Cited by
- 417
- References
- 32
- FWCI
- 21.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.