Effective medium theory of a diffusion‐weighted signal
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Living tissues and other heterogeneous media generally consist of structural units with different diffusion coefficients and NMR properties. These blocks, such as cells or clusters of cells, can be much smaller than the imaging voxel, and are often comparable with the diffusion length. We have developed a general approach to quantify the medium heterogeneity when it is much finer than the sample size or the imaging resolution. The approach is based on the treatment of the medium statistically in terms of the correlation functions of the local parameters. The diffusion‐weighted signal is explicity found for the case in which the local diffusivity varies in space, in the lowest order in the diffusivity variance. We demonstrate how the correlation length and the variance of the local diffusivity contribute to the time‐dependent diffusion coefficient and the time‐dependent kurtosis. Our results are corroborated by Monte Carlo simulations of diffusion in a two‐dimensional heterogeneous medium. Copyright © 2010 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anomalous diffusion in disordered media: Statistical mechanisms, models and physical applications
Bouchaud, J.-P., & Georges, A. (1990) · Physics Reports · doi:10.1016/0370-1573(90)90099-n · Cited by 4,162
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488 · cited 10×
“The Taylor expansion (eqn [15]), substituted in eqn [12], allows one to represent the disorder-averaged particle current Jðt; rÞ in terms of the gradients of the disorder-averaged particle density Cðt; rÞ, thereby generalizing Fick’s law (eqn [17]).”
BackgroundMethodInfluentialAxcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849 · cited 2×
“In this case, one either needs to sum up a number of successive terms in the perturbation series for S, which will involve higher order correlators (eqn [14]), and/or utilize”
BackgroundAssaf, Y., Freidlin, R. Z., Rohde, G. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20274 · Cited by 519
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501 · cited 1×
“Comparing expansions [22] and [23] term-by-term and using eqn [7], we find successive relations for the moments of the molecular displacements:”
MethodJespersen, S. N., Bjarkam, C. R., Nyengaard, J. R., Chakravarty, M. M., Hansen, B., Vosegaard, T., Østergaard, L., Yablonskiy, D., Nielsen, N. C., & Vestergaard-Poulsen, P. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.08.053 · Cited by 290
Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain
Does, M. D., Parsons, E. C., & Gore, J. C. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10385 · Cited by 246 · cited 4×
“The subsequent terms of this series can be determined via the convolutions of the free propagators (eqn [10]) with the correlation functions”
BackgroundInfluential
Cited by
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Self-citationQuantification of increased cellularity during inflammatory demyelination
Wang, Y., Wang, Q., Haldar, J. P., Yeh, F.-C., Xie, M., Sun, P., Tu, T.-W., Trinkaus, K., Klein, R. S., Cross, A. H., et al. (2011) · Brain · doi:10.1093/brain/awr307 · Cited by 384
“Diffusion-weighted MRI signals reflect an ensemble-averaged diffusion effect arising from various microscopic structures (Novikov and Kiselev, 2010).”
Novikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366
Self-citationRevealing mesoscopic structural universality with diffusion
Novikov, D. S., Jensen, J. H., Helpern, J. A., & Fieremans, E. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1316944111 · Cited by 348
Self-citationDesign and Validation of Diffusion MRI Models of White Matter
Jelescu, I. O., & Budde, M. D. (2017) · Frontiers in Physics · doi:10.3389/fphy.2017.00061 · Cited by 240
“Moreover, the estimated distribution does not mirror the actual distribution of diffusion coefficients in the tissue unless the measurement is performed in a very strong diffusion weighting regime (qlc ≫ 1, where q is the amount of spatial phase-warping introduced and lc is the diffusion distance) [9, 22].”
Metadata
- Authors
- Novikov, D. S., & Kiselev, V. G.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2010-08
- Volume
- 23
- Issue
- 7
- Pages
- 682-697
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2117927530
- Cited by
- 139
- References
- 7
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.