Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

2D and 3D high resolution gradient echo functional imaging of the brain: Venous contributions to signal in motor cortex studies

Haacke, E. M., Hopkins, A., Lai, S., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., Friedland, R., Klein, S., Thompson, L., Detterman, D., Tkach, J., Lewin, J. S.·1994·NMR in Biomedicine

Abstract

Recent emphasis on high resolution gradient echo studies in functional imaging has led to the conclusion that there are likely three domains of response to the blood circulation in the brain when considering field inhomogeneity effects of the venous blood pre‐ and during activation. The first is a coherent effect due to large or macroscopic vessels on the order of the size of the voxel (ca 200–500 μm in most studies). These can lead to very large signal changes (up to 100%). The second is at the venule level (ca 50–200 μm) and is associated with smaller parenchymal changes (usually ca 10% or less). The third is at the capillary level and is associated with much smaller signal changes at 1.5T and even up to 4 T. The actual signal changes depend on field strength and sequence design. In this paper, we present our experience in detecting the first two domains with 2D and 3D gradient echo imaging at 1.5T. We find that high resolution enables visualization of the larger small veins in motor cortex studies and that, on occasion, it is possible to see the venule effects as well. We suggest a simple model to explain the large signal changes based on susceptibility changes and partial volume effects. Comparisons of the functional imaging data to this model and to MR angiographic studies are also shown as evidence of the venous sources of the susceptibility changes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nbm.1940070109

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 167

Metadata

Authors
Haacke, E. M., Hopkins, A., Lai, S., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., Friedland, R., Klein, S., Thompson, L., Detterman, D., Tkach, J., & Lewin, J. S.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
1994-03
Volume
7
Issue
1-2
Pages
54-62
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W2081644951
Cited by
167
References
1
FWCI
15.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 2D and 3D high resolution gradient echo functional imaging of the brain: Venous contributions to signal in motor cortex studies. https://app.cochat.ai/papers/10.1002/nbm.1940070109
The paper
Haacke, E. M., Hopkins, A., Lai, S., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., Friedland, R., Klein, S., Thompson, L., Detterman, D., Tkach, J., & Lewin, J. S. (1994). 2D and 3D high resolution gradient echo functional imaging of the brain: Venous contributions to signal in motor cortex studies. NMR in Biomedicine. https://doi.org/10.1002/nbm.1940070109

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.