A theoretical and experimental comparison of different techniques for B1 mapping at very high fields
The DOI matches its Crossref record.
Abstract
With the increasing use of ultrahigh‐field MR with multiple transmit channels, mapping of the B1+ field has become a critical factor in many studies, leading to the publication of a large number of sequences for the measurement of the flip angle in recent years. In this article, the accuracy, precision and practicability of some of the most prominent of these techniques are investigated both theoretically, using error propagation computations and Monte‐Carlo simulations, and experimentally for different settings. For an exemplary experiment, which is typical for high‐field applications, the flip angle uncertainty is calculated and measured for two‐ and three‐dimensional acquisitions for techniques based on both magnitude and phase data. Simulated and measured results show good agreement. An experimental assessment of T1 and B0 dependence yields weak variations with these parameters for only a few of the sequences. Measurements on human scanners show crucial influences of specific absorption rate limitations, especially at ultrahigh field. Copyright © 2012 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L. J., Helms, G., Mohammadi, S., & Kirilina, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 300
On the accuracy of T1 mapping: Searching for common ground
Stikov, N., Boudreau, M., Levesque, I. R., Tardif, C. L., Barral, J. K., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25135 · Cited by 285
hMRI – A toolbox for quantitative MRI in neuroscience and clinical research
Tabelow, K., Balteau, E., Ashburner, J., Callaghan, M. F., Draganski, B., Helms, G., Kherif, F., Leutritz, T., Lutti, A., Phillips, C., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.01.029 · Cited by 256
Advanced MRI techniques to improve our understanding of experience-induced neuroplasticity
Tardif, C. L., Gauthier, C. J., Steele, C. J., Bazin, P.-L., Schäfer, A., Schaefer, A., Turner, R., & Villringer, A. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.047 · Cited by 127
Bane, O., Hectors, S. J., Wagner, M., Arlinghaus, L. L., Aryal, M. P., Cao, Y., Chenevert, T. L., Fennessy, F., Huang, W., Hylton, N. M., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26903 · Cited by 109
Metadata
- Authors
- Pohmann, R., & Scheffler, K.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2012-09-13
- Volume
- 26
- Issue
- 3
- Pages
- 265-275
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2161191203
- Cited by
- 90
- References
- 0
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A theoretical and experimental comparison of different techniques for B1 mapping at very high fields. https://app.cochat.ai/papers/10.1002/nbm.2844
- The paper
- Pohmann, R., & Scheffler, K. (2013). A theoretical and experimental comparison of different techniques for B1 mapping at very high fields. NMR in Biomedicine. https://doi.org/10.1002/nbm.2844
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.