The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Qualitative and quantitative ultrashort‐TE MRI of cortical bone
Open accessAbstract
Osteoporosis causes over 1.5 million fractures per year, costing about $15 billion annually in the USA. Current guidelines utilize bone mineral density (BMD) to assess fracture risk; however, BMD alone only accounts for 30–50% of fractures. The other two major components of bone, organic matrix and water, contribute significantly to bone mechanical properties, but cannot be assessed with conventional imaging techniques in spite of the fact that they make up about 57% of cortical bone by volume. Conventional clinical MRI usually detects signals from water in tissues without difficulty, but cannot detect the water bound to the organic matrix, or the free water in the microscopic pores of the Haversian and the lacunar‐canalicular system of cortical bone, because of their very short apparent transverse relaxation times (T2*). In recent years, a new class of sequences, ultrashort‐TE (UTE) sequences, with nominal TEs of less than 100 µs, which are much shorter than the TEs available with conventional sequences, have received increasing interest. These sequences can detect water signals from within cortical bone and provide an opportunity to study disease of this tissue in a new way. This review summarizes the recent developments in qualitative UTE imaging (techniques and contrast mechanisms to produce bone images with high contrast) and quantitative UTE imaging (techniques to quantify the MR properties, including T1, T2* and the magnetization transfer ratio, and tissue properties, including bone perfusion, as well as total, bound and free water content) of cortical bone in vitro and in vivo. The limitations of the current techniques for clinical applications and future directions are also discussed. Copyright © 2012 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Risk Factors for Hip Fracture in White Women
Cummings, S. R., Nevitt, M. C., Browner, W. S., Stone, K., Fox, K. M., Ensrud, K. E., Cauley, J., Black, D., & Vogt, T. M. (1995) · New England Journal of Medicine · doi:10.1056/nejm199503233321202 · Cited by 3,595
THE CHEMICAL DYNAMICS OF BONE MINERAL
NEUMAN, W. F., & NEUMAN, M. W. (1959) · The American Journal Of The Medical Sciences · doi:10.1097/00000441-195912000-00030 · Cited by 1,032
Cummings, S. R., Karpf, D. B., Harris, F., Genant, H. K., Ensrud, K., LaCroix, A. Z., & Black, D. M. (2002) · The American Journal of Medicine · doi:10.1016/s0002-9343(01)01124-x · Cited by 752
McCalden, R. W., McGeough, J. A., Barker, M. B., & Court-Brown, C. M. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199308000-00009 · Cited by 709
Stiffness of compact bone: Effects of porosity and density
Schaffler, M. B., & Burr, D. B. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90186-8 · Cited by 652
Cited by
UTE imaging in the musculoskeletal system
Chang, E. Y., Du, J., & Chung, C. B. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24713 · Cited by 276
Self-citationMRI assessment of bone structure and microarchitecture
Chang, G., Boone, S., Martel, D., Rajapakse, C. S., Hallyburton, R. S., Valko, M., Honig, S., & Regatte, R. R. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25647 · Cited by 151
Small animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Metadata
- Authors
- Du, J., & Bydder, G. M.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2012-12-28
- Volume
- 26
- Issue
- 5
- Pages
- 489-506
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W1498844808
- Cited by
- 159
- References
- 6
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.