The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Minimum Reporting Standards for in vivo Magnetic Resonance Spectroscopy (MRSinMRS): Experts' consensus recommendations
Open accessAbstract
The translation of MRS to clinical practice has been impeded by the lack of technical standardization. There are multiple methods of acquisition, post‐processing, and analysis whose details greatly impact the interpretation of the results. These details are often not fully reported, making it difficult to assess MRS studies on a standardized basis. This hampers the reviewing of manuscripts, limits the reproducibility of study results, and complicates meta‐analysis of the literature. In this paper a consensus group of MRS experts provides minimum guidelines for the reporting of MRS methods and results, including the standardized description of MRS hardware, data acquisition, analysis, and quality assessment. This consensus statement describes each of these requirements in detail and includes a checklist to assist authors and journal reviewers and to provide a practical way for journal editors to ensure that MRS studies are reported in full.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000100 · Cited by 28,164
Dermyshi, E., Wang, Y., Yan, C., Hong, W., Qiu, G., Gong, X., & Zhang, T. (2017) · Neonatology · doi:10.1159/000454668 · Cited by 24,451
von Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., Vandenbroucke, J. P., & Initiative, F. T. S. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040296 · Cited by 23,020
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.006 · Cited by 10,578
von Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., & Vandenbroucke, J. P. (2014) · International Journal of Surgery · doi:10.1016/j.ijsu.2014.07.013 · Cited by 9,909
Moher, D., Hopewell, S., Schulz, K. F., Montori, V., Gotzsche, P. C., Devereaux, P. J., Elbourne, D., Egger, M., & Altman, D. G. (2010) · BMJ · doi:10.1136/bmj.c869 · Cited by 8,883
STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · BMJ · doi:10.1136/bmj.h5527 · Cited by 3,660 · cited 1×
“The data exclusion criteria should specifically provide the thresholds for which data were excluded, whether they were based on SNR, linewidth, and/or other quality measures, and the specifics of this measure, as this can bias the overall analysis of the study data.(18) For example, “subjects were excluded if the SNR…”
BackgroundEstimation of metabolite concentrations from localized in vivo proton NMR spectra
Provencher, S. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300604 · Cited by 3,655
Moher, D., Hopewell, S., Schulz, K. F., Montori, V., Gøtzsche, P. C., Devereaux, P. J., Elbourne, D., Egger, M., & Altman, D. G. (2012) · International Journal of Surgery · doi:10.1016/j.ijsu.2011.10.001 · Cited by 2,345
A call for transparent reporting to optimize the predictive value of preclinical research
Landis, S. C., Amara, S. G., Asadullah, K., Austin, C. P., Blumenstein, R., Bradley, E. W., Crystal, R. G., Darnell, R. B., Ferrante, R. J., Fillit, H., et al. (2012) · Nature · doi:10.1038/nature11556 · Cited by 1,196
Kreis, R., Ernst, T., & Ross, B. D. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300405 · Cited by 681
Self-citationClinical Proton MR Spectroscopy in Central Nervous System Disorders
Öz, G., Alger, J. R., Barker, P. B., Bartha, R., Bizzi, A., Boesch, C., Bolan, P. J., Brindle, K. M., Cudalbu, C., Dinçer, A., et al. (2014) · Radiology · doi:10.1148/radiol.13130531 · Cited by 660
Self-citationQuantitation of magnetic resonance spectroscopy signals: the jMRUI software package
Stefan, D., Cesare, F. D., Andrasescu, A., Popa, E., Lazariev, A., Vescovo, E., Strbak, O., Williams, S., Starcuk, Z., Cabanas, M., et al. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/10/104035 · Cited by 514
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Self-citationSimpson, R., Devenyi, G. A., Jezzard, P., Hennessy, T. J., & Near, J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26091 · Cited by 368
Self-citationNear, J., Harris, A. D., Juchem, C., Kreis, R., Marjańska, M., Öz, G., Slotboom, J., Wilson, M., & Gasparovic, C. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4257 · Cited by 342
Self-citationWilson, M., Reynolds, G., Kauppinen, R. A., Arvanitis, T. N., & Peet, A. C. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22579 · Cited by 332
The trouble with quality filtering based on relative Cramér‐Rao lower bounds
Kreis, R. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25568 · Cited by 261
Self-citationMR Spectroscopy and Spectroscopic Imaging of the Brain
Zhu, H., & Barker, P. B. (2011) · Methods in Molecular Biology · doi:10.1007/978-1-61737-992-5_9 · Cited by 208
Öz, G., Deelchand, D. K., Wijnen, J. P., Mlynárik, V., Xin, L., Mekle, R., Noeske, R., Scheenen, T. W. J., Tkáč, I., & the Experts' Working Group on Advanced Single Voxel H MRS (2021) · NMR in Biomedicine · doi:10.1002/nbm.4236 · Cited by 189
Self-citation31P magnetic resonance spectroscopy in skeletal muscle: Experts' consensus recommendations
Meyerspeer, M., Boesch, C., Cameron, D., Dezortová, M., Forbes, S. C., Heerschap, A., Jeneson, J. A. L., Kan, H. E., Kent, J., Layec, G., et al. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4246 · Cited by 176
Self-citationAdvanced magnetic resonance spectroscopic neuroimaging: Experts' consensus recommendations
Maudsley, A. A., Andronesi, O. C., Barker, P. B., Bizzi, A., Bogner, W., Henning, A., Nelson, S. J., Posse, S., Shungu, D. C., & Soher, B. J. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4309 · Cited by 159
Self-citationPeek, A. L., Rebbeck, T. J., Puts, N. A. J., Watson, J., Aguila, M. E. R., & Leaver, A. M. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116532 · Cited by 158
Self-citationContribution of macromolecules to brain 1 H MR spectra: Experts' consensus recommendations
Cudalbu, C., Behar, K. L., Bhattacharyya, P. K., Bogner, W., Borbáth, T., de Graaf, R. A., Rolf Gruetter, A., Henning, A., Juchem, C., Kreis, R., et al. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4393 · Cited by 144
Self-citationAccelerated MR spectroscopic imaging—a review of current and emerging techniques
Bogner, W., Otazo, R., & Henning, A. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4314 · Cited by 142
Self-citationKreis, R., Boer, V. O., Choi, I., Cudalbu, C., de Graaf, R. A., Gasparovic, C., Heerschap, A., Krššák, M., Lanz, B., Maudsley, A. A., et al. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4347 · Cited by 136
Self-citationSpectral editing in 1H magnetic resonance spectroscopy: Experts' consensus recommendations
Choi, I., Andronesi, O. C., Barker, P. B., Bogner, W., Edden, R. A. E., Kaiser, L. G., Lee, P., Marjańska, M., Terpstra, M., & de Graaf, R. A. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4411 · Cited by 129
Self-citationB 0 shimming for in vivo magnetic resonance spectroscopy: Experts' consensus recommendations
Juchem, C., Cudalbu, C., de Graaf, R. A., Rolf Gruetter, A., Henning, A., Hetherington, H. P., & Boer, V. O. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4350 · Cited by 109
Self-citationProton magnetic resonance spectroscopy in skeletal muscle: Experts' consensus recommendations
Krššák, M., Lindeboom, L., Schrauwen‐Hinderling, V. B., Szczepaniak, L. S., Derave, W., Lundbom, J., Befroy, D. E., Schick, F., Machann, J., Kreis, R., et al. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4266 · Cited by 91
Self-citationTkáč, I., Deelchand, D. K., Dreher, W., Hetherington, H. P., Kreis, R., Kumaragamage, C., Považan, M., Spielman, D. M., Strasser, B., & de Graaf, R. A. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4459 · Cited by 81
Self-citationMotion correction methods for MRS: experts' consensus recommendations
Andronesi, O. C., Bhattacharyya, P. K., Bogner, W., Choi, I., Hess, A. T., Lee, P., Meintjes, E. M., Tisdall, M. D., Zaitsev, M., & van der Kouwe, A. J. W. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4364 · Cited by 73
Self-citationResponse of metabolites with coupled spins to the STEAM sequence
Thompson, R. B., & Allen, P. S. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1128 · Cited by 64
Brain Edema in Chronic Hepatic Encephalopathy
Cudalbu, C., & Taylor-Robinson, S. D. (2019) · Journal of Clinical and Experimental Hepatology · doi:10.1016/j.jceh.2019.02.003 · Cited by 58
Self-citationMagnetic resonance spectroscopy in the rodent brain: Experts' consensus recommendations
Lanz, B., Abaei, A., Braissant, O., Choi, I., Cudalbu, C., Henry, P., Rolf Gruetter, A., Kara, F., Kantarci, K., Lee, P., et al. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4325 · Cited by 36
Self-citation
Metadata
- Authors
- Lin, A., Andronesi, O., Bogner, W., Choi, I., Coello, E., Cudalbu, C., Juchem, C., Kemp, G. J., Kreis, R., Krššák, M., Lee, P., Maudsley, A. A., Meyerspeer, M., Mlynarik, V., Near, J., Öz, G., Peek, A. L., Puts, N. A., Ratai, E., Tkáč, I., Mullins, P. G., & Experts' Working Group on Reporting Standards for MR Spectroscopy
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2021-02-09
- Volume
- 34
- Issue
- 5
- Pages
- e4484-e4484
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W3128512883
- Cited by
- 334
- References
- 34
- FWCI
- 23.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.