The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A comparison of cell and tissue extraction techniques using high‐resolution 1H‐NMR spectroscopy
Abstract
Analysis of brain metabolites by a wide range of analytical techniques is typically achieved using biochemical extraction methodologies that require either two separate samples or two separate extraction steps to prepare both aqueous and organic metabolite fractions. However there are a number of brain pathologies in which both aqueous metabolite and lipid changes occur so that a simultaneous extraction of both fractions would be valuable. The methanol–chloroform (M/C) technique enables extraction of both aqueous metabolites and lipids simultaneously. It is already well established for lipid extraction of cells and tissue but its efficiency and reproducibility for extraction of aqueous metabolites is unknown. Therefore, we compared the aqueous metabolite yield and the reproducibility of the M/C method to the commonly used perchloric acid (PCA) method, using 1 H‐NMR spectroscopy of adult rat brain and purified rat astrocyte culture extracts. The results indicate that M/C is a superior technique for aqueous metabolite extraction from both brain tissue and cells when compared to the PCA method. The M/C extraction technique enables the simultaneous extraction of both lipids and aqueous metabolites from a single sample using small solvent‐volumes, making it well suited for NMR investigations of both tissues and cells. Copyright © 2002 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A RAPID METHOD OF TOTAL LIPID EXTRACTION AND PURIFICATION
Bligh, E. G., & Dyer, W. J. (1959) · Canadian Journal of Biochemistry and Physiology · doi:10.1139/o59-099 · Cited by 54,751
Cited by
Beckonert, O., Keun, H. C., Ebbels, T. M. D., Bundy, J., Holmes, E., Lindon, J. C., & Nicholson, J. K. (2007) · Nature Protocols · doi:10.1038/nprot.2007.376 · Cited by 2,109
Deficiency in glutamine but not glucose induces MYC-dependent apoptosis in human cells
Yuneva, M., Zamboni, N., Oefner, P., Sachidanandam, R., & Lazebnik, Y. (2007) · The Journal of Cell Biology · doi:10.1083/jcb.200703099 · Cited by 690
“Metabolites were extracted from adherent cells by a procedure adopted from Le Belle et al. (2002).”
MethodQuantitative metabolomics using NMR
Wishart, D. S. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.001 · Cited by 582
Nutritional Ketosis Alters Fuel Preference and Thereby Endurance Performance in Athletes
Cox, P. J., Kirk, T., Ashmore, T., Willerton, K., Evans, R., Smith, A., Murray, A. J., Stubbs, B., West, J., McLure, S. W., et al. (2016) · Cell Metabolism · doi:10.1016/j.cmet.2016.07.010 · Cited by 530
Global metabolite analysis of yeast: evaluation of sample preparation methods
Villas‐Bôas, S. G., Højer‐Pedersen, J., Åkesson, M., Smedsgaard, J., & Nielsen, J. (2005) · Yeast · doi:10.1002/yea.1308 · Cited by 400
Metadata
- Authors
- Belle, J. E. L., Harris, N. G., Williams, S. R., & Bhakoo, K. K.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2002-01-25
- Volume
- 15
- Issue
- 1
- Pages
- 37-44
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2145022634
- Cited by
- 292
- References
- 1
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of cell and tissue extraction techniques using high‐resolution 1H‐NMR spectroscopy. https://app.cochat.ai/papers/10.1002/nbm.740
- The paper
- Belle, J. E. L., Harris, N. G., Williams, S. R., & Bhakoo, K. K. (2002). A comparison of cell and tissue extraction techniques using high‐resolution 1H‐NMR spectroscopy. NMR in Biomedicine. https://doi.org/10.1002/nbm.740
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.