The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Issues of spectral quality in clinical 1H‐magnetic resonance spectroscopy and a gallery of artifacts
Abstract
In spite of the facts that magnetic resonance spectroscopy (MRS) is applied as clinical tool in non‐specialized institutions and that semi‐automatic acquisition and processing tools can be used to produce quantitative information from MRS exams without expert information, issues of spectral quality and quality assessment are neglected in the literature of MR spectroscopy. Even worse, there is no consensus among experts on concepts or detailed criteria of quality assessment for MR spectra. Furthermore, artifacts are not at all conspicuous in MRS and can easily be taken for true, interpretable features. This article aims to increase interest in issues of spectral quality and quality assessment, to start a larger debate on generally accepted criteria that spectra must fulfil to be clinically and scientifically acceptable, and to provide a sample gallery of artifacts, which can be used to raise awareness for potential pitfalls in MRS. Copyright © 2004 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of metabolite concentrations from localized in vivo proton NMR spectra
Provencher, S. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300604 · Cited by 3,655
Java-based graphical user interface for the MRUI quantitation package
Naressi, A., Couturier, C., Devos, J. M., Janssen, M., Mangeat, C., Beer, R. D., & Graveron-Demilly, D. (2001) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/bf02668096 · Cited by 1,003
Pauly, J., Le Roux, P., Nishimura, D., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.75611 · Cited by 800
Kreis, R., Ernst, T., & Ross, B. D. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300405 · Cited by 681
Self-citationMichaelis, T., Merboldt, K. D., Bruhn, H., Hänicke, W., & Frahm, J. (1993) · Radiology · doi:10.1148/radiology.187.1.8451417 · Cited by 556
The principle of reciprocity in signal strength calculations?A mathematical guide
Hoult, D. I. (2000) · Concepts in Magnetic Resonance · doi:10.1002/1099-0534(2000)12:4<173::aid-cmr1>3.0.co;2-q · Cited by 550
In Vivo NMR Spectroscopy: Principles and Techniques
de Graaf, R. A. (2019) · Medical Entomology and Zoology · Cited by 504
Absolute Quantitation of Water and Metabolites in the Human Brain. I. Compartments and Water
Ernst, T., Kreis, R., & Ross, B. D. (1993) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1993.1055 · Cited by 504
Self-citationA new leukoencephalopathy with vanishing white matter
van der Knaap, M. S., Barth, P. G., Gabreëls, F. J. M., Franzoni, E., Begeer, J. H., Stroink, H., Rotteveel, J. J., & Valk, J. (1997) · Neurology · doi:10.1212/wnl.48.4.845 · Cited by 392
Cramér–Rao bounds: an evaluation tool for quantitation
Cavassila, S., Deval, S., Huegen, C., van Ormondt, D., & Graveron‐Demilly, D. (2001) · NMR in Biomedicine · doi:10.1002/nbm.701 · Cited by 331
Cited by
Image Quality Metrics: PSNR vs. SSIM
Hore, A., & Ziou, D. (2010) · 2010 20th International Conference on Pattern Recognition · doi:10.1109/icpr.2010.579 · Cited by 4,943
Magnetic Resonance Imaging: Principles and Techniques: Lessons for Clinicians
Grover, V. P. B., Tognarelli, J. M., Crossey, M. M. E., Cox, I. J., Taylor-Robinson, S. D., & McPhail, M. J. W. (2015) · Journal of Clinical and Experimental Hepatology · doi:10.1016/j.jceh.2015.08.001 · Cited by 510
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Self-citation1H MR Spectroscopy of the Brain: Absolute Quantification of Metabolites
Jansen, J. F. A., Backes, W. H., Nicolay, K., & Kooi, M. E. (2006) · Radiology · doi:10.1148/radiol.2402050314 · Cited by 405
Advances in neuro-oncology imaging
Langen, K.-J., Galldiks, N., Hattingen, E., & Shah, N. J. (2017) · Nature Reviews Neurology · doi:10.1038/nrneurol.2017.44 · Cited by 339
Metadata
- Authors
- Kreis, R.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2004-09-22
- Volume
- 17
- Issue
- 6
- Pages
- 361-381
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W1970674424
- Cited by
- 430
- References
- 44
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Issues of spectral quality in clinical 1H‐magnetic resonance spectroscopy and a gallery of artifacts. https://app.cochat.ai/papers/10.1002/nbm.891
- The paper
- Kreis, R. (2004). Issues of spectral quality in clinical 1H‐magnetic resonance spectroscopy and a gallery of artifacts. NMR in Biomedicine. https://doi.org/10.1002/nbm.891
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.