The DOI matches its Crossref record.
Voltage clamping with a single microelectrode
Abstract
A technique is described which allows neurons to be voltage clamped with a single microelectrode, and the advantages of this circuit with respect to conventional bridge techniques are discussed. In this circuit, the single micro electrode is rapidly switched from a current passing to a recording mode. The circuitry consists of: (1) an electronic switch; (2) a high impedance, ultralow input capacity amplifier; (3) a sample‐and‐hold module; (4) conventional voltage clamping circuitry. The closed electronic switch allows current to flow through the electrode. The switch then opens, and the electrode is in a recording mode. The low input capacity of the preamplifier allows the artifact from the current pulse to rapidly abate, after which time the circuit samples the membrane potential. This cycle is repeated at rates up to 10 kHz. The voltage clamping amplifier senses the output of the sample‐and‐hold module and adjusts the current pulse amplitude to maintain the desired membrane potential. The system was evaluated in Aplysia neurons by inserting two microelectrodes into a cell. One electrode was used to clamp the cell and the other to independently monitor membrane potential at a remote location in the soma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Voltage-clamp analysis of muscarinic excitation in hippocampal neurons
Halliwell, J. V., & Adams, P. R. (1982) · Brain Research · doi:10.1016/0006-8993(82)90954-4 · Cited by 1,041
Emerging issues of connexin channels: biophysics fills the gap
L. Harris, A. (2001) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583501003705 · Cited by 800
A model of the nerve impulse using two first-order differential equations
Hindmarsh, J. L., & Rose, R. M. (1982) · Nature · doi:10.1038/296162a0 · Cited by 778
Chapter 12 Potassium currents in hippocampal pyramidal cells
Storm, J. F. (1990) · Progress in Brain Research · doi:10.1016/s0079-6123(08)61248-0 · Cited by 743
Membrane properties of rat locus coeruleus neurones
Williams, J. T., North, R. A., Shefner, S. A., Nishi, S., & Egan, T. M. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90265-3 · Cited by 341
Metadata
- Authors
- Wilson, W. A., & Goldner, M. M.
- Venue
- Journal of Neurobiology
- Publisher
- Wiley
- Published
- 1975-07
- Volume
- 6
- Issue
- 4
- Pages
- 411-422
- ISSN
- 0022-3034 (ISSN-L)
- 1097-4695
- OpenAlex
- W1997277702
- Cited by
- 238
- References
- 0
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Voltage clamping with a single microelectrode. https://app.cochat.ai/papers/10.1002/neu.480060406
- The paper
- Wilson, W. A., & Goldner, M. M. (1975). Voltage clamping with a single microelectrode. Journal of Neurobiology. https://doi.org/10.1002/neu.480060406
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.