Development and Validation of an Automated Sepsis Risk Assessment System
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Aggressive resuscitation can decrease sepsis mortality, but its success depends on early detection of sepsis. The purpose of this study was to develop and verify an Automated Sepsis Risk Assessment System (Auto‐SepRAS), which would automatically assess the sepsis risk of inpatients by applying data mining techniques to electronic health records (EHR) data and provide daily updates. The seven predictors included in the Auto‐SepRAS after initial analysis were admission via the emergency department, which had the highest odds ratio; diastolic blood pressure; length of stay; respiratory rate; heart rate; and age. Auto‐SepRAS classifies inpatients into three risk levels (high, moderate, and low) based on the predictive values from the sepsis risk‐scoring algorithm. The sepsis risk for each patient is presented on the nursing screen of the EHR. The AutoSepRAS was implemented retrospectively in several stages using EHR data and its cut‐off scores adjusted. Overall discrimination power was moderate (AUC>.80). The Auto‐SepRAS should be verified or updated continuously or intermittently to maintain high predictive performance, but it does not require invasive tests or data input by nurses that would require additional time. Nurses are able to provide patients with nursing care appropriate to their risk levels by using the sepsis risk information provided by the Auto‐SepRAS. In particular, with early detection of changes related to sepsis, nurses should be able to help in providing rapid initial resuscitation of high‐risk patients. © 2016 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Greiner, M., Pfeiffer, D., & Smith, R. D. (2000) · Preventive Veterinary Medicine · doi:10.1016/s0167-5877(00)00115-x · Cited by 1,923
The effect of age on the development and outcome of adult sepsis*
Martin, G. S., Mannino, D. M., & Moss, M. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000194535.82812.ba · Cited by 1,040
Solomon, R. S., Corwin, G. S., Barclay, D. C., Quddusi, S. F., & Dannenberg, M. D. (2016) · Journal of Hospital Medicine · doi:10.1002/jhm.2554 · Cited by 225
Implementation of a real-time computerized sepsis alert in nonintensive care unit patients*
Sawyer, A. M., Deal, E. N., Labelle, A. J., Witt, C., Thiel, S. W., Heard, K., Reichley, R. M., Micek, S. T., & Kollef, M. H. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e318205df85 · Cited by 169
Prospective Trial of Real-Time Electronic Surveillance to Expedite Early Care of Severe Sepsis
Nelson, J. L., Smith, B. L., Jared, J. D., & Younger, J. G. (2011) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.12.008 · Cited by 122
Hooper, M. H., Weavind, L., Wheeler, A. P., Martin, J. B., Gowda, S. S., Semler, M. W., Hayes, R. M., Albert, D. W., Deane, N. B., Nian, H., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e318250a887 · Cited by 121
Automated electronic medical record sepsis detection in the emergency department
Nguyen, S. Q., Mwakalindile, E., Booth, J. S., Hogan, V., Morgan, J., Prickett, C. T., Donnelly, J. P., & Wang, H. E. (2014) · PeerJ · doi:10.7717/peerj.343 · Cited by 68
Alsolamy, S., Al Salamah, M., Al Thagafi, M., Al-Dorzi, H. M., Marini, A. M., Aljerian, N., Al-Enezi, F., Al-Hunaidi, F., Mahmoud, A. M., Alamry, A., et al. (2014) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-014-0105-7 · Cited by 52
Cited by
Artificial Intelligence -based technologies in nursing: A scoping literature review of the evidence
von Gerich, H., Moen, H., Block, L. J., Chu, C. H., DeForest, H., Hobensack, M., Michalowski, M., Mitchell, J., Nibber, R., Olalia, M. A., et al. (2022) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2021.104153 · Cited by 360
“…, Zamzmi et al., 2019 54.8 ( Continued on next page ) Inferential statistics Ajay et al., 2016 , Aldaz et al., 2015 , Annapragada et al., 2021 , Back et al., 2016 , Barrera et al., 2020 , Bian et al., 2020 , Chun et al., 2021 , Cooper et al., 2021 , Cramer et al., 2019 , Devos et al., 2019 ,…”
InfluentialThe role of artificial intelligence in enhancing clinical nursing care: A scoping review
Ng, Z. Q. P., Ling, L. Y. J., Chew, H. S. J., & Lau, Y. (2022) · Journal of Nursing Management · doi:10.1111/jonm.13425 · Cited by 184
Hassan, N., Slight, R., Weiand, D., Vellinga, A., Morgan, G., Aboushareb, F., & Slight, S. P. (2021) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2021.104457 · Cited by 42
Enhancing sepsis management through machine learning techniques: A review
Ocampo-Quintero, N., Vidal-Cortés, P., del Río Carbajo, L., Fdez-Riverola, F., Reboiro-Jato, M., & Glez-Peña, D. (2022) · Medicina Intensiva · doi:10.1016/j.medin.2020.04.003 · Cited by 20
Metadata
- Authors
- Back, J., Jin, Y., Jin, T., & Lee, S.
- Venue
- Research in Nursing & Health
- Publisher
- Wiley
- Published
- 2016-06-21
- Volume
- 39
- Issue
- 5
- Pages
- 317-327
- ISSN
- 0160-6891 (ISSN-L)
- 1098-240X
- OpenAlex
- W2467949115
- Cited by
- 21
- References
- 8
- FWCI
- 0.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.