The ‘infinity cell’: A new trapped‐ion cell with radiofrequency covered trapping electrodes for fourier transform ion cyclotron resonance mass spectrometry
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The excitation event in Fourier transform ion cyclotron resonance mass spectrometry is optimized in order to obtain more reliable relative signal intensities and enhance the ion‐selection performance in multi‐tandem mass spectrometric experiments. Standard trapped‐ion cells suffer from the undesirable ejection of ions along the symmetry axis (z‐axis) of the cell, which is oriented parallel to the magnetic field lines. This z‐eiection effect is difficult to predict, and thus difficult to avoid, especially when complicated broad‐band excitation schemes are applied to the ions. An improved trapped‐ion cell design, referred to as the ‘Infinity Cell’, is discussed which eliminates z‐ejection. The Infinity Cell concept is based on the finding that it is possible to model the electric excitation field of an infinitely long cell with a cell of finite dimensions. The virtual elimination of z‐ejection effects is demonstrated in several suitable experiments by comparing the operation of the standard cell and the Infinity Cell.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fourier transform ion cyclotron resonance spectroscopy
Comisarow, M. B., & Marshall, A. G. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)89137-2 · Cited by 1,038
Tailored excitation for Fourier transform ion cyclotron mass spectrometry
Marshall, A. G., Wang, T. C. L., & Ricca, T. L. (1985) · Journal of the American Chemical Society · doi:10.1021/ja00312a015 · Cited by 631
The Measurement of eM by Cyclotron Resonance
Sommer, H., Thomas, H. A., & Hipple, J. A. (1951) · Physical Review · doi:10.1103/physrev.82.697 · Cited by 338
A Trapped Ion Analyzer Cell for Ion Cyclotron Resonance Spectroscopy
McIver, R. T. (1970) · Review of Scientific Instruments · doi:10.1063/1.1684576 · Cited by 172
Field-corrected ion cell for ion cyclotron resonance
Hanson, C. D., Castro, M. E., Kerley, E. L., & Russell, D. H. (1990) · Analytical Chemistry · doi:10.1021/ac00204a018 · Cited by 63
A new fourier-transform mass spectrometer with a superconducting magnet
Allemann, M., Kellerhals, H., & Wanczek, K. P. (1980) · Chemical Physics Letters · doi:10.1016/0009-2614(80)80525-2 · Cited by 58
Self-citation
Cited by
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
High-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
Milestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
Hendrickson, C. L., Quinn, J. P., Kaiser, N. K., Smith, D. F., Blakney, G. T., Chen, T., Marshall, A. G., Weisbrod, C. R., & Beu, S. C. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1182-2 · Cited by 278
Fourier Transform Mass Spectrometry
Scigelova, M., Hornshaw, M., Giannakopulos, A., & Makarov, A. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.009431 · Cited by 224
“been proposed to deal with the axial trapping field (21, 22).”
Background
Metadata
- Authors
- Caravatti, P., & Allemann, M.
- Venue
- Organic Mass Spectrometry
- Publisher
- Wiley
- Published
- 1991-05
- Volume
- 26
- Issue
- 5
- Pages
- 514-518
- ISSN
- 0030-493X (ISSN-L)
- OpenAlex
- W2069031182
- Cited by
- 385
- References
- 6
- FWCI
- 6.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.