The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Fourier Transform Mass Spectrometry
Open accessAbstract
This article provides an introduction to Fourier transform-based mass spectrometry. The key performance characteristics of Fourier transform-based mass spectrometry, mass accuracy and resolution, are presented in the view of how they impact the interpretation of measurements in proteomic applications. The theory and principles of operation of two types of mass analyzer, Fourier transform ion cyclotron resonance and Orbitrap, are described. Major benefits as well as limitations of Fourier transform-based mass spectrometry technology are discussed in the context of practical sample analysis, and illustrated with examples included as figures in this text and in the accompanying slide set. Comparisons highlighting the performance differences between the two mass analyzers are made where deemed useful in assisting the user with choosing the most appropriate technology for an application. Recent developments of these high-performing mass spectrometers are mentioned to provide a future outlook.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855
Kind, T., & Fiehn, O. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-105 · Cited by 1,201
Precision proteomics: The case for high resolution and high mass accuracy
Mann, M., & Kelleher, N. L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800788105 · Cited by 450
Research works printed but not linked: 61
- Kind, 2006, Metabolomic database annotations via query of elemental compositions: Mass accuracy is insufficient even at less than 1 ppm, Bioinformatics, 7, 234
- Böcker, 2009, SIRIUS: decomposing isotope patterns for metabolite identification, Bioinformatics, 25, 218, 10.1093/bioinformatics/btn603 · DOI · Paper page
- Zhu, 2007, Detection and structural characterization of glutathione-trapped reactive metabolites using liquid chromatography-high-resolution mass spectrometry and mass defect filtering, Anal. Chem, 79, 8333, 10.1021/ac071119u · doi:10.1021/ac071119u
- Cox, 2009, Computational principles of determining and improving mass precision and accuracy for proteome measurements in an orbitrap, J. Am. Soc. Mass Spectrom, 20, 1477, 10.1016/j.jasms.2009.05.007 · DOI
- Scheltema, 2008, Increasing the mass accuracy of high-resolution LC-MS data using background ions – a case study on the LTQ-Orbitrap, Proteomics, 8, 4647, 10.1002/pmic.200800314 · DOI
- Wobschall, 1965, Ion cyclotron resonance spectrometer, Rev. Sci. Instrum, 36, 466, 10.1063/1.1719601 · DOI
- Comisarow, 1974, Fourier transform ion cyclotron resonance spectroscopy, Chem. Phys. Lett, 25, 282, 10.1016/0009-2614(74)89137-2 · DOI · Paper page
- Rempel, 1986, Relation of signal sensitivity and ion z-motion in cubic cells. Theory and implication for ion kinetic studies, Int. J. Mass Spectrom. Ion Proc, 70, 163, 10.1016/0168-1176(86)80047-7 · DOI
- Kofel, 1986, Coupling of axial and radial motions in ICR cells during excitation, Int. J. Mass Spectrom. Ion Proc, 74, 1, 10.1016/0168-1176(86)85019-4 · doi:10.1016/0168-1176(86)85019-4
- Marshall, 1998, Fourier transform ion cyclotron resonance mass spectrometry: a primer, Mass Spectrom. Rev, 17, 1, 10.1002/(SICI)1098-2787(1998)17:1<1::AID-MAS1>3.0.CO;2-K · DOI · Paper page
- Comisarow, 1974, Frequency-sweep Fourier transform ion cyclotron resonance spectroscopy, Chem. Phys. Lett, 26, 489, 10.1016/0009-2614(74)80397-0 · DOI · Paper page
- Marshall, 1980, Theory of Fourier transform ion cyclotron resonance mass spectroscopy: Response to frequency-sweep excitation, J. Chem. Phys, 73, 1581, 10.1063/1.440338 · DOI · Paper page
- Guan, 1996, Stored waveform inverse Fourier transform (SWIFT) ion excitation in trapped-ion mass spectrometry: Theory and applications, Int. J. Mass Spectrom. Ion Proc, 157–158, 5, 10.1016/S0168-1176(96)04461-8 · DOI · Paper page
- O'Connor, 1995, High-resolution ion isolation with the ion cyclotron resonance capacitively coupled open cell, J. Am. Soc. Mass Spectrom, 6, 533, 10.1016/1044-0305(95)00232-3 · DOI
- Guan, 2010, High mass selectivity for top-down proteomics by application of SWIFT technology, J. Am. Soc. Mass Spectrom, 21, 455, 10.1016/j.jasms.2009.11.011 · DOI
- Ledford, 1984, Space-charge effects in Fourier-transform mass-spectrometry - mass calibration, Anal. Chem, 56, 2744, 10.1021/ac00278a027 · DOI · Paper page
- Wang, 1988, Mass shifts induced by negative frequency peaks in linearly polarized Fourier transform ion cyclotron resonance signals, Int. J. Mass Spectrom. Ion Proc, 86, 31, 10.1016/0168-1176(88)80053-3 · doi:10.1016/0168-1176(88)80053-3
- Syka, 2004, Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications, J. Proteome Res, 3, 621, 10.1021/pr0499794 · DOI · Paper page
- Hanson, 1990, Field-corrected ion cell for ion cyclotron resonance, Anal. Chem, 62, 520, 10.1021/ac00204a018 · DOI
- Caravatti, 1991, The infinity cell: a new trapped-ion cell with radiofrequency covered trapping electrodes for Fourier transform ion cyclotron resonance mass spectrometry, Org. Mass Spectrom, 26, 514, 10.1002/oms.1210260527 · DOI · Paper page
- Wang, 1989, A ”screened“ electrostatic ion trap for enhanced mass resolution, mass accuracy, reproducibility, and upper mass limit in Fourier-transform ion cyclotron resonance mass spectrometry, Anal. Chem, 61, 1288, 10.1021/ac00186a021 · doi:10.1021/ac00186a021
- Wang, 1990, Elimination of z-ejection in Fourier transform ion cyclotron resonance mass spectrometry by radio frequency electric field shimming, Anal. Chem, 62, 515, 10.1021/ac00204a017 · doi:10.1021/ac00204a017
- Beu, 1992, Elimination of axial ejection during excitation with a capacitively coupled open trapped-ion cell for Fourier transform ion cyclotron resonance mass spectrometry, Anal. Chem, 64, 177, 10.1021/ac00026a016 · DOI
- Bruce, 2000, A novel high-performance Fourier transform ion cyclotron resonance cell for improved biopolymer characterization, J. Mass Spectrom, 35, 85, 10.1002/(SICI)1096-9888(200001)35:1<85::AID-JMS910>3.0.CO;2-7 · DOI
- Marshall, 1979, Theoretical signal-to-noise ratio and mass resolution in Fourier transform ion cyclotron resonance mass spectrometry, Anal. Chem, 51, 1710, 10.1021/ac50047a029 · doi:10.1021/ac50047a029
- Marshall, 1979, Relaxation and spectral line shape in Fourier transform ion resonance spectroscopy, J. Chem. Phys, 71, 4434, 10.1063/1.438196 · DOI · Paper page
- Marshall, 1996, Advantages of high magnetic field for Fourier transform ion cyclotron mass spectrometry, Rapid Commun. Mass Spectrom, 10, 1819, 10.1002/(SICI)1097-0231(199611)10:14<1819::AID-RCM686>3.0.CO;2-Z · doi:10.1002/(sici)1097-0231(199611)10:14<1819::aid-rcm686>3.0.co;2-z
- Nikolaev, 2007, Realistic modeling of ion cloud motion in a Fourier transform ion cyclotron resonance cell by use of a particle-in-cell approach, Rapid Commun. Mass Spectrom, 21, 3527, 10.1002/rcm.3234 · DOI
- Lee, 1993, Multiple excitation collisional activation in fourier-transform mass spectrometry, Rapid Commun. Mass Spectrom, 7, 819, 10.1002/rcm.1290070908 · doi:10.1002/rcm.1290070908
- Boering, 1992, Control of ion kinetic energy in ion cyclotron resonance spectrometry: Very-low-energy collision-induced dissociation, Rapid Commun. Mass Spectrom, 6, 303, 10.1002/rcm.1290060416 · doi:10.1002/rcm.1290060416
- Gauthier, 1991, Sustained off-resonance irradiation for collision-activated dissociation involving Fourier transform mass spectrometry. Collision-activated dissociation technique that emulates infrared multiphoton dissociation, Anal. Chim. Acta, 246, 211, 10.1016/S0003-2670(00)80678-9 · DOI · Paper page
- Woodin, 1978, Multiphoton dissociation of molecules with low power continuous wave infrared laser radiation, J. Am. Chem. Soc, 100, 3248, 10.1021/ja00478a065 · DOI
- Peiris, 1993, Infrared multiple photon dissociation spectra of gaseous ions, J. Phys. Chem, 97, 7839, 10.1021/j100132a009 · doi:10.1021/j100132a009
- Williams, 1990, Efficiency of Collisionally-activated dissociation and 193-nm photodissociation of peptide ions in fourier transform mass spectrometry, J. Am. Soc. Mass Spectrom, 1, 288, 10.1016/1044-0305(90)85003-5 · DOI
- Little, 1994, Infrared multiphoton dissociation of large multiply charged ions for biomolecule sequencing, Anal. Chem, 66, 2809, 10.1021/ac00090a004 · DOI · Paper page
- Zubarev, 1998, Electron capture dissociation of multiply charged protein cations. A nonergodic process, J. Am. Chem. Soc, 120, 3265, 10.1021/ja973478k · DOI · Paper page
- Stensballe, 2000, Electron capture dissociation of singly and multiply phosphorylated peptides, Rapid Commun. Mass Spectrom, 14, 1793, 10.1002/1097-0231(20001015)14:19<1793::AID-RCM95>3.0.CO;2-Q · DOI · Paper page
- Shi, 2001, Phosphopeptide/ phosphoprotein mapping by electron capture dissociation mass spectrometry, Anal. Chem, 73, 19, 10.1021/ac000703z · DOI · Paper page
- Mirgorodskaya, 1999, Localization of O-glycosylation sites in peptides by electron capture dissociation in a Fourier transform mass spectrometer, Anal. Chem, 71, 4431, 10.1021/ac990578v · DOI · Paper page
- Kelleher, 1999, Localization of labile posttranslational modifications by electron capture dissociation: the case of gamma-carboxyglutamic acid, Anal. Chem, 71, 4250, 10.1021/ac990684x · DOI · Paper page
- Budnik, 2004, De novo sequencing of antimicrobial peptides isolated from the venom glands of the wolf spider, Lycosa singoriensis. J. Mass Spectrom, 39, 193, 10.1002/jms.577 · doi:10.1002/jms.577
- Kjeldsen, 2003, Complete characterization of posttranslational modification sites in the bovine milk protein PP3 by tandem mass spectrometry with electron capture dissociation as the last stage, Anal. Chem, 75, 2355, 10.1021/ac026295b · doi:10.1021/ac026295b
- Kjeldsen, 2002, Dissociative capture of hot (3–13 eV) electrons by polypeptide polycations: an efficient process accompanied by secondary fragmentation, Chem. Phys. Lett, 356, 201, 10.1016/S0009-2614(02)00149-5 · doi:10.1016/s0009-2614(02)00149-5
- Adams, 2005, Distinguishing and quantifying peptides and proteins containing D-amino acids by tandem mass spectrometry, Anal. Chem, 77, 4571, 10.1021/ac0503963 · DOI
- Ge, 2002, Top down characterization of larger proteins (45 kDa) by electron capture dissociation mass spectrometry, J. Am. Chem. Soc, 124, 672, 10.1021/ja011335z · DOI · Paper page
- Han, 2008, Mass spectrometry for proteomics, Curr. Opin. Chem. Biol, 12, 483, 10.1016/j.cbpa.2008.07.024 · DOI · Paper page
- Scigelova, 2009, Advances in bioanalytical LC–MS using the Orbitrap™ mass analyzer, Bioanalysis, 1, 741, 10.4155/bio.09.65 · doi:10.4155/bio.09.65
- Perry, 2008, Orbitrap mass spectrometry: Instrumentation, ion motion and applications, Mass Spectrom. Rev, 27, 661, 10.1002/mas.20186 · DOI · Paper page
- Makarov, 2000, Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis, Anal. Chem, 72, 1156, 10.1021/ac991131p · DOI · Paper page
- Makarov, 2006, Dynamic range of mass accuracy in LTQ orbitrap hybrid mass spectrometer, J. Am. Soc. Mass Spectrom, 17, 977, 10.1016/j.jasms.2006.03.006 · DOI · Paper page
- Schwartz, 2002, A two-dimensional quadrupole ion trap mass spectrometer, J. Am. Soc. Mass Spectrom, 13, 659, 10.1016/S1044-0305(02)00384-7 · DOI · Paper page
- Makarov, 2006, Performance evaluation of a hybrid linear ion trap/Orbitrap mass spectrometer, Anal. Chem, 78, 2113, 10.1021/ac0518811 · DOI · Paper page
- Olsen, 2005, Parts per million mass accuracy on an Orbitrap mass spectrometer via lock mass injection into a C-trap, Mol. Cell Proteomics, 4, 2010, 10.1074/mcp.T500030-MCP200 · DOI · Paper page
- Dernovics, 2008, Speciation analysis of selenium metabolites in yeast-based food supplements by ICPMS assisted hydrophilic interaction HPLC hybrid linear ion trap/Orbitrap MSn, Anal. Chem, 80, 3975, 10.1021/ac8002038 · DOI
- Erve, 2008, Rapid metabolite identification with sub parts-per-million mass accuracy from biological matrices by direct infusion nanoelectrospray ionization after clean-up on a ZipTip and LTQ/Orbitrap mass spectrometry, Rapid Commun. Mass Spectrom, 22, 3015, 10.1002/rcm.3702 · doi:10.1002/rcm.3702
- Scherl, 2008, On the benefits of acquiring peptide fragment ions at high measured mass accuracy, J. Am. Soc. Mass Spectrom, 19, 891, 10.1016/j.jasms.2008.02.005 · doi:10.1016/j.jasms.2008.02.005
- Bondarenko, 2009, Mass measurement and top-down HPLC/MS analysis of intact monoclonal antibodies on a hybrid linear quadrupole ion trap-Orbitrap mass spectrometer, J. Am. Soc. Mass Spectrom, 20, 1415, 10.1016/j.jasms.2009.03.020 · DOI
- Kaufmann, 1992, Secondary-ion generation from large keV molecular primary ions incident on a stainless-steel dynode, Rapid Commun. Mass Spectrom, 6, 98, 10.1002/rcm.1290060206 · doi:10.1002/rcm.1290060206
- Makarov, 2009, Performance evaluation of a high-field Orbitrap mass analyzer, J. Am. Soc. Mass Spectrom, 20, 1391, 10.1016/j.jasms.2009.01.005 · DOI · Paper page
- Beu, 2004, Broadband phase correction of FT-ICR mass spectra via simultaneous excitation and detection, Anal. Chem, 76, 5756, 10.1021/ac049733i · DOI
- Xian, 2010, Automated broadband phase correction of Fourier transform ion cyclotron resonance mass spectra, Anal. Chem, 82, 8807, 10.1021/ac101091w · DOI · Paper page
Cited by
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
Michalski, A., Damoc, E., Lange, O., Denisov, E., Nolting, D., Müller, M., Viner, R., Schwartz, J., Remes, P., Belford, M., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.013698 · Cited by 373
Self-citationIon Coalescence of Neutron Encoded TMT 10-Plex Reporter Ions
Werner, T., Sweetman, G., Savitski, M. F., Mathieson, T., Bantscheff, M., & Savitski, M. M. (2014) · Analytical Chemistry · doi:10.1021/ac500140s · Cited by 258
Evolution of Aromatic Structures during the Low-Temperature Electrochemical Upgrading of Bio-oil
Deng, W., Xu, K., Xiong, Z., Chaiwat, W., Wang, X., Su, S., Hu, S., Qiu, J., Wang, Y., & Xiang, J. (2019) · Energy & Fuels · doi:10.1021/acs.energyfuels.9b03099 · Cited by 180
Metadata
- Authors
- Scigelova, M., Hornshaw, M., Giannakopulos, A., & Makarov, A.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2011-07
- Volume
- 10
- Issue
- 7
- Pages
- M111.009431
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2048557976
- Cited by
- 224
- References
- 3
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by/4.0/ (vor, 3352 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fourier Transform Mass Spectrometry. https://app.cochat.ai/papers/10.1074/mcp.m111.009431
- The paper
- Scigelova, M., Hornshaw, M., Giannakopulos, A., & Makarov, A. (2011). Fourier Transform Mass Spectrometry. Molecular & Cellular Proteomics. https://doi.org/10.1074/mcp.m111.009431
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.