Multichannel mapping of fetal magnetocardiogram in an unshielded hospital setting
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To evaluate the feasibility of unshielded in-hospital multichannel mapping of fetal magnetocardiogram (FMCG), with a 36-channel system for standard adult magnetocardiographic (MCG) recordings, and its reliability according to the recommended standards for FMCG. METHODS: FMCG was ambulatory mapped with a 36-channel MCG system, in six normal pregnancies at different gestational ages. MCG analysis included adaptive digital filtering of 50 Hz, signal averaging, reconstruction of magnetic field distribution (MFD) and source localization. Fixed Point Independent Component Analysis algorithm (FastICA) was used to reconstruct the FMCG, separating them from maternal contamination and noise. RESULTS: The quality of FMCG recorded after the 32nd gestational week and reconstructed with FastICA was close to FMCG obtained in shielded rooms, and good enough to measure cardiac intervals and heart rate variability parameters. In two cases, reconstruction of the MFD during the QRS allowed three-dimensional localization of ventricular sources. CONCLUSIONS: A first demonstration has been given that multichannel mapping of FMCG can be performed in unshielded clinical environments, with resolution good enough for contactless assessment of fetal cardiac electrophysiology. FastICA processing on unshielded FMCG, recorded after the 32nd week, provided beat-to-beat analysis and heart rate variability assessment. Further work is needed to improve signal reconstruction in early pregnancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sympathovagal Balance: A Critical Appraisal
Eckberg, D. L. (1997) · Circulation · doi:10.1161/01.cir.96.9.3224 · Cited by 1,087 · cited 1×
“…to study the activity of the autonomic nervous system in adults (Task Force, 1996), although some doubts have been raised about the reliability of the LF (0.04–0.15 Hz) the HF (0.15–0.4 Hz) bands, as well as of the LF/HF ratio to unequivocally reflect the sympathovagal balance (Eckberg 1997).”
BackgroundInfluential(1974) · Journal of Perinatal Medicine · doi:10.1515/jpme.1974.2.3.214 · Cited by 112
Cited by
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Self-citationBrisinda, D., Caristo, M. E., & Fenici, R. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01048.2005 · Cited by 23
Self-citationSwain, P. P., Sengottuvel, S., Patel, R., Mani, A., & Gireesan, K. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101664 · Cited by 21
Brisinda, D., Caristo, M. E., & Fenici, R. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/8/002 · Cited by 9
Self-citation
Metadata
- Authors
- Brisinda, D., Comani, S., Meloni, A. M., Alleva, G., Mantini, D., & Fenici, R.
- Venue
- Prenatal Diagnosis
- Publisher
- Wiley
- Published
- 2005
- Volume
- 25
- Issue
- 5
- Pages
- 376-382
- ISSN
- 0197-3851 (ISSN-L)
- 1097-0223
- OpenAlex
- W2110121712
- Cited by
- 18
- References
- 2
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.