Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

Longitudinal study of cardiac electrical activity in anesthetized guinea pigs by contactless magnetocardiography

Brisinda, Donatella, Caristo, Maria Emiliana, Fenici, Riccardo · 2007 · Physiological Measurement

Abstract

Guinea pigs (GPs) are used for preclinical evaluation of electrophysiologic effects of new drugs, because their myocytes have human-like action potentials and ventricular repolarization's (VR) ion currents. This study was aimed to assess the reliability of magnetocardiographic (MCG) mapping for longitudinal studies of GP cardiac electrical activity. Eighteen anesthetized GPs were investigated with an unshielded 36-channel MCG instrumentation, at the age of 5 months (268.1 +/- 19 g). Twelve GPs survived and were restudied when 14 months old (595.6 +/- 90.5 g). RR, PR, QRS, QT(peak), QT(end), JT(peak), JT(end) and T(peak-end) intervals were measured from MCG waveforms. Magnetic field (MF) maps, equivalent current dipole (ECD) parameters and current density imaging were also analyzed. A significant prolongation of the PR (p < 0.05) and QRS (p < 0.001) intervals was found at 14 months. Gender-related differences of VR intervals were not significant. P(peak) and QRS(peak) MFs were similar in all animals, while T(peak) MF varied interindividually at 5 months and showed a rotation in some animals, at 14 months. The ECD strengths, measured at the P(peak), QRS(peak) and T(peak) were stronger (p < 0.01) at the age of 14 months than at 5 months. In contrast to findings in Wistar rats, age-related and gender-related differences of MCG VR parameters were not significant in GPs. Further work is necessary to clarify the variability of VR MF observed in healthy GPs.

Overview

Integrity signals

Registry

Crossref · 10.1088/0967-3334/28/8/002

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 50 references

Cited by

See all 9

Metadata

Authors
Brisinda, D., Caristo, M. E., & Fenici, R.
Affiliations
Università Cattolica del Sacro Cuore (IT)
Venue
Physiological Measurement
Published
2007-07-06
Volume
28
Issue
8
Pages
773-792
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W1995703101
Cited by
9
References
50
Citations by year
2025: 1 · 2024: 1 · 2023: 1 · 2022: 2 · 2020: 1 · 2012: 1
FWCI
0.23
Type
journal article
Language
en
Open access
closed
Locations
  • Physiological Measurement (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
Keywords
magnetocardiography, guinea pig, cardiac electrical activity, ventricular repolarization, equivalent current dipole, current density imaging, age-related changes, gender differences, PR interval, QRS duration, QT interval, T wave, longitudinal study, preclinical drug testing
MeSH terms
Aging, Anesthesia, Animals, Electrocardiography, Electrophysiology, Female, Guinea Pigs, Heart, Heart Rate, Longitudinal Studies, Male, Ventricular Function, Magnetocardiography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Longitudinal study of cardiac electrical activity in anesthetized guinea pigs by contactless magnetocardiography. https://app.cochat.ai/papers/10.1088/0967-3334/28/8/002
The paper
Brisinda, D., Caristo, M. E., & Fenici, R. (2007). Longitudinal study of cardiac electrical activity in anesthetized guinea pigs by contactless magnetocardiography. Physiological Measurement. https://doi.org/10.1088/0967-3334/28/8/002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.