CoChat

Spontaneously reported adverse reactions in association with complementary and alternative medicine substances in Sweden

Jacobsson, Ingela, Jönsson, Anna K, Gerdén, Barbro, Hägg, Staffan · 2009 · Pharmacoepidemiology and Drug Safety
Cited by 84

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Purpose: Although the safety information is limited, use of complementary and alternative medicine (CAM) products is not without risks. Spontaneous reporting systems may be used in the surveillance of these products. We describe the pattern of spontaneously reported CAM related adverse reactions submitted to the Swedish Medical Products Agency (MPA) and highlight areas of safety concern. Methods: All adverse reactions spontaneously reported to MPA between 1987 and 2006, where at least one CAM substance was a suspected agent, were scrutinised. From each report information about the patient, adverse reaction/s, drug treatment/s, dosage, time relationship and outcome was retrieved. Results: Among a total of 64 493 reports, 778 reports concerned 967 suspected adverse reactions related to 175 different CAM products. The main distribution of suspected adverse reactions was: urticaria (8.3%), exanthema (7.4%) and contact dermatitis (5.7%). The most reported CAM substances were purple coneflower (Echinacea purpurea) (8.1%), purple coneflower + siberian ginseng (Eleutherococcus senticosus) + malabar nut (Adhatoda vasica) (7.3%) and ginkgo leaf (Ginkgo biloba) (6.7%). In 221 reports, at least one reaction was categorised as serious, the most frequent being pulmonary embolism (1.7%), mixed liver reaction (2.8%), and anaphylactic reaction (2.0%). Eleven of the serious adverse reactions had a fatal outcome. Conclusions: CAM substances were associated with a variety of adverse reactions. Some of these have previously been unrecognised or poorly documented and suggest further investigations. By stimulating the reporting of adverse reactions of CAM products, the signal detection power of the spontaneous reporting system may increase further. Copyright © 2009 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/pds.1818

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 84

Metadata

Authors
Jacobsson, I., Jönsson, A. K., Gerdén, B., & Hägg, S.
Venue
Pharmacoepidemiology and Drug Safety
Publisher
Wiley
Published
2009-08-03
Volume
18
Issue
11
Pages
1039-1047
ISSN
  • 1053-8569 (ISSN-L)
  • 1099-1557
OpenAlex
W2059100719
Cited by
84
References
3
FWCI
19.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.