The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
A systematic review of validated methods for identifying atrial fibrillation using administrative data
Open accessAbstract
Purpose: The objectives of this study were to characterize the validity of algorithms to identify AF from electronic health data through a systematic review of the literature and to identify gaps needing further research. Methods: Two reviewers examined publications during 1997–2008 that identified patients with atrial fibrillation (AF) from electronic health data and provided validation information. We abstracted information including algorithm sensitivity, specificity, and positive predictive value (PPV). Results: We reviewed 544 abstracts and 281 full‐text articles, of which 18 provided validation information from 16 unique studies. Most used data from before 2000, and 10 of 16 used only inpatient data. Three studies incorporated electronic ECG data for case identification or validation. A large proportion of prevalent AF cases identified by ICD‐9 code 427.31 were valid (PPV 70%–96%, median 89%). Seven studies reported algorithm sensitivity (range, 57%–95%, median 79%). One study validated an algorithm for incident AF and reported a PPV of 77%. Conclusions: The ICD‐9 code 427.31 performed relatively well, but conclusions about algorithm validity are hindered by few recent data, use of nonrepresentative populations, and a disproportionate focus on inpatient data. An optimal contemporary algorithm would likely draw on inpatient and outpatient codes and electronic ECG data. Additional research is needed in representative, contemporary populations regarding algorithms that identify incident AF and incorporate electronic ECG data. Copyright © 2012 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Kannel, W. B., Wolf, P. A., Benjamin, E. J., & Levy, D. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00583-9 · Cited by 2,033
Incidence of and risk factors for atrial fibrillation in older adults
Psaty, B. M., Manolio, T. A., Kuller, L. H., Kronmal, R. A., Cushman, M., Fried, L. P., White, R., Furberg, C. D., & Rautaharju, P. M. (1997) · Circulation · doi:10.1161/01.cir.96.7.2455 · Cited by 1,462
Increasing Prevalence of Atrial Fibrillation and Flutter in the United States
Naccarelli, G. V., Varker, H., Lin, J., & Schulman, K. L. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.07.022 · Cited by 869
Go, A. S., Hylek, E. M., Borowsky, L. H., Phillips, K. A., Selby, J. V., & Singer, D. E. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-12-199912210-00004 · Cited by 585
Alonso, A., Agarwal, S. K., Soliman, E. Z., Ambrose, M., Chamberlain, A. M., Prineas, R. J., & Folsom, A. R. (2009) · American Heart Journal · doi:10.1016/j.ahj.2009.05.010 · Cited by 526
Gage, B. F., Boechler, M., Doggette, A. L., Fortune, G., Flaker, G. C., Rich, M. W., & Radford, M. J. (2000) · Stroke · doi:10.1161/01.str.31.4.822 · Cited by 302
Risk of New-Onset Atrial Fibrillation in Relation to Body Mass Index
Dublin, S. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.21.2322 · Cited by 266
Self-citation
Cited by
Alonso, A., Krijthe, B. P., Aspelund, T., Stepas, K. A., Pencina, M. J., Moser, C. B., Sinner, M. F., Sotoodehnia, N., Fontes, J. D., Janssens, A. C. J. W., et al. (2013) · Journal of the American Heart Association · doi:10.1161/jaha.112.000102 · Cited by 882
Self-citationSteinhubl, S. R., Waalen, J., Edwards, A. M., Ariniello, L. M., Mehta, R. R., Ebner, G. S., Carter, C., Baca-Motes, K., Felicione, E., Sarich, T., et al. (2018) · JAMA · doi:10.1001/jama.2018.8102 · Cited by 539
Yao, X., Abraham, N. S., Sangaralingham, L. R., Bellolio, M. F., McBane, R. D., Shah, N. D., & Noseworthy, P. A. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.116.003725 · Cited by 419
The U.S. Food and Drug Administration's Mini‐Sentinel program: status and direction
Platt, R., Carnahan, R. M., Brown, J. S., Chrischilles, E., Curtis, L. H., Hennessy, S., Nelson, J. C., Racoosin, J. A., Robb, M., Schneeweiss, S., et al. (2012) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.2343 · Cited by 287
Self-citationSoliman, E. Z., Lopez, F., O’Neal, W. T., Chen, L. Y., Bengtson, L., Zhang, Z.-M., Loehr, L., Cushman, M., & Alonso, A. (2015) · Circulation · doi:10.1161/circulationaha.114.014145 · Cited by 174
Metadata
- Authors
- Jensen, P. N., Johnson, K., Floyd, J., Heckbert, S. R., Carnahan, R., & Dublin, S.
- Venue
- Pharmacoepidemiology and Drug Safety
- Publisher
- Wiley
- Published
- 2012-01
- Volume
- 21
- Issue
- S1
- Pages
- 141-147
- ISSN
- 1053-8569 (ISSN-L)
- 1099-1557
- OpenAlex
- W1539721984
- Cited by
- 339
- References
- 22
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- bronze
- Funders
- Food and Drug Administration (HHSF223200910006I, NHLBI HL068986, T32HL007902)
- Group Health Research Institute internal funds (NIA K23AG028954)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A systematic review of validated methods for identifying atrial fibrillation using administrative data. https://app.cochat.ai/papers/10.1002/pds.2317
- The paper
- Jensen, P. N., Johnson, K., Floyd, J., Heckbert, S. R., Carnahan, R., & Dublin, S. (2012). A systematic review of validated methods for identifying atrial fibrillation using administrative data. Pharmacoepidemiology and Drug Safety. https://doi.org/10.1002/pds.2317
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.