The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
The human serum proteome: Display of nearly 3700 chromatographically separated protein spots on two‐dimensional electrophoresis gels and identification of 325 distinct proteins
Abstract
Plasma, the soluble component of the human blood, is believed to harbor thousands of distinct proteins, which originate from a variety of cells and tissues through either active secretion or leakage from blood cells or tissues. The dynamic range of plasma protein concentrations comprises at least nine orders of magnitude. Proteins involved in coagulation, immune defense, small molecule transport, and protease inhibition, many of them present in high abundance in this body fluid, have been functionally characterized and associated with disease processes. For example, protein sequence mutations in coagulation factors cause various serious disease states. Diagnosing and monitoring such diseases in blood plasma of affected individuals has typically been conducted by use of enzyme‐linked immunosorbent assays, which using a specific antibody quantitatively measure only the affected protein in the tested plasma samples. The discovery of protein biomarkers in plasma for diseases with no known correlations to genetic mutations is challenging. It requires a highly parallel display and quantitation strategy for proteins. We fractionated blood serum proteins prior to display on two‐dimensional electrophoresis (2‐DE) gels using immunoaffinity chromatography to remove the most abundant serum proteins, followed by sequential anion‐exchange and size‐exclusion chromatography. Serum proteins from 74 fractions were displayed on 2‐DE gels. This approach succeeded in resolving approximately 3700 distinct protein spots, many of them post‐translationally modified variants of plasma proteins. About 1800 distinct serum protein spots were identified by mass spectrometry. They collapsed into 325 distinct proteins, after sequence homology and similarity searches were carried out to eliminate redundant protein annotations. Although a relatively insensitive dye, Coomassie Brillant Blue G‐250, was used to visualize protein spots, several proteins known to be present in serum in < 10 ng/mL concentrations were identified such as interleukin‐6, cathepsins, and peptide hormones. Considering that our strategy allows highly parallel protein quantitation on 2‐DE gels, it holds promise to accelerate the discovery of novel serum protein biomarkers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High resolution two-dimensional electrophoresis of proteins.
O'Farrell, P. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41496-8 · Cited by 19,246
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Self-citationUse of proteomic patterns in serum to identify ovarian cancer
Petricoin, E. F., Ardekani, A. M., Hitt, B. A., Levine, P. J., Fusaro, V. A., Steinberg, S. M., Mills, G. B., Simone, C., Fishman, D. A., Kohn, E. C., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07746-2 · Cited by 3,236
Analysis of Proteins and Proteomes by Mass Spectrometry
Mann, M., Hendrickson, R. C., & Pandey, A. (2001) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.70.1.437 · Cited by 1,219
Klose, J. (1975) · Humangenetik · doi:10.1007/bf00281458 · Cited by 1,207
MACK, H. C. (1960) · Clinical Obstetrics and Gynecology · doi:10.1097/00003081-196006000-00007 · Cited by 925
Furlan, M., Robles, R., & Lamie, B. (1996) · Blood · doi:10.1182/blood.v87.10.4223.bloodjournal87104223 · Cited by 895
Toward a Human Blood Serum Proteome
Adkins, J. N., Varnum, S. M., Auberry, K. J., Moore, R. J., Angell, N. H., Smith, R. D., Springer, D. L., & Pounds, J. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200066-mcp200 · Cited by 793
Mass spectrometry and the age of the proteome
Yates, J. R. (1998) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199801)33:1<1::aid-jms624>3.0.co;2-9 · Cited by 752
Inflammatory bio‐markers and cardiovascular risk prediction
Blake, G. J., & Ridker, P. M. (2002) · Journal of Internal Medicine · doi:10.1046/j.1365-2796.2002.01019.x · Cited by 702
High resolution two-dimensional electrophoresis of human plasma proteins.
Anderson, L., & Anderson, N. G. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.12.5421 · Cited by 648
Self-citationSahu, A., & Lambris, J. D. (2001) · Immunological Reviews · doi:10.1034/j.1600-065x.2001.1800103.x · Cited by 525
Katus, H. (1989) · Journal of Molecular and Cellular Cardiology · doi:10.1016/0022-2828(89)90680-9 · Cited by 461
Gatlin, C. L., Kleemann, G. R., Hays, L. G., Link, A. J., & Yates, J. R. (1998) · Analytical Biochemistry · doi:10.1006/abio.1998.2809 · Cited by 391
Self-citationMass spectrometric approaches for the identification of gel‐separated proteins
Patterson, S. D., & Aebersold, R. (1995) · ELECTROPHORESIS · doi:10.1002/elps.11501601299 · Cited by 378
Pieper, R., Su, Q., Gatlin, C. L., Huang, S., Anderson, N. L., & Steiner, S. (2003) · PROTEOMICS · doi:10.1002/pmic.200390057 · Cited by 356
Self-citationBerchem, G., Glondu, M., Gleizes, M., Brouillet, J.-P., Vignon, F., Garcia, M., & Liaudet-Coopman, E. (2002) · Oncogene · doi:10.1038/sj.onc.1205745 · Cited by 258
Görg, A., Obermaier, C., Boguth, G., & Weiss, W. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19990101)20:4/5<712::aid-elps712>3.0.co;2-y · Cited by 247
Sanchez, J., Appel, R. D., Golaz, O., Pasquali, C., Ravier, F., Bairoch, A., & Hochstrasser, D. F. (1995) · ELECTROPHORESIS · doi:10.1002/elps.11501601190 · Cited by 227
Wall, D. B., Kachman, M. T., Gong, S., Hinderer, R., Parus, S., Misek, D. E., Hanash, S. M., & Lubman, D. M. (2000) · Analytical Chemistry · doi:10.1021/ac991332t · Cited by 213
Composition of the peptide fraction in human blood plasma: database of circulating human peptides
Richter, R., Schulz-Knappe, P., Schrader, M., Ständker, L., Jürgens, M., Tammen, H., & Forssmann, W.-G. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00012-2 · Cited by 193
Kos, J., Werle, B., Lah, T., & Brunner, N. (2000) · The International Journal of Biological Markers · doi:10.1177/172460080001500116 · Cited by 180
Plasma protein map: An update by microsequencing
Hughes, G. J., Frutiger, S., Paquet, N., Ravier, F., Pasquali, C., Sanchez, J., James, R., Tissot, J., Bjellqvist, B., & Hochstrasser, D. F. (1992) · Electrophoresis · doi:10.1002/elps.11501301150 · Cited by 136
Wu, S., Amato, H., Biringer, R. G., Choudhary, G., Shieh, P., & Hancock, W. S. (2002) · Journal of Proteome Research · doi:10.1021/pr025537l · Cited by 123
Badock, V., Steinhusen, U., Bommert, K., & Otto, A. (2001) · Electrophoresis · doi:10.1002/1522-2683(200108)22:14<2856::aid-elps2856>3.0.co;2-u · Cited by 77
Zachara, B., Trafikowska, U., Adamowicz, A., Nartowicz, E., & Manitius, J. (2001) · Journal of Trace Elements in Medicine and Biology · doi:10.1016/s0946-672x(01)80061-4 · Cited by 45
Steiner, S., Gatlin, C. L., Lennon, J. J., McGrath, A. M., Seonarain, M., Makusky, A. J., Aponte, A. M., Esquer‐Blasco, R., & Anderson, N. L. (2001) · Toxicology Letters · doi:10.1016/s0378-4274(01)00268-5 · Cited by 36
Self-citation
Cited by
Anderson, N. L., Polanski, M., Pieper, R., Gatlin, T., Tirumalai, R. S., Conrads, T. P., Veenstra, T. D., Adkins, J. N., Pounds, J. G., Fagan, R., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m300127-mcp200 · Cited by 1,006
Self-citationOmenn, G. S., States, D. J., Adamski, M., Blackwell, T. W., Menon, R., Hermjakob, H., Apweiler, R., Haab, B. B., Simpson, R. J., Eddes, J. S., et al. (2005) · PROTEOMICS · doi:10.1002/pmic.200500358 · Cited by 787
Nanoparticle–Cell Interactions: Molecular Structure of the Protein Corona and Cellular Outcomes
Fleischer, C. C., & Payne, C. K. (2014) · Accounts of Chemical Research · doi:10.1021/ar500190q · Cited by 575
Human body fluid proteome analysis
Hu, S., Loo, J. A., & Wong, D. T. (2006) · PROTEOMICS · doi:10.1002/pmic.200600284 · Cited by 533
Sensing of proteins in human serum using conjugates of nanoparticles and green fluorescent protein
De, M., Rana, S., Akpinar, H., Miranda, O. R., Arvizo, R. R., Bunz, U. H. F., & Rotello, V. M. (2009) · Nature Chemistry · doi:10.1038/nchem.334 · Cited by 488
Metadata
- Authors
- Pieper, R., Gatlin, C. L., Makusky, A. J., Russo, P. S., Schatz, C. R., Miller, S. S., Su, Q., McGrath, A. M., Estock, M. A., Parmar, P. P., Zhao, M., Huang, S., Zhou, J., Wang, F., Esquer‐Blasco, R., Anderson, N. L., Taylor, J., & Steiner, S.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2003-07
- Volume
- 3
- Issue
- 7
- Pages
- 1345-1364
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2002396315
- Cited by
- 518
- References
- 28
- FWCI
- 21.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.