The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A comprehensive approach to the analysis of matrix‐assisted laser desorption/ionization‐time of flight proteomics spectra from serum samples
Abstract
For our analysis of the data from the First Annual Proteomics Data Mining Conference, we attempted to discriminate between 24 disease spectra (group A) and 17 normal spectra (group B). First, we processed the raw spectra by (i) correcting for additive sinusoidal noise (periodic on the time scale) affecting most spectra, (ii) correcting for the overall baseline level, (iii) normalizing, (iv) recombining fractions, and (v) using variable‐width windows for data reduction. Also, we identified a set of polymeric peaks (at multiples of 180.6 Da) that is present in several normal spectra (B1–B8). After data processing, we found the intensities at the following mass to charge ( m/z ) values to be useful discriminators: 3077, 12 886 and 74 263. Using these values, we were able to achieve an overall classification accuracy of 38/41 (92.6%). Perfect classification could be achieved by adding two additional peaks, at 2476 and 6955. We identified these values by applying a genetic algorithm to a filtered list of m/z values using Mahalanobis distance between the group means as a fitness function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of proteomic patterns in serum to identify ovarian cancer
Petricoin, E. F., Ardekani, A. M., Hitt, B. A., Levine, P. J., Fusaro, V. A., Steinberg, S. M., Mills, G. B., Simone, C., Fishman, D. A., Kohn, E. C., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07746-2 · Cited by 3,236
Cited by
Bias as a threat to the validity of cancer molecular-marker research
Ransohoff, D. F. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1550 · Cited by 487
Label-free, normalized quantification of complex mass spectrometry data for proteomic analysis
Griffin, N. M., Yu, J., Long, F., Oh, P., Shore, S., Li, Y., Koziol, J. A., & Schnitzer, J. E. (2010) · Nature Biotechnology · doi:10.1038/nbt.1592 · Cited by 402
A data review and re-assessment of ovarian cancer serum proteomic profiling
Sorace, J. M., & Zhan, M. (2003) · BMC Bioinformatics · doi:10.1186/1471-2105-4-24 · Cited by 336
Coombes, K. R., Tsavachidis, S., Morris, J. S., Baggerly, K. A., Hung, M., & Kuerer, H. M. (2005) · PROTEOMICS · doi:10.1002/pmic.200401261 · Cited by 328
Self-citationMorris, J. S., Coombes, K. R., Koomen, J., Baggerly, K. A., & Kobayashi, R. (2005) · Bioinformatics · doi:10.1093/bioinformatics/bti254 · Cited by 315
Self-citation
Metadata
- Authors
- Baggerly, K. A., Morris, J. S., Wang, J., Gold, D., Xiao, L., & Coombes, K. R.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2003-09
- Volume
- 3
- Issue
- 9
- Pages
- 1667-1672
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2120501961
- Cited by
- 167
- References
- 1
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.