The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Antibody microarrays: An evaluation of production parameters
Abstract
Antibody microarrays could have an enormous impact on the functional analysis of cellular activity and regulation, especially at the level of protein expression and protein‐protein interaction, and might become an invaluable tool in disease diagnostics. The array surface is bound to have a tremendous influence on the findings from such studies. Apart from the basic issue of how to attach antibodies optimally without affecting their function, it is also important that the cognate antigens, applied within a complex protein mixture, all bind to the arrayed antibodies irrespective of their enormous variety in structure. In this study, various factors in the production of antibody microarrays on glass support were analysed: the modification of the glass surface; kind and length of cross‐linkers; composition and pH of the spotting buffer; blocking reagents; antibody concentration and storage procedures, in order to evaluate their effect on array performance. Altogether, data from more than 700 individual array experiments were taken into account. In addition to home‐made slides, commercially available systems were also included in the analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Correlation between Protein and mRNA Abundance in Yeast
Gygi, S. P., Rochon, Y., Franza, B. R., & Aebersold, R. (1999) · Molecular and Cellular Biology · doi:10.1128/mcb.19.3.1720 · Cited by 3,819
Printing Proteins as Microarrays for High-Throughput Function Determination
MacBeath, G., & Schreiber, S. L. (2000) · Science · doi:10.1126/science.289.5485.1760 · Cited by 2,767
(1996) · Elsevier eBooks · doi:10.1016/b978-0-12-342335-1.x5000-3 · Cited by 1,016
Haab, B. B., Dunham, M. J., & Brown, P. O. (2001) · Genome Biology · doi:10.1186/gb-2001-2-2-research0004 · Cited by 892
Analysis of yeast protein kinases using protein chips
Zhu, H., Klemic, J. F., Chang, S., Bertone, P., Casamayor, A., Klemic, K. G., Smith, D., Gerstein, M., Reed, M. A., & Snyder, M. (2000) · Nature Genetics · doi:10.1038/81576 · Cited by 797
Autoantigen microarrays for multiplex characterization of autoantibody responses
Robinson, W. H., DiGennaro, C., Hueber, W., Haab, B. B., Kamachi, M., Dean, E. J., Fournel, S., Fong, D., Genovese, M. C., De Vegvar, H. E. N., et al. (2002) · Nature Medicine · doi:10.1038/nm0302-295 · Cited by 673
Schweitzer, B., Wiltshire, S., Lambert, J., O'Malley, S., Kukanskis, K., Zhu, Z., Kingsmore, S. F., Lizardi, P. M., & Ward, D. C. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170237197 · Cited by 597
Richards, A. B., Krakowka, S., Dexter, L. B., Schmid, H., Wolterbeek, A. P. M., Waalkens-Berendsen, D. H., Shigoyuki, A., & Kurimoto, M. (2002) · Food and Chemical Toxicology · doi:10.1016/s0278-6915(02)00011-x · Cited by 593
Printing Small Molecules as Microarrays and Detecting Protein−Ligand Interactions en Masse
MacBeath, G., Koehler, A. N., & Schreiber, S. L. (1999) · Journal of the American Chemical Society · doi:10.1021/ja991083q · Cited by 420
Bhatia, S. K., Shriver-Lake, L. C., Prior, K. J., Georger, J. H., Calvert, J. M., Bredehorst, R., & Ligler, F. S. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90662-3 · Cited by 365
Cited by
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Chemical Strategies for Generating Protein Biochips
Jonkheijm, P., Weinrich, D., Schröder, H., Niemeyer, C. M., & Waldmann, H. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200801711 · Cited by 590
Vashist, S. K., Lam, E., Hrapovic, S., Male, K. B., & Luong, J. H. T. (2014) · Chemical Reviews · doi:10.1021/cr5000943 · Cited by 345
Progress in protein and antibody microarray technology
Angenendt, P. (2005) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03392-1 · Cited by 289
Hall, D. A., Ptacek, J., & Snyder, M. (2007) · Mechanisms of Ageing and Development · doi:10.1016/j.mad.2006.11.021 · Cited by 286
Metadata
- Authors
- Kusnezow, W., Jacob, A., Walijew, A., Diehl, F., & Hoheisel, J. D.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2003-03
- Volume
- 3
- Issue
- 3
- Pages
- 254-264
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2035812229
- Cited by
- 299
- References
- 23
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antibody microarrays: An evaluation of production parameters. https://app.cochat.ai/papers/10.1002/pmic.200390038
- The paper
- Kusnezow, W., Jacob, A., Walijew, A., Diehl, F., & Hoheisel, J. D. (2003). Antibody microarrays: An evaluation of production parameters. PROTEOMICS. https://doi.org/10.1002/pmic.200390038
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.