The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Improved peak detection and quantification of mass spectrometry data acquired from surface‐enhanced laser desorption and ionization by denoising spectra with the undecimated discrete wavelet transform
Abstract
Mass spectrometry is being used to find disease‐related patterns in mixtures of proteins derived from biological fluids. Questions have been raised about the reproducibility and reliability of peak quantifications using this technology. We collected nipple aspirate fluid from breast cancer patients and healthy women, pooled them into a quality control sample, and produced 24 replicate SELDI spectra. We developed a novel algorithm to process the spectra, denoising with the undecimated discrete wavelet transform (UDWT), and evaluated it for consistency and reproducibility. UDWT efficiently decomposes spectra into noise and signal. The noise is consistent and uncorrelated. Baseline correction produces isolated peak clusters separated by flat regions. Our method reproducibly detects more peaks than the method implemented in Ciphergen software. After normalization and log transformation, the mean coefficient of variation of peak heights is 10.6%. Our method to process spectra provides improvements over existing methods. Denoising using the UDWT appears to be an important step toward obtaining results that are more accurate. It improves the reproducibility of quantifications and supplies tools for investigation of the variations in the technology more carefully. Further study will be required, because we do not have a gold standard providing an objective assessment of which peaks are present in the samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of proteomic patterns in serum to identify ovarian cancer
Petricoin, E. F., Ardekani, A. M., Hitt, B. A., Levine, P. J., Fusaro, V. A., Steinberg, S. M., Mills, G. B., Simone, C., Fishman, D. A., Kohn, E. C., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07746-2 · Cited by 3,236
Translation-Invariant De-Noising
Coifman, R. R., & Donoho, D. L. (1995) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-2544-7_9 · Cited by 1,914
New desorption strategies for the mass spectrometric analysis of macromolecules
Hutchens, T. W., & Yip, T. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290070703 · Cited by 621
Baggerly, K. A., Morris, J. S., & Coombes, K. R. (2004) · Bioinformatics · doi:10.1093/bioinformatics/btg484 · Cited by 621
Self-citation(1995) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-2544-7 · Cited by 569
Kingsbury, N. G. (1998) · Cited by 552
Noise reduction using an undecimated discrete wavelet transform
Lang, M., Guo, H., Odegard, J. E., Burrus, C. S., & Wells, R. O. (1996) · IEEE Signal Processing Letters · doi:10.1109/97.475823 · Cited by 484
A data review and re-assessment of ovarian cancer serum proteomic profiling
Sorace, J. M., & Zhan, M. (2003) · BMC Bioinformatics · doi:10.1186/1471-2105-4-24 · Cited by 336
Schaub, S., Wilkins, J., Weiler, T., Sangster, K., Rush, D., & Nickerson, P. (2004) · Kidney International · doi:10.1111/j.1523-1755.2004.00352.x · Cited by 328
Noise reduction for magnetic resonance images via adaptive multiscale products thresholding
Bao, P., & Zhang, L. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.816958 · Cited by 295
Paweletz, C. P., Trock, B., Pennanen, M., Tsangaris, T., Magnant, C., Liotta, L. A., & Petricoin, E. F. (2001) · Disease Markers · doi:10.1155/2001/674959 · Cited by 285
Yasui, Y. (2003) · Biostatistics · doi:10.1093/biostatistics/4.3.449 · Cited by 254
Rogers, M. A., Clarke, P. A., Noble, J., Munro, N. P., Paul, A., Selby, P. J., & Banks, R. E. (2003) · PubMed · Cited by 220
Coombes, K. R., Fritsche, H. A., Clarke, C., Chen, J.-N., Baggerly, K. A., Morris, J. S., Xiao, L.-C., Hung, M.-C., & Kuerer, H. M. (2003) · Clinical Chemistry · doi:10.1373/49.10.1615 · Cited by 216
Self-citationAdam, P. J., Boyd, R., Tyson, K. L., Fletcher, G. C., Stamps, A., Hudson, L., Poyser, H. R., Redpath, N., Griffiths, M., Steers, G., et al. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m210184200 · Cited by 208
Zhukov, T. A., Johanson, R. A., Cantor, A. B., Clark, R. A., & Tockman, M. S. (2003) · Lung Cancer · doi:10.1016/s0169-5002(03)00082-5 · Cited by 184
Baggerly, K. A., Morris, J. S., Wang, J., Gold, D., Xiao, L., & Coombes, K. R. (2003) · PROTEOMICS · doi:10.1002/pmic.200300522 · Cited by 167
Self-citationProteinChip ® Clinical Proteomics: Computational Challenges and Solutions
Fung, E. T., & Enderwick, C. (2002) · BioTechniques · doi:10.2144/mar0205 · Cited by 139
ProteinChip clinical proteomics: computational challenges and solutions.
Fung, E. T., & Enderwick, C. (2002) · PubMed · Cited by 132
Diedrich, A., Charoensuk, W., Brychta, R. J., Ertl, A. C., & Shiavi, R. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.807323 · Cited by 132
Proteomic analysis of nipple aspirate fluid to detect biologic markers of breast cancer
Sauter, E. R., Zhu, W., Fan, X.-J., Wassell, R. P., Chervoneva, I., & Bois, G. C. D. (2002) · British Journal of Cancer · doi:10.1038/sj.bjc.6600285 · Cited by 127
Qu, Y., Adam, B.-L., Thornquist, M. D., Potter, J. D., Thompson, M. L., Yasui, Y., Davis, J. W., Schellhammer, P. F., Cazares, L. H., Clements, M., et al. (2003) · Biometrics · doi:10.1111/1541-0420.00017 · Cited by 80
Pharmacogenomics of cytochrome P450 and other enzymes involved in biotransformation of xenobiotics
Guengerich, F. P. (2000) · Drug Development Research · doi:10.1002/(sici)1098-2299(200001)49:1<34::aid-ddr6>3.0.co;2-w · Cited by 30
Placidi, G., Alecci, M., & Sotgiu, A. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/13/310 · Cited by 27
Cited by
Du, P., Kibbe, W. A., & Lin, S. M. (2006) · Bioinformatics · doi:10.1093/bioinformatics/btl355 · Cited by 763
Human body fluid proteome analysis
Hu, S., Loo, J. A., & Wong, D. T. (2006) · PROTEOMICS · doi:10.1002/pmic.200600284 · Cited by 533
An Efficient Algorithm for Automatic Peak Detection in Noisy Periodic and Quasi-Periodic Signals
Scholkmann, F., Boss, J., & Wolf, M. (2012) · Algorithms · doi:10.3390/a5040588 · Cited by 453
Optimal Choice of Baseline Correction for Multivariate Calibration of Spectra
Liland, K. H., Almøy, T., & Mevik, B.-H. (2010) · Applied Spectroscopy · doi:10.1366/000370210792434350 · Cited by 317
Morris, J. S., Coombes, K. R., Koomen, J., Baggerly, K. A., & Kobayashi, R. (2005) · Bioinformatics · doi:10.1093/bioinformatics/bti254 · Cited by 315
Self-citation
Metadata
- Authors
- Coombes, K. R., Tsavachidis, S., Morris, J. S., Baggerly, K. A., Hung, M., & Kuerer, H. M.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2005-10-27
- Volume
- 5
- Issue
- 16
- Pages
- 4107-4117
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2123989476
- Cited by
- 328
- References
- 24
- FWCI
- 14.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.