Capture and analysis of quantitative proteomic data
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Whilst the array of techniques available for quantitative proteomics continues to grow, the attendant bioinformatic software tools are similarly expanding in number. The data capture and analysis of such quantitative data is obviously crucial to the experiment and the methods used to process it will critically affect the quality of the data obtained. These tools must deal with a variety of issues, including identification of labelled and unlabelled peptide species, location of the corresponding MS scans in the experiment, construction of representative ion chromatograms, location of the true peptide ion chromatogram start and end, elimination of background signal in the mass spectrum and chromatogram and calculation of both peptide and protein ratios/abundances. A variety of tools and approaches are available, in part restricted by the nature of the experiment to be performed and available instrumentation. Currently, although there is no single consensus on precisely how to calculate protein and peptide abundances, many common themes have emerged which identify and reduce many of the key sources of error. These issues will be discussed, along with those relating to deposition of quantitative data. At present, mature data standards for quantitative proteomics are not yet available, although formats are beginning to emerge.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733
Proteomic characterization of the human centrosome by protein correlation profiling
Andersen, J. S., Wilkinson, C. J., Mayor, T., Mortensen, P., Nigg, E. A., & Mann, M. (2003) · Nature · doi:10.1038/nature02166 · Cited by 1,319
Lu, P., Vogel, C., Wang, R., Yao, X., & Marcotte, E. M. (2007) · Nature Biotechnology · doi:10.1038/nbt1270 · Cited by 1,139
Interpretation of Shotgun Proteomic Data
Nesvizhskii, A. I., & Aebersold, R. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r500012-mcp200 · Cited by 1,025
Barr, J. R., Maggio, V. L., Patterson, D. G., Cooper, G. R., Henderson, L. O., Turner, W. E., Smith, S. J., Hannon, W. H., Needham, L. L., & Sampson, E. J. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.10.1676 · Cited by 347
Cited by
Correlation of mRNA and protein in complex biological samples
Maier, T., Güell, M., & Serrano, L. (2009) · FEBS Letters · doi:10.1016/j.febslet.2009.10.036 · Cited by 1,802
“A large variety of MS data analysis software packages exist, also comprising statistical tools for data analysis (for an overview see [81,83–85]).”
Analysis of protein carbonylation — pitfalls and promise in commonly used methods
Rogowska-Wrzesinska, A., Wojdyla, K., Nedić, O., Baron, C. P., & Griffiths, H. R. (2014) · Free Radical Research · doi:10.3109/10715762.2014.944868 · Cited by 65
Forshed, J., Johansson, H. J., Pernemalm, M., Branca, R. M. M., Sandberg, A., & Lehtiö, J. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.010264 · Cited by 32
“Several open source/academic and commercial software for quantitative analysis of proteomics MS/MS data are available supporting different MS instruments and labeling methods (20, 22–25).”
Background
Metadata
- Authors
- Lau, K. W., Jones, A. R., Swainston, N., Siepen, J. A., & Hubbard, S. J.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2007-08
- Volume
- 7
- Issue
- 16
- Pages
- 2787-2799
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W1994047343
- Cited by
- 50
- References
- 5
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.