Isotope dilution--mass spectrometric quantification of specific proteins: model application with apolipoprotein A-I
Abstract
An enzymatic hydrolysis isotope dilution-mass spectrometric method was developed for reference quantification of specific proteins. The analytical procedure involved measuring a reproducibly hydrolyzed peptide (serving as the primary standard) unique to a specific protein. This new mass spectrometric method was evaluated by assessing the concentration of apolipoprotein (apo) A-I in the European Community Bureau of Reference (BCR) lyophilized Certified Reference Material (CRM 393). We used the method to make 96 measurements (4 replicate analyses of 4 enzymatic digests of 6 vials of BCR-CRM 393), which gave an average total protein mass of 1.048 mg (+/- 1.0% at 99% confidence limits). The total overall analytical CV was 3.95%. The results of this evaluation of our model approach to determine the concentration of a specific protein in a purified preparation demonstrated that our new mass spectrometric method can be used to measure apolipoproteins and other specific proteins without the use of epitopic immunoassay methods.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Various LC-MS/MS assays for multiplexed quantification of apolipoproteins or phenotyping of apoE have been reported.
“Various LC-MS/MS assays for multiplexed quantification of apolipoproteins (14-23) or phenotyping of apoE (24-27) have been reported.”
From Automated multiplex LC-MS/MS assay for quantifying serum apolipoproteins A-I, B, C-I, C-II, C-III, and E with qualitative apolipoprotein E phenotyping (2016) · cites this paper as [23]
Cited by
Sorted by citations
Ishihama, Y., Oda, Y., Tabata, T., Sato, T., Nagasu, T., Rappsilber, J., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500061-mcp200 · Cited by 2,055 · see citing works
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867 · see citing works
Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733 · see citing works
Addona, T. A., Abbatiello, S. E., Schilling, B., Skates, S. J., Mani, D. R., Bunk, D. M., Spiegelman, C. H., Zimmerman, L. J., Ham, A.-J. L., Keshishian, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1546 · Cited by 1,037 · see citing works
Carr, S. A., Abbatiello, S. E., Ackermann, B. L., Borchers, C., Domon, B., Deutsch, E. W., Grant, R. P., Hoofnagle, A. N., Hüttenhain, R., Koomen, J. M., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.036095 · Cited by 561 · see citing works
Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer
Gallien, S., Duriez, E., Crone, C., Kellmann, M., Moehring, T., & Domon, B. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.019802 · Cited by 510 · see citing works
Global changes to the ubiquitin system in Huntington's disease
Bennett, E. J., Shaler, T. A., Woodman, B., Ryu, K.-Y., Zaitseva, T. S., Becker, C. H., Bates, G. P., Schulman, H., & Kopito, R. R. (2007) · Nature · doi:10.1038/nature06022 · Cited by 497 · see citing works
Hoofnagle, A. N., Becker, J. O., Wener, M. H., & Heinecke, J. W. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.109652 · Cited by 314 · see citing works
Chung, C.-S., Chen, C.-H., Ho, M.-Y., Huang, C.-Y., Liao, C.-L., & Chang, W. (2006) · Journal of Virology · doi:10.1128/jvi.80.5.2127-2140.2006 · Cited by 253 · see citing works
van den Broek, I., Romijn, F. P. H. T. M., Nouta, J., van der Laarse, A., Drijfhout, J. W., Smit, N. P. M., van der Burgt, Y. E. M., & Cobbaert, C. M. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.246702 · Cited by 105 · see citing works
Carvalho, V. M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.08.027 · Cited by 90 · see citing works
Lassman, M. E., McLaughlin, T. M., Somers, E. P., Stefanni, A. C., Chen, Z., Murphy, B. A., Bierilo, K. K., Flattery, A. M., Wong, K. K., Castro‐Perez, J. M., et al. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5296 · Cited by 51 · see citing works
Clouet-Foraison, N., Gaie-Levrel, F., Gillery, P., & Delatour, V. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0091 · Cited by 30 · see citing works
- Authors
- Barr, J. R., Maggio, V. L., Patterson, D. G., Cooper, G. R., Henderson, L. O., Turner, W. E., Smith, S. J., Hannon, W. H., Needham, L. L., & Sampson, E. J.
- Affiliations
- Centers for Disease Control and Prevention (US)
- ORCID
- Barr, J R
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-10-01
- Volume
- 42
- Issue
- 10
- Pages
- 1676-1682
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1892810170
- Cited by
- 347
- References
- 0
- Citations by year
- 2026: 4 · 2024: 1 · 2023: 2 · 2022: 4 · 2021: 5 · 2020: 4 · 2019: 4 · 2018: 1 · 2017: 16 · 2016: 19 · 2015: 20 · 2014: 29 · 2013: 26 · 2012: 34
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Clinical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
- Keywords
- isotope dilution mass spectrometry, apolipoprotein A-I, protein quantification, enzymatic hydrolysis, certified reference materials, apolipoproteins, reference measurement procedure
- MeSH terms
- Amino Acid Sequence, Humans, Hydrolysis, Indicator Dilution Techniques, Molecular Sequence Data, Molecular Weight, Peptide Fragments, Peptide Mapping, Mass Spectrometry, Trypsin, Spectrometry, Mass, Fast Atom Bombardment, Apolipoprotein A-I
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review