Integrating titania enrichment, iTRAQ labeling, and Orbitrap CID‐HCD for global identification and quantitative analysis of phosphopeptides
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Recent advances in MS instrumentation and progresses in phosphopeptide enrichment, in conjunction with more powerful data analysis tools, have facilitated unbiased characterization of thousands of site‐specific phosphorylation events. Combined with stable isotope labeling by amino acids in cell culture metabolic labeling, these techniques have made it possible to quantitatively evaluate phosphorylation changes in various physiological states in stable cell lines. However, quantitative phosphoproteomics in primary cells and tissues remains a major technical challenge due to the lack of adequate techniques for accurate quantification. Here, we describe an integrated strategy allowing for large scale quantitative profiling of phosphopeptides in complex biological mixtures. In this technique, the mixture of proteolytic peptides was subjected to phosphopeptide enrichment using a titania affinity column, and the purified phosphopeptides were subsequently labeled with iTRAQ reagents. After further fractionation by strong‐cation exchange, the peptides were analyzed by LC‐MS/MS on an Orbitrap mass spectrometer, which collects CID and high‐energy collisional dissociation (HCD) spectra sequentially for peptide identification and quantitation. We demonstrate that direct phosphopeptide enrichment of protein digests by titania affinity chromatography substantially improves the efficiency and reproducibility of phosphopeptide proteomic analysis and is compatible with downstream iTRAQ labeling. Conditions were optimized for HCD normalized collision energy to balance the overall peptide identification and quantitation using the relative abundances of iTRAQ reporter ions. Using this approach, we were able to identify 3557 distinct phosphopeptides from HeLa cell lysates, of which 2709 were also quantified from HCD scans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572 · cited 1×
“A wide range of different chemical and biological derivatization reagents have been adapted to evaluate relative abundance of phosphorylation [19, 20].”
BackgroundFunctional and quantitative proteomics using SILAC
Mann, M. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2067 · Cited by 931
Large-scale phosphorylation analysis of mouse liver
Villén, J., Beausoleil, S. A., Gerber, S. A., & Gygi, S. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609836104 · Cited by 730
A Multidimensional Chromatography Technology for In-depth Phosphoproteome Analysis
Albuquerque, C. P., Smolka, M. B., Payne, S. H., Bafna, V., Eng, J., & Zhou, H. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700468-mcp200 · Cited by 504
Cited by
Quantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
Isobaric Labeling-Based Relative Quantification in Shotgun Proteomics
Rauniyar, N., & Yates, J. R. (2014) · Journal of Proteome Research · doi:10.1021/pr500880b · Cited by 596
An insight into iTRAQ: where do we stand now?
Evans, C., Noirel, J., Ow, S. Y., Salim, M., Pereira-Medrano, A. G., Couto, N., Pandhal, J., Smith, D., Pham, T. K., Karunakaran, E., et al. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5918-6 · Cited by 300
High Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
LeDuc, R. D., Fellers, R. T., Early, B. P., Greer, J. B., Thomas, P. M., & Kelleher, N. L. (2014) · Journal of Proteome Research · doi:10.1021/pr401277r · Cited by 85
Metadata
- Authors
- Wu, J., Warren, P., Shakey, Q., Sousa, E., Hill, A., Ryan, T. E., & He, T.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2010-05-31
- Volume
- 10
- Issue
- 11
- Pages
- 2224-2234
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W1999692740
- Cited by
- 36
- References
- 4
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integrating titania enrichment, iTRAQ labeling, and Orbitrap CID‐HCD for global identification and quantitative analysis of phosphopeptides. https://app.cochat.ai/papers/10.1002/pmic.200900788
- The paper
- Wu, J., Warren, P., Shakey, Q., Sousa, E., Hill, A., Ryan, T. E., & He, T. (2010). Integrating titania enrichment, iTRAQ labeling, and Orbitrap CID‐HCD for global identification and quantitative analysis of phosphopeptides. PROTEOMICS. https://doi.org/10.1002/pmic.200900788
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.