Achievements and perspectives of top‐down proteomics
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Over the last years, top‐down (TD) MS has gained a remarkable space in proteomics, rapidly trespassing the limit between a promising approach and a solid, established technique. Several research groups worldwide have implemented TD analysis in their routine work on proteomics, deriving structural information on proteins with the level of accuracy that is impossible to achieve with classical bottom‐up approaches. Complete maps of PTMs and assessment of single aminoacid polymorphisms are only a few of the results that can be obtained with this technique. Despite some existing technical and economical limitations, TD analysis is at present the most powerful instrument for MS‐based proteomics and its implementation in routine workflow is a rapidly approaching turning point in proteomics. In this review article, the state‐of‐the‐art of TD approach is described along with its major advantages and drawbacks and the most recent trends in TD analysis are discussed. References for all the covered topics are reported in the text, with the aim to support both newcomers and mass spectrometrists already introduced to TD proteomics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Decoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503 · cited 1×
“At present, TD proteomics suffers from a sensitivity issue, due to the fact that, as mentioned above, the ion counts for a single TD fragmentation event is generally low, so that for complex proteomes the amount of sample required for TD may be ten or even 100-fold that is required for shotgun BU experiments [61]”
BackgroundExtending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328 · cited 1×
“In 2006 a combination of nozzle-skimmer voltages, increased capillary temperatures and chemical addictives to ESI solutions allowed the McLafferty group to extend the limits of TD to proteins above 200 kDa [75], with 70% of total amidic bonds cleaved.”
BackgroundZamdborg, L., LeDuc, R. D., Glowacz, K. J., Kim, Y.-B., Viswanathan, V., Spaulding, I. T., Early, B. P., Bluhm, E. J., Babai, S., & Kelleher, N. L. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm371 · Cited by 251
Tran, J. C., & Doucette, A. A. (2008) · Analytical Chemistry · doi:10.1021/ac702197w · Cited by 206 · cited 1×
“Recently a gel-eluted liquid fraction entrapment electrophoresis protocol for protein fractionation using a continuous elution tube gel was published [21, 22] and it seems to be useful to overcome some of these issues.”
MethodProcessing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry
Meng, F., Cargile, B. J., Patrie, S. M., Johnson, J. R., McLoughlin, S. M., & Kelleher, N. L. (2002) · Analytical Chemistry · doi:10.1021/ac020049i · Cited by 183
Patrie, S. M., Ferguson, J. T., Robinson, D. E., Whipple, D., Rother, M., Metcalf, W. W., & Kelleher, N. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500219-mcp200 · Cited by 62
Cited by
Prebiotic Systems Chemistry: New Perspectives for the Origins of Life
Ruiz-Mirazo, K., Briones, C., & de la Escosura, A. (2014) · Chemical Reviews · doi:10.1021/cr2004844 · Cited by 930
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
Photodissociation mass spectrometry: new tools for characterization of biological molecules
Brodbelt, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60444f · Cited by 322
Top‐down proteomics in health and disease: Challenges and opportunities
Gregorich, Z. R., & Ge, Y. (2014) · PROTEOMICS · doi:10.1002/pmic.201300432 · Cited by 217
Identification and Quantification of Proteoforms by Mass Spectrometry
Schaffer, L. V., Millikin, R. J., Miller, R. M., Anderson, L. C., Fellers, R. T., Ge, Y., Kelleher, N. L., LeDuc, R. D., Liu, X., Payne, S. H., et al. (2019) · PROTEOMICS · doi:10.1002/pmic.201800361 · Cited by 209
Zhang, J., Guy, M. J., Norman, H. S., Chen, Y.-C., Xu, Q., Dong, X., Guner, H., Wang, S., Kohmoto, T., Young, K. H., et al. (2011) · Journal of Proteome Research · doi:10.1021/pr200258m · Cited by 194
Online Hydrophobic Interaction Chromatography–Mass Spectrometry for Top-Down Proteomics
Chen, B., Peng, Y., Valeja, S. G., Xiu, L., Alpert, A. J., & Ge, Y. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04285 · Cited by 110
Sen, M. K., Almuslehi, M. S. M., Gyengesi, E., Myers, S. J., Shortland, P. J., Mahns, D. A., & Coorssen, J. R. (2019) · Cells · doi:10.3390/cells8111314 · Cited by 35
Melby, J. A., Jin, Y., Lin, Z., Tucholski, T., Wu, Z., Gregorich, Z. R., Diffee, G. M., & Ge, Y. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00623 · Cited by 20
Metadata
- Authors
- Armirotti, A., & Damonte, G.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2010-08-02
- Volume
- 10
- Issue
- 20
- Pages
- 3566-3576
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2067978791
- Cited by
- 95
- References
- 6
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.