High‐efficiency nano‐ and micro‐HPLC – High‐resolution Orbitrap‐MS platform for top‐down proteomics
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In terms of resolution, mass accuracy, and sensitivity, the Orbitrap represents one of the most potent mass analyzers available today. We here elucidate the potential of interfacing Orbitrap‐MS to ion‐pair RP HPLC for intact protein analysis. Using gradients of ACN and monolithic columns of 1.0 and 0.10 mm id, peak capacities between 120 and 130 were achievable within 20–25 min separation time. Compared with silica‐based stationary phases, protein recovery and carryover from monolithic columns were found clearly superior. Intact proteins were detectable in a mass range covering 5.7–150 kDa with LODs in the low femtomol range. Compared with UV detection, MS detection with a scanning speed of 1.6 s per spectrum on average led to a 26% increase in chromatographic peak widths, whereas chromatographic patterns were mostly preserved in extracted ion chromatograms at an acquisition rate of 0.5 s per spectrum. Isotopic resolution of multiply charged ions was demonstrated for proteins up to 42 kDa. A micro‐HPLC‐Orbitrap‐MS setup employing a 1.0 mm id column was utilized to characterize a 150 kDa recombinant monoclonal antibody. The applicability of nano‐HPLC‐Orbitrap‐MS to the analysis of highly complex protein mixtures is demonstrated for the 70% ethanol extractable subproteome of wheat grains.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370 · cited 1×
“been pushed forward in the past years by the development of protein fragmentation methods based on CID [13], infrared multiphoton dissociation [14], electron-capture dissociation [15, 16], and electron-transfer dissociation [17] as well as by gas phase chemistry enabling charge-state manipulation of multiply charged p…”
MethodSenko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451 · cited 1×
“It subsequently deconvolutes all signals related to a series of multiply charged ions into a spectrum of the uncharged protein and determines the monoisotopic mass by matching the measured isotope pattern to a calculated isotope pattern obtained from the elemental composition of an average hypothetical amino acid (ave…”
BackgroundZamdborg, L., LeDuc, R. D., Glowacz, K. J., Kim, Y.-B., Viswanathan, V., Spaulding, I. T., Early, B. P., Bluhm, E. J., Babai, S., & Kelleher, N. L. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm371 · Cited by 251
Dynamics of ions of intact proteins in the Orbitrap mass analyzer
Makarov, A., & Denisov, E. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.03.024 · Cited by 194 · cited 2×
“Isotopic resolution was demonstrated for multiply charged protein ions up to 30 kDa [27], and, with a modified commercial Orbitrap mass spectrometer, even up to 78 kDa [25].”
BackgroundMethod
Cited by
Fekete, S., Veuthey, J.-L., & Guillarme, D. (2012) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2012.03.024 · Cited by 160
Shen, Y., Tolić, N., Piehowski, P. D., Shukla, A. K., Kim, S., Zhao, R., Qu, Y., Robinson, E., Smith, R. D., & Paša-Tolić, L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.01.008 · Cited by 63
Lakshmanan, R., Wolff, J. J., Alvarado, R., & Loo, J. A. (2014) · PROTEOMICS · doi:10.1002/pmic.201300339 · Cited by 24
Simone, P., Pierri, G., Foglia, P., Gasparrini, F., Mazzoccanti, G., Capriotti, A. L., Ursini, O., Ciogli, A., & Laganà, A. (2016) · Journal of Separation Science · doi:10.1002/jssc.201500844 · Cited by 24
Metadata
- Authors
- Mohr, J., Swart, R., Samonig, M., Böhm, G., & Huber, C. G.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2010-09-21
- Volume
- 10
- Issue
- 20
- Pages
- 3598-3609
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2043859177
- Cited by
- 46
- References
- 4
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐efficiency nano‐ and micro‐HPLC – High‐resolution Orbitrap‐MS platform for top‐down proteomics. https://app.cochat.ai/papers/10.1002/pmic.201000341
- The paper
- Mohr, J., Swart, R., Samonig, M., Böhm, G., & Huber, C. G. (2010). High‐efficiency nano‐ and micro‐HPLC – High‐resolution Orbitrap‐MS platform for top‐down proteomics. PROTEOMICS. https://doi.org/10.1002/pmic.201000341
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.