CoChat

High‐efficiency nano‐ and micro‐HPLC – High‐resolution Orbitrap‐MS platform for top‐down proteomics

Mohr, Jens, Swart, Remco, Samonig, Martin, Böhm, Günter, Huber, Christian G. · 2010 · PROTEOMICS
Cited by 46

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

In terms of resolution, mass accuracy, and sensitivity, the Orbitrap represents one of the most potent mass analyzers available today. We here elucidate the potential of interfacing Orbitrap‐MS to ion‐pair RP HPLC for intact protein analysis. Using gradients of ACN and monolithic columns of 1.0 and 0.10 mm id, peak capacities between 120 and 130 were achievable within 20–25 min separation time. Compared with silica‐based stationary phases, protein recovery and carryover from monolithic columns were found clearly superior. Intact proteins were detectable in a mass range covering 5.7–150 kDa with LODs in the low femtomol range. Compared with UV detection, MS detection with a scanning speed of 1.6 s per spectrum on average led to a 26% increase in chromatographic peak widths, whereas chromatographic patterns were mostly preserved in extracted ion chromatograms at an acquisition rate of 0.5 s per spectrum. Isotopic resolution of multiply charged ions was demonstrated for proteins up to 42 kDa. A micro‐HPLC‐Orbitrap‐MS setup employing a 1.0 mm id column was utilized to characterize a 150 kDa recombinant monoclonal antibody. The applicability of nano‐HPLC‐Orbitrap‐MS to the analysis of highly complex protein mixtures is demonstrated for the 70% ethanol extractable subproteome of wheat grains.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/pmic.201000341

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 46

Metadata

Authors
Mohr, J., Swart, R., Samonig, M., Böhm, G., & Huber, C. G.
Venue
PROTEOMICS
Publisher
Wiley
Published
2010-09-21
Volume
10
Issue
20
Pages
3598-3609
ISSN
  • 1615-9853 (ISSN-L)
  • 1615-9861
OpenAlex
W2043859177
Cited by
46
References
4
FWCI
2.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High‐efficiency nano‐ and micro‐HPLC – High‐resolution Orbitrap‐MS platform for top‐down proteomics. https://app.cochat.ai/papers/10.1002/pmic.201000341
The paper
Mohr, J., Swart, R., Samonig, M., Böhm, G., & Huber, C. G. (2010). High‐efficiency nano‐ and micro‐HPLC – High‐resolution Orbitrap‐MS platform for top‐down proteomics. PROTEOMICS. https://doi.org/10.1002/pmic.201000341

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.