The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Determination of monoisotopic masses and ion populations for large biomolecules from resolved isotopic distributions
Abstract
The coupling of electrospray ionization with Fourier-transform mass spectrometry allows the analysis of large biomolecules with mass-measuring errors of less than 1 ppm. The large number of atoms incorporated in these molecules results in a low probability for the all-monoisotopic species. This produces the potential to misassign the number of heavy isotopes in a specific peak and make a mass error of ±1 Da, although the certainty of the measurement beyond the decimal place is greater than 0.1 Da. Statistical tests are used to compare the measured isotopic distribution with the distribution for a model molecule of the same average molecular mass, which allows the assignment of the monoisotopic mass, even in cases where the monoisotopic peak is absent from the spectrum. The statistical test produces error levels that are inversely proportional to the number of molecules in a distribution, which allows an estimation of the number of ions in the trapped ion cell. It has been determined, via this method that 128 charges are required to produce a signal-to-noise ratio of 3:1, which correlates well with previous experimental methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“THRASH uses a theoretical isotopomer envelope based on the average elemental composition of amino acids (averagine) [125] to compare to the experimental envelopes. A statistical score is then assigned based on the overlap of the experimental and theoretical fit.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [125]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted ultraviolet laser desorption of non-volatile compounds
Karas, M., Bachmann, D., Bahr, U., & Hillenkamp, F. (1987) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(87)87041-6 · Cited by 1,953
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
High-resolution electrospray mass spectra of large molecules
Henry, K. D., Quinn, J. P., & McLafferty, F. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00014a043 · Cited by 309
Loo, J. A., Udseth, H. R., & Smith, R. D. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90153-x · Cited by 264
A general approach to calculating isotopic distributions for mass spectrometry
Yergey, J. A. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)85053-0 · Cited by 222
Fourier-transform mass spectrometry of large molecules by electrospray ionization.
Henry, K. D., Williams, E. R., Wang, B. H., McLafferty, F. W., Shabanowitz, J., & Hunt, D. F. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.23.9075 · Cited by 215
Loo, J. A., Edmonds, C. G., & Smith, R. D. (1991) · Analytical Chemistry · doi:10.1021/ac00021a018 · Cited by 189
Research works printed but not linked: 2
- Teer D., 1975, J. Polym. Sci., 13, 985
- 10.1021/ac00024a002 · DOI · Paper page
Cited by
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855
“An edge is inserted between two peaks when the difference in mass equals the difference in isotope mass of an average amino acid ('averagine”
BackgroundAndromeda: A Peptide Search Engine Integrated into the MaxQuant Environment
Cox, J., Neuhauser, N., Michalski, A., Scheltema, R. A., Olsen, J. V., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101065j · Cited by 5,500
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
“1985, 18, 316–322. sition (Senko et al., 1995).”
mMass 3: A Cross-Platform Software Environment for Precise Analysis of Mass Spectrometric Data
Strohalm, M., Kavan, D., Novák, P., Volný, M., & Havlíček, V. (2010) · Analytical Chemistry · doi:10.1021/ac100818g · Cited by 806
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Metadata
- Authors
- Senko, M. W., Beu, S. C., & McLaffertycor, F. W.
- Affiliations
- Cornell University (US)
- ORCID
- Senko, Michael W.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-04-01
- Volume
- 6
- Issue
- 4
- Pages
- 229-233
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2086502504
- Cited by
- 451
- References
- 24
- Citations by year
- 2026: 12 · 2025: 14 · 2024: 19 · 2023: 12 · 2022: 11 · 2021: 19 · 2020: 28 · 2019: 18 · 2018: 16 · 2017: 23 · 2016: 20 · 2015: 17 · 2014: 21 · 2013: 22 · 2012: 15
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- isotopic distribution, large biomolecules, electrospray ionization, Fourier transform mass spectrometry, statistical tests, signal-to-noise ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of monoisotopic masses and ion populations for large biomolecules from resolved isotopic distributions. https://app.cochat.ai/papers/10.1016/1044-0305(95)00017-8
- The paper
- Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995). Determination of monoisotopic masses and ion populations for large biomolecules from resolved isotopic distributions. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/1044-0305(95)00017-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.