Effect of mass spectrometric parameters on peptide and protein identification rates for shotgun proteomic experiments on an LTQ‐orbitrap mass analyzer
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The success of a shotgun proteomic experiment relies heavily on the performance and optimization of both the LC and the MS systems. Despite this, little consideration has, so far, been given to the importance of evaluating and optimizing the MS instrument settings during data‐dependent acquisition mode. Moreover, during data‐dependent acquisition, the users have to decide and choose among various MS parameters and settings, making a successful analysis even more challenging. We have systematically investigated and evaluated the effect of enabling and disabling the preview mode for FTMS scan, the number of microscans per MS/MS scan, the number of MS/MS events, the maximum ion injection time for MS/MS, and the automatic gain control target value for MS and MS/MS events on protein and peptide identification rates on an LTQ‐Orbitrap using the Saccharomyces cerevisiae proteome. Our investigations aimed to assess the significance of each MS parameter to improve proteome analysis and coverage. We observed that higher identification rates were obtained at lower ion injection times i.e. 50–150 ms, by performing one microscan and 12–15 MS/MS events. In terms of ion population, optimal automatic gain control target values were at 5×10 5–1×10 6 ions for MS and 3×10 3–1×10 4 ions for MS/MS. The preview mode scan had a minimal effect on identification rates. Using optimized MS settings, we identified 1038 (±2.3%) protein groups with a minimum of two peptide identifications and an estimated false discovery rate of ∼1% at both peptide and protein level in a 160‐min LC‐MS/MS analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tabb, D. L., Vega-Montoto, L., Rudnick, P. A., Variyath, A. M., Ham, A.-J. L., Bunk, D. M., Kilpatrick, L. E., Billheimer, D. D., Blackman, R. K., Cardasis, H. L., et al. (2010) · Journal of Proteome Research · doi:10.1021/pr9006365 · Cited by 551
Graumann, J., Hubner, N. C., Kim, J. B., Ko, K., Moser, M., Kumar, C., Cox, J., Schöler, H., & Mann, M. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700460-mcp200 · Cited by 275
Rudnick, P. A., Clauser, K. R., Kilpatrick, L. E., Tchekhovskoi, D. V., Neta, P., Blonder, N., Billheimer, D. D., Blackman, R. K., Bunk, D. M., Cardasis, H. L., et al. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900223-mcp200 · Cited by 183
Cited by
The Xist lncRNA interacts directly with SHARP to silence transcription through HDAC3
McHugh, C. A., Chen, C.-K., Chow, A., Surka, C. F., Tran, C., McDonel, P., Pandya-Jones, A., Blanco, M., Burghard, C., Moradian, A., et al. (2015) · Nature · doi:10.1038/nature14443 · Cited by 1,159
Self-citationWiemann, P., Sieber, C. M. K., von Bargen, K. W., Studt, L., Niehaus, E.-M., Espino, J. J., Huß, K., Michielse, C. B., Albermann, S., Wagner, D., et al. (2013) · PLoS Pathogens · doi:10.1371/journal.ppat.1003475 · Cited by 463
Capillary zone electrophoresis-mass spectrometry for bottom-up proteomics
Zhang, Z., Qu, Y., & Dovichi, N. J. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.08.008 · Cited by 61
Zhang, Z., & Dovichi, N. J. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.023 · Cited by 20
Claesen, J., Lermyte, F., Sobott, F., Burzykowski, T., & Valkenborg, D. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01165 · Cited by 9
Metadata
- Authors
- Kalli, A., & Hess, S.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2011-11-29
- Volume
- 12
- Issue
- 1
- Pages
- 21-31
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2071352806
- Cited by
- 55
- References
- 3
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of mass spectrometric parameters on peptide and protein identification rates for shotgun proteomic experiments on an LTQ‐orbitrap mass analyzer. https://app.cochat.ai/papers/10.1002/pmic.201100464
- The paper
- Kalli, A., & Hess, S. (2012). Effect of mass spectrometric parameters on peptide and protein identification rates for shotgun proteomic experiments on an LTQ‐orbitrap mass analyzer. PROTEOMICS. https://doi.org/10.1002/pmic.201100464
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.